Clinical application of C2 laminar screw technique.

Weihu Ma1, Leling Feng, Rongming Xu, Xiaochen Liu, Alan H Lee, Shaohua Sun, Liujun Zhao, Yong Hu, Guanyi Liu.   

Abstract

C2 laminar screws have become an increasingly used alternative method to C2 pedicle screw fixation. However, the outcome of this technique has not been thoroughly investigated. A total of 35 cases with upper cervical spinal instability undergoing C2 laminar screw fixation were reviewed. All cases had symptoms of atlantoaxial instability, such as craniocervical junction pain, and were fixed with the Vertex cervical internal fixation system. A total of 68 screws were placed and hybrid constructs (a C2 translaminar screw combined with a C2 pars screw) were incorporated in two patients. In this series, there were no intraoperative complications and no cases of neurological worsening or vascular injury from hardware placement. Computed tomographic scans demonstrated a partial dorsal laminar breach in ten patients. None of these resulted in neurological symptoms. None of the patients was found to have a breach of the ventral laminar cortex. All the C2 laminar screws fixations were performed successfully. There was no instability seen on the films with no evidence of hardware failure or screw loosening during the follow-up period in all patients. In conclusion, C2 laminar screw technique is straightforward and easily adopted; it can efficiently and reliably restore upper cervical stability. It is an alternative method to C2 pedicle screw fixation, especially in patients with unilateral occlusion of vertebral artery and pedicle deformity of C2.

Entities:  

Mesh:

Year:  2010        PMID: 20524135      PMCID: PMC2989209          DOI: 10.1007/s00586-010-1447-1

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  15 in total

1.  Anatomic study of the axis for surgical planning of transarticular screw fixation.

Authors:  Tamaki Igarashi; Shinichi Kikuchi; Katsuhiko Sato; Satoru Kayama; Koji Otani
Journal:  Clin Orthop Relat Res       Date:  2003-03       Impact factor: 4.176

2.  Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note.

Authors:  Neill M Wright
Journal:  J Spinal Disord Tech       Date:  2004-04

3.  Biomechanical evaluation of four different posterior atlantoaxial fixation techniques.

Authors:  D Grob; J J Crisco; M M Panjabi; P Wang; J Dvorak
Journal:  Spine (Phila Pa 1976)       Date:  1992-05       Impact factor: 3.468

4.  Atlantoaxial stabilization: clinical comparison of posterior cervical wiring technique with transarticular screw fixation.

Authors:  Thomas M Reilly; Rick C Sasso; Peter V Hall
Journal:  J Spinal Disord Tech       Date:  2003-06

5.  Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass.

Authors:  Mingsheng Tan; Huimin Wang; Yunting Wang; Guangbo Zhang; Ping Yi; Zirong Li; Hongyu Wei; Feng Yang
Journal:  Spine (Phila Pa 1976)       Date:  2003-05-01       Impact factor: 3.468

6.  Anatomic consideration of C2 pedicle screw placement.

Authors:  N Ebraheim; J R Rollins; R Xu; W T Jackson
Journal:  Spine (Phila Pa 1976)       Date:  1996-03-15       Impact factor: 3.468

7.  Posterior C1-C2 fusion with polyaxial screw and rod fixation.

Authors:  J Harms; R P Melcher
Journal:  Spine (Phila Pa 1976)       Date:  2001-11-15       Impact factor: 3.468

Review 8.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Authors:  N M Wright; C Lauryssen
Journal:  J Neurosurg       Date:  1998-04       Impact factor: 5.115

9.  Cervical crossing laminar screws: early clinical results and complications.

Authors:  Michael Y Wang
Journal:  Neurosurgery       Date:  2007-11       Impact factor: 4.654

10.  Primary posterior fusion C1/2 in odontoid fractures: indications, technique, and results of transarticular screw fixation.

Authors:  B Jeanneret; F Magerl
Journal:  J Spinal Disord       Date:  1992-12
View more
  13 in total

Review 1.  Use of intraoperative fluoroscopy for the safe placement of C2 laminar screws: technical note.

Authors:  John A Engler; Michael L Smith
Journal:  Eur Spine J       Date:  2015-08-05       Impact factor: 3.134

2.  The options of C2 fixation for os odontoideum: a radiographic study for the C2 pedicle and lamina anatomy.

Authors:  Xian-zhong Meng; Jia-xin Xu
Journal:  Eur Spine J       Date:  2011-07-03       Impact factor: 3.134

3.  Posterior C1-C2 screw and rod instrument for reduction and fixation of basilar invagination with atlantoaxial dislocation.

Authors:  Sheng Li Guo; Ding Biao Zhou; Xin Guang Yu; Yi Heng Yin; Guang Yu Qiao
Journal:  Eur Spine J       Date:  2014-06-18       Impact factor: 3.134

4.  Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study.

Authors:  Yong Hu; Zhen-shan Yuan; William Ryan Spiker; Todd J Albert; Wei-xin Dong; Hui Xie; Jian-bing Yuan; Cheng-tao Wang
Journal:  Eur Spine J       Date:  2013-09-05       Impact factor: 3.134

5.  Translaminar screws of the axis--an alternative technique for rigid screw fixation in upper cervical spine instability.

Authors:  D Meyer; F Meyer; Th Kretschmer; W Börm
Journal:  Neurosurg Rev       Date:  2011-11-17       Impact factor: 3.042

6.  The reinforcement of a C2 laminar screw by a C2 laminar hook as an anchor of occipito-C2 fusion.

Authors:  Masashi Neo; Hiroyuki Yoshitomi; Mitsuru Takemoto; Masanori Izeki
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-10-27

7.  Occipitocervical instrumented fixation utilising patient-specific C2 3D-printed spinal screw trajectory guides in complex paediatric skeletal dysplasia.

Authors:  Vejay N Vakharia; Luke Smith; Zubair Tahir; Rachel Sparks; Sebastien Ourselin; Stewart Tucker; Dominic Thompson
Journal:  Childs Nerv Syst       Date:  2021-06-19       Impact factor: 1.475

8.  C1-C2 fusion: postoperative C2 nerve impingement-is it a problem?

Authors:  Kurt D Myers; Emily M Lindley; Evalina L Burger; Vikas V Patel
Journal:  Evid Based Spine Care J       Date:  2012-02

9.  Comparison between Bilateral C2 Pedicle Screwing and Unilateral C2 Pedicle Screwing, Combined with Contralateral C2 Laminar Screwing, for Atlantoaxial Posterior Fixation.

Authors:  Naohisa Miyakoshi; Michio Hongo; Takashi Kobayashi; Tetsuya Suzuki; Eiji Abe; Yoichi Shimada
Journal:  Asian Spine J       Date:  2014-12-17

10.  Management of post-traumatic craniovertebral junction dislocation: A PRISMA-compliant systematic review and meta-analysis of casereports.

Authors:  Tomasz Klepinowski; Bartosz Limanówka; Leszek Sagan
Journal:  Neurosurg Rev       Date:  2020-08-14       Impact factor: 3.042

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.