Literature DB >> 14501505

Laparoscopic repair of ventral hernias: nine years' experience with 850 consecutive hernias.

B Todd Heniford1, Adrian Park, Bruce J Ramshaw, Guy Voeller.   

Abstract

OBJECTIVE: To evaluate the efficacy and safety of laparoscopic repair of ventral hernias. SUMMARY BACKGROUND DATA: The recurrence rate after standard repair of ventral hernias may be as high as 12-52%, and the wide surgical dissection required often results in wound complications. Use of a laparoscopic approach may decrease rates of complications and recurrence after ventral hernia repair.
METHODS: Data on all patients who underwent laparoscopic ventral hernia repair (LVHR) performed by 4 surgeons using a standardized procedure between November 1993 and October 2002 were collected prospectively (85% of patients) or retrospectively.
RESULTS: LVHR was completed in 819 of the 850 patients (422 men; 428 women) in whom it was attempted. Thirty-four percent of completed LVHRs were for recurrent hernias. The patient mean body mass index was 32; the mean defect size was 118 cm2. Mesh, averaging 344 cm2, was used in all cases. Mean operating time was 120 min, mean estimated blood loss was 49 mL, and hospital stay averaged 2.3 days. There were 128 complications in 112 patients (13.2%). One patient died of a myocardial infarction. The most common complications were ileus (3%) and prolonged seroma (2.6%). During a mean follow-up time of 20.2 months (range, 1-94 months), the hernia recurrence rate was 4.7%. Recurrence was associated with large defects, obesity, previous open repairs, and perioperative complications.
CONCLUSION: In this large series, LVHR had a low rate of conversion to open surgery, a short hospital stay, a moderate complication rate, and a low risk of recurrence.

Entities:  

Mesh:

Year:  2003        PMID: 14501505      PMCID: PMC1422707          DOI: 10.1097/01.sla.0000086662.49499.ab

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  37 in total

1.  Laparoscopic incisional and ventral herniorraphy: our initial 100 patients.

Authors:  K A LeBlanc; W V Booth; J M Whitaker; D E Bellanger
Journal:  Hernia       Date:  2001-03       Impact factor: 4.739

2.  A comparison of suture repair with mesh repair for incisional hernia.

Authors:  R W Luijendijk; W C Hop; M P van den Tol; D C de Lange; M M Braaksma; J N IJzermans; R U Boelhouwer; B C de Vries; M K Salu; J C Wereldsma; C M Bruijninckx; J Jeekel
Journal:  N Engl J Med       Date:  2000-08-10       Impact factor: 91.245

3.  Laparoscopic ventral and incisional hernia repair in 407 patients.

Authors:  B T Heniford; A Park; B J Ramshaw; G Voeller
Journal:  J Am Coll Surg       Date:  2000-06       Impact factor: 6.113

4.  Laparoscopic intraperitoneal polytetrafluoroethylene (PTFE) prosthetic patch repair of ventral hernia. Prospective comparison to open prefascial polypropylene mesh repair.

Authors:  E J DeMaria; J M Moss; H J Sugerman
Journal:  Surg Endosc       Date:  2000-04       Impact factor: 4.584

5.  Comparison of laparoscopic and open ventral herniorrhaphy.

Authors:  B J Ramshaw; P Esartia; J Schwab; E M Mason; R A Wilson; T D Duncan; J Miller; G W Lucas; J Promes
Journal:  Am Surg       Date:  1999-09       Impact factor: 0.688

6.  Laparoscopic ventral hernia repair: are there comparative advantages over traditional methods of repair?

Authors:  Byron E Wright; Brian D Niskanen; Debra J Peterson; Arthur L Ney; Mark D Odland; Joan VanCamp; Richard T Zera; Jorge L Rodriguez
Journal:  Am Surg       Date:  2002-03       Impact factor: 0.688

7.  Laparoscopic treatment vs open surgery in the solution of major incisional and abdominal wall hernias with mesh.

Authors:  M A Carbajo; J C Martín del Olmo; J I Blanco; C de la Cuesta; M Toledano; F Martin; C Vaquero; L Inglada
Journal:  Surg Endosc       Date:  1999-03       Impact factor: 4.584

