Prospective study to estimate mandibular cancellous bone density using large-volume cone-beam computed tomography.

Munetaka Naitoh1, Akiko Hirukawa, Akitoshi Katsumata, Eiichiro Ariji.   

Abstract

OBJECTIVE: Because pixel or voxel values obtained from cone-beam computed tomography (CBCT) images are not absolute values, the bone density cannot be evaluated. Hence, the regression line between voxel values of CBCT and the bone mineral density (BMDs) of multislice CT (MSCT) was prospectively evaluated to investigate the mandibular cancellous bone density. Also, the usefulness of a reference bone block was evaluated on assessing a low mandibular bone density.
MATERIALS AND METHODS: A total of 15 (two males and 13 females) patients who had undergone postoperative imaging for mandibular dental implant treatment with a bone graft using CBCT and MSCT were enrolled in this investigation. Voxel values of region of interests in CBCT were transformed to BMDs using a regression line from a previous study, and differences between BMDs obtained using CBCT and MSCT were calculated. Also, the voxel values of CBCT at the selected sites, in which the bone density was measured between 100 and 300 mg/cm(3) of hydroxyapatite (HA) in MSCT, were assessed regarding whether they were higher or lower than the BMD of the reference bone block.
RESULTS: The mean overall difference was 38 mg/cm(3) of HA. Thirty-eight of the 45 sites (84%) were accurately assessed using the reference bone block.
CONCLUSION: The usefulness of a regression line for BMD estimation in CBCT was prospectively confirmed in mandibular cancellous bone. Also, the reference bone block was useful to assess the low bone density of mandibular cancellous bone on CBCT with a large volume.
© 2010 John Wiley & Sons A/S.

Entities:  

Mesh:

Year:  2010        PMID: 20497440     DOI: 10.1111/j.1600-0501.2010.01950.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  13 in total

Review 1.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

2.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

3.  Calibration of cone beam CT using relative attenuation ratio for quantitative assessment of bone density: a small animal study.

Authors:  Yifei Liu; Tobias Bäuerle; Leyun Pan; Antonia Dimitrakopoulou-Strauss; Ludwig G Strauss; Christian Heiss; Reinhard Schnettler; Wolfhard Semmler; Liji Cao
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-08       Impact factor: 2.924

Review 4.  Diagnostic imaging of trabecular bone microstructure for oral implants: a literature review.

Authors:  N Ibrahim; A Parsa; B Hassan; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

5.  Imaging of nano-hydroxyapatite/chitosan scaffolds using a cone beam computed tomography device on rat calvarial defects with histological verification.

Authors:  Emmanouil Chatzipetros; Zafeiroula Yfanti; Panos Christopoulos; Catherine Donta; Spyros Damaskos; Evangelos Tsiambas; Dimitris Tsiourvas; Eleni-Marina Kalogirou; Konstantinos I Tosios; Kostas Tsiklakis
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

6.  Can gray values derived from CT and cone beam CT estimate new bone formation? An in vivo study.

Authors:  Farshid Bastami; Shahriar Shahab; Azin Parsa; Fatemeh Mashhadi Abbas; Mohammad Hadi Noori Kooshki; Mahshid Namdari; Hamidreza Azimi Lisar; Tohid Rafiei; Farahnaz Fahimipour; Majid Salehi; Maissa Jafari
Journal:  Oral Maxillofac Surg       Date:  2017-10-31

7.  Effect of different voxel sizes on the accuracy of CBCT measurements of trabecular bone microstructure: A comparative micro-CT study.

Authors:  Mahmure Ayşe Tayman; Kıvanç Kamburoğlu; Mert Ocak; Doğukan Özen
Journal:  Imaging Sci Dent       Date:  2022-04-28

8.  Variability of dental cone beam CT grey values for density estimations.

Authors:  R Pauwels; O Nackaerts; N Bellaiche; H Stamatakis; K Tsiklakis; A Walker; H Bosmans; R Bogaerts; R Jacobs; K Horner
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

9.  Evaluation of number of roots and root anatomy of permanent mandibular third molars in a Korean population, using cone-beam computed tomography.

Authors:  Jun-Beom Park; NamRyang Kim; Seojin Park; Youngkyung Ko
Journal:  Eur J Dent       Date:  2013-07

10.  Effect of object location on the density measurement in cone-beam computed tomography versus multislice computed tomography.

Authors:  Amir Eskandarloo; Mehrdad Abdinian; Fatemeh Salemi; Zahra Hashemzadeh; Mehran Safaei
Journal:  Dent Res J (Isfahan)       Date:  2012-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.