The reliability of a simulated uphill time trial using the Velotron electronic bicycle ergometer.

Eric E Noreen1, Kathyrn Yamamoto, Kelli Clair.   

Abstract

This study was conducted to measure the reliability of an indoor uphill time trial (TT) using the Velotron electronic bicycle ergometer with a computer-generated pacer that represented a subject's prior TT performance. A total of 12 trained cyclists (42 ± 7.79 years, 63.0 ± 6.12 ml/kg/min) completed three 8-mile uphill TT with 2-7 days between subsequent tests. A repeated measure ANOVA found no difference between finishing times for TT1 (2,154 ± 246 s) and TT2 (2,078 ± 185 s, p = 0.055) or TT2 and TT3 (2,047 ± 167 s, p = 0.075). All measures of reliability showed an increased reliability for finishing times in TT2-TT3 [95% CI for: coefficient of variation (CV) = 1.0-2.3%, intraclass correlation coefficient (ICC) = 0.953-0.996, standard error of measurement (SEM) = 2.1-4.9 s] versus TT1-TT2 (95% CI for: CV = 2.0-4.9%, ICC = 0.827-0.986, SEM = 9.8-23 s). An uphill TT using the Velotron bicycle ergometer with a prior performance as a pacer is a reliable assessment for indoor TT performance testing, but a familiarization trial improves reliability. Although there were no significant differences found for completion times between TT1-TT2 or TT2-TT3, the absolute mean differences, small sample size and low p values may be suggestive of a Type II error.

Entities:  

Mesh:

Year:  2010        PMID: 20526613     DOI: 10.1007/s00421-010-1501-z

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  22 in total

1.  The validity of power output recorded during exercise performance tests using a Kingcycle air-braked cycle ergometer when compared with an SRM powermeter.

Authors:  J Balmer; R C Davison; D A Coleman; S R Bird
Journal:  Int J Sports Med       Date:  2000-04       Impact factor: 3.118

2.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

3.  Day to day variation in time trial cycling performance.

Authors:  M S Hickey; D L Costill; G K McConell; J J Widrick; H Tanaka
Journal:  Int J Sports Med       Date:  1992-08       Impact factor: 3.118

4.  Reproducibility of a laboratory based 20-km time trial evaluation in competitive cyclists using the Velotron Pro ergometer.

Authors:  B C Sporer; D C McKenzie
Journal:  Int J Sports Med       Date:  2007-05-11       Impact factor: 3.118

5.  Assessment of the reproducibility of performance testing on an air-braked cycle ergometer.

Authors:  G S Palmer; S C Dennis; T D Noakes; J A Hawley
Journal:  Int J Sports Med       Date:  1996-05       Impact factor: 3.118

Review 6.  Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine.

Authors:  G Atkinson; A M Nevill
Journal:  Sports Med       Date:  1998-10       Impact factor: 11.136

7.  A new reliable laboratory test of endurance performance for road cyclists.

Authors:  E J Schabort; J A Hawley; W G Hopkins; I Mujika; T D Noakes
Journal:  Med Sci Sports Exerc       Date:  1998-12       Impact factor: 5.411

8.  A new validated endurance performance test.

Authors:  A Jeukendrup; W H Saris; F Brouns; A D Kester
Journal:  Med Sci Sports Exerc       Date:  1996-02       Impact factor: 5.411

9.  Reliability of air displacement plethysmography in a large, heterogeneous sample.

Authors:  Eric E Noreen; Peter W R Lemon
Journal:  Med Sci Sports Exerc       Date:  2006-08       Impact factor: 5.411

10.  Variability of time to exhaustion during submaximal exercise.

Authors:  T M McLellan; S S Cheung; I Jacobs
Journal:  Can J Appl Physiol       Date:  1995-03
View more
  3 in total

1.  Deception Improves Time Trial Performance in Well-trained Cyclists without Augmented Fatigue.

Authors:  Paul Ansdell; Kevin Thomas; Glyn Howatson; Markus Amann; Stuart Goodall
Journal:  Med Sci Sports Exerc       Date:  2018-04       Impact factor: 5.411

2.  Familiarization Protocol Influences Reproducibility of 20-km Cycling Time-Trial Performance in Novice Participants.

Authors:  Andrew W Hibbert; François Billaut; Matthew C Varley; Remco C J Polman
Journal:  Front Physiol       Date:  2017-07-20       Impact factor: 4.566

3.  Effect of a Flying Versus Stationary Start on Wingate Test Outcomes Using an Electromagnetically-Braked Cycle Ergometer in Advanced Resistance-Trained Males.

Authors:  Nicolas W Clark; Dale R Wagner; Edward M Heath
Journal:  Int J Exerc Sci       Date:  2018-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.