Literature DB >> 18091245

Cervical crossing laminar screws: early clinical results and complications.

Michael Y Wang1.   

Abstract

OBJECTIVE: C2 crossing laminar screws are a new technique for axis fixation with a purported lower risk for neurological or vascular injury. However, to date, few clinical series on this technique have appeared in the peer-reviewed literature. This report describes our initial clinical experience and complications using this new spinal fixation technique.
METHODS: Thirty patients underwent high cervical intralaminar fixation with crossing intralaminar screws. Indications for surgery included occiput to cervical fixation for basilar invagination in six patients, fixation for atlantoaxial subluxation or trauma in six patients, cervical swan neck deformity in four patients, and laminectomy and instrumented fusion for cervical stenosis in 14 patients. Two cases involved C3 fixation resulting from congenital anomalies. A total of 59 screws were placed, and the patients were assessed both clinically and radiographically with postoperative computed tomographic scans.
RESULTS: There were no intraoperative complications and no cases of neurological worsening or vascular injury from hardware placement. One patient reported local neck pain resulting from hardware prominence. Computed tomographic scans demonstrated a partial dorsal laminar breach in 11 patients and violation of the spinal canal in one patient. None of these resulted in neurological symptoms. Early hardware fractures were observed in two patients.
CONCLUSION: Crossing C2 laminar screws provide the surgeon with an expanded armamentarium for fixation in the high cervical spine. This technique is straightforward and easily adopted. However, the unique position of the screw heads may result in increased stress and strain on the intralaminar screws. Thus, larger diameter screws or additional fixation points at adjacent levels are recommended.

Entities:  

Mesh:

Year:  2007        PMID: 18091245     DOI: 10.1227/01.neu.0000303987.49870.7b

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  27 in total

1.  C7 posterior fixation using intralaminar screws : early clinical and radiographic outcome.

Authors:  Sang Hoon Jang; Jae Taek Hong; Il Sup Kim; In Sung Yeo; Byung Chul Son; Sang Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2010-08-31

2.  The use of pedicle screw-rod system for the posterior fixation in cervico-thoracic junction.

Authors:  Wonik Cho; Ahmed Shawky Eid; Ung-Kyu Chang
Journal:  J Korean Neurosurg Soc       Date:  2010-07-31

3.  Clinical application of C2 laminar screw technique.

Authors:  Weihu Ma; Leling Feng; Rongming Xu; Xiaochen Liu; Alan H Lee; Shaohua Sun; Liujun Zhao; Yong Hu; Guanyi Liu
Journal:  Eur Spine J       Date:  2010-06-05       Impact factor: 3.134

Review 4.  Use of intraoperative fluoroscopy for the safe placement of C2 laminar screws: technical note.

Authors:  John A Engler; Michael L Smith
Journal:  Eur Spine J       Date:  2015-08-05       Impact factor: 3.134

5.  Modified translaminar screw fixation in the cervicothoracic junction (C7-T2): a technical note.

Authors:  Dong-Dong Xia; Mei-Jun Yan; Jing-Jie Zhang; Feng Zhou; Hong-Ming Xu; Yong-Li Wang; Jun Tan; Xiang-Yang Wang
Journal:  Eur Spine J       Date:  2016-01-30       Impact factor: 3.134

6.  Morphometric trajectory analysis for the C2 crossing laminar screw technique.

Authors:  Bin Yue; Dai-Soon Kwak; Moon-Kyu Kim; Seong-Oh Kwon; Seung-Ho Han
Journal:  Eur Spine J       Date:  2010-02-21       Impact factor: 3.134

Review 7.  Cervical screw placement using rapid prototyping drill templates for navigation: a literature review.

Authors:  Teng Lu; Chao Liu; Jun Dong; Meng Lu; Haopeng Li; Xijing He
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-05-09       Impact factor: 2.924

8.  Computed tomography morphometric analysis of C2 translaminar screw fixation of Wright's technique and a modified technique in the pediatric cervical spine.

Authors:  Dong-Dong Xia; Sheng-Lei Lin; Wei Chen; Zhong-Hai Shen; Yao Li; Xiang-Yang Wang; Hua-Zi Xu; Yong-Long Chi
Journal:  Eur Spine J       Date:  2013-12-12       Impact factor: 3.134

9.  Inferolateral entry point for c2 pedicle screw fixation in high cervical lesions.

Authors:  Kwang Ho Lee; Dong Ho Kang; Chul Hee Lee; Soo Hyun Hwang; In Sung Park; Jin Myung Jung
Journal:  J Korean Neurosurg Soc       Date:  2011-10-31

10.  Deviation analysis of C2 translaminar screw placement assisted by a novel rapid prototyping drill template: a cadaveric study.

Authors:  Yong Hu; Zhen-shan Yuan; William Ryan Spiker; Todd J Albert; Wei-xin Dong; Hui Xie; Jian-bing Yuan; Cheng-tao Wang
Journal:  Eur Spine J       Date:  2013-09-05       Impact factor: 3.134

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.