8.  Laparoscopic ventral and incisional hernia repair.

Authors:  M E Franklin; J P Dorman; J L Glass; J E Balli; J J Gonzalez
Journal:  Surg Laparosc Endosc       Date:  1998-08

9.  Laparoscopic repair of recurrent ventral hernias.

Authors:  M J Costanza; B T Heniford; M J Arca; J T Mayes; M Gagner
Journal:  Am Surg       Date:  1998-12       Impact factor: 0.688

10.  Prospective, multicenter study of laparoscopic ventral hernioplasty. Preliminary results.

Authors:  F K Toy; R W Bailey; S Carey; C W Chappuis; M Gagner; L G Josephs; E C Mangiante; A E Park; A Pomp; R T Smoot; J F Uddo; G R Voeller
Journal:  Surg Endosc       Date:  1998-07       Impact factor: 4.584

View more
  279 in total

1.  Histologic and biomechanical evaluation of a novel macroporous polytetrafluoroethylene knit mesh compared to lightweight and heavyweight polypropylene mesh in a porcine model of ventral incisional hernia repair.

Authors:  L Melman; E D Jenkins; N A Hamilton; L C Bender; M D Brodt; C R Deeken; S C Greco; M M Frisella; B D Matthews
Journal:  Hernia       Date:  2011-01-30       Impact factor: 4.739

2.  Comparison of two composite meshes using two fixation devices in a porcine laparoscopic ventral hernia repair model.

Authors:  A J Duffy; N J Hogle; K M LaPerle; D L Fowler
Journal:  Hernia       Date:  2004-12       Impact factor: 4.739

3.  Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model.

Authors:  C Schug-Pass; H Lippert; F Köckerling
Journal:  Surg Endosc       Date:  2009-05-23       Impact factor: 4.584

4.  Mesh fixation with a barbed anchor suture results in significantly less strangulation of the abdominal wall.

Authors:  Calvin Lyons; Rohan Joseph; Nilson Salas; Patrick R Reardon; Barbara L Bass; Brian J Dunkin
Journal:  Surg Endosc       Date:  2011-11-15       Impact factor: 4.584

5.  Evaluation of acute fixation strength of absorbable and nonabsorbable barrier coated mesh secured with fibrin sealant.

Authors:  E D Jenkins; L Melman; M M Frisella; C R Deeken; B D Matthews
Journal:  Hernia       Date:  2010-05-09       Impact factor: 4.739

6.  Biocompatibility and tissue integration of a novel shape memory surgical mesh for ventral hernia: in vivo animal studies.

Authors:  Michael M Zimkowski; Mark E Rentschler; Jonathan A Schoen; Nageswara Mandava; Robin Shandas
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-12-10       Impact factor: 3.368

7.  Evaluation of port site hernias, chronic pain and recurrence rates after laparoscopic ventral hernia repair: a monocentric long-term study.

Authors:  Emilie Liot; Romain Bréguet; Valérie Piguet; Frédéric Ris; Francesco Volonté; Philippe Morel
Journal:  Hernia       Date:  2017-09-01       Impact factor: 4.739

8.  Laparoscopic parastomal hernia repair.

Authors:  R O Craft; K L Huguet; E C McLemore; K L Harold
Journal:  Hernia       Date:  2007-11-13       Impact factor: 4.739

9.  History of methicillin-resistant Staphylococcus aureus (MRSA) surgical site infection may not be a contraindication to ventral hernia repair with synthetic mesh: a preliminary report.

Authors:  C W Hicks; J A Blatnik; D M Krpata; Y W Novitsky; M J Rosen
Journal:  Hernia       Date:  2013-01-18       Impact factor: 4.739

Review 10.  [Intervention-specific complications of hernia surgery].

Authors:  U A Dietz; A Wiegering; C T Germer
Journal:  Chirurg       Date:  2014-02       Impact factor: 0.955

View more