Literature DB >> 23225074

Calibration of cone beam CT using relative attenuation ratio for quantitative assessment of bone density: a small animal study.

Yifei Liu1, Tobias Bäuerle, Leyun Pan, Antonia Dimitrakopoulou-Strauss, Ludwig G Strauss, Christian Heiss, Reinhard Schnettler, Wolfhard Semmler, Liji Cao.   

Abstract

PURPOSE: Cone beam computed tomography (CBCT) has the disadvantage of providing non-quantitative results for bone density determination. The aim of this study is to calibrate CBCT results by using an internal reference (such as muscle) for quantitatively assessing bone density.
METHODS: We developed a new method using the relative attenuation ratio between two nearby materials (such as bone and muscle) for systemic error correction in CBCT that depends on the relative object position in the image volume. Phantom calibration was performed to calculate the acquired attenuation ratio in Hounsfield units (HU), comparable to the results from clinical multislice spiral computed tomography (MSCT). In addition, a small animal study with an osteoporotic rat model was evaluated to show the feasibility of this presented method to quantitatively assess bone density using a CBCT system.
RESULTS: The phantom study results showed that the calibration process successfully corrected the systemic inaccuracy from CBCT, and the calibrated HU values agreed with the values measured from MSCT. In the small animal study, the quantitative bone densities assessed from the calibrated CBCT results were consistent with the results from MSCT data.
CONCLUSION: A practical method to quantitatively estimate attenuation (HU) values for bone tissues from CBCT scans that are comparable to MSCT scans is proposed. The method may improve the quantification ability of CBCT scanning without any additional hardware requirements.

Entities:  

Mesh:

Year:  2012        PMID: 23225074     DOI: 10.1007/s11548-012-0803-5

Source DB:  PubMed          Journal:  Int J Comput Assist Radiol Surg        ISSN: 1861-6410            Impact factor:   2.924


  22 in total

1.  A comparison of a new limited cone beam computed tomography machine for dental use with a multidetector row helical CT machine.

Authors:  Koji Hashimoto; Yoshinori Arai; Kazuo Iwai; Masao Araki; Shoji Kawashima; Masaaki Terakado
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2003-03

Review 2.  High resolution X-ray computed tomography: an emerging tool for small animal cancer research.

Authors:  M J Paulus; S S Gleason; S J Kennel; P R Hunsicker; D K Johnson
Journal:  Neoplasia       Date:  2000 Jan-Apr       Impact factor: 5.715

3.  Deriving Hounsfield units using grey levels in cone beam computed tomography.

Authors:  P Mah; T E Reeves; W D McDavid
Journal:  Dentomaxillofac Radiol       Date:  2010-09       Impact factor: 2.419

4.  Cilengitide inhibits progression of experimental breast cancer bone metastases as imaged noninvasively using VCT, MRI and DCE-MRI in a longitudinal in vivo study.

Authors:  Tobias Bäuerle; Dorde Komljenovic; Maximilian Merz; Martin R Berger; Simon L Goodman; Wolfhard Semmler
Journal:  Int J Cancer       Date:  2011-05-15       Impact factor: 7.396

5.  Potential applications of flat-panel volumetric CT in morphologic and functional small animal imaging.

Authors:  Susanne Greschus; Fabian Kiessling; Matthias P Lichy; Jens Moll; Margareta M Mueller; Rajkumar Savai; Frank Rose; Clemens Ruppert; Andreas Günther; Marcus Luecke; Norbert E Fusenig; Wolfhard Semmler; Horst Traupe
Journal:  Neoplasia       Date:  2005-08       Impact factor: 5.715

6.  Effects of image artifacts on gray-value density in limited-volume cone-beam computerized tomography.

Authors:  Akitoshi Katsumata; Akiko Hirukawa; Shinji Okumura; Munetaka Naitoh; Masami Fujishita; Eiichiro Ariji; Robert P Langlais
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  2007-04-20

7.  A new volumetric CT machine for dental imaging based on the cone-beam technique: preliminary results.

Authors:  P Mozzo; C Procacci; A Tacconi; P T Martini; I A Andreis
Journal:  Eur Radiol       Date:  1998       Impact factor: 5.315

8.  Correlation between pixel values in a cone-beam computed tomographic scanner and the computed tomographic values in a multidetector row computed tomographic scanner.

Authors:  Jira Chindasombatjaroen; Naoya Kakimoto; Hiroaki Shimamoto; Shumei Murakami; Souhei Furukawa
Journal:  J Comput Assist Tomogr       Date:  2011 Sep-Oct       Impact factor: 1.826

9.  Cone-beam CT for radiotherapy applications.

Authors:  P S Cho; R H Johnson; T W Griffin
Journal:  Phys Med Biol       Date:  1995-11       Impact factor: 3.609

10.  Induction of osteoporosis with its influence on osteoporotic determinants and their interrelationships in rats by DEXA.

Authors:  Christian Heiss; Parameswari Govindarajan; Gudrun Schlewitz; Nasr Y A Hemdan; Nathalie Schliefke; Volker Alt; Ulrich Thormann; Katrin Susanne Lips; Sabine Wenisch; Alexander C Langheinrich; Daniel Zahner; Reinhard Schnettler
Journal:  Med Sci Monit       Date:  2012-06
View more
  8 in total

1.  Automated implant segmentation in cone-beam CT using edge detection and particle counting.

Authors:  Ruben Pauwels; Reinhilde Jacobs; Hilde Bosmans; Pisha Pittayapat; Pasupen Kosalagood; Onanong Silkosessak; Soontra Panmekiate
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-07       Impact factor: 2.924

Review 2.  CBCT-based bone quality assessment: are Hounsfield units applicable?

Authors:  R Pauwels; R Jacobs; S R Singer; M Mupparapu
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

Review 3.  Bone mineral density in cone beam computed tomography: Only a few shades of gray.

Authors:  Marcio José da Silva Campos; Thainara Salgueiro de Souza; Sergio Luiz Mota Júnior; Marcelo Reis Fraga; Robert Willer Farinazzo Vitral
Journal:  World J Radiol       Date:  2014-08-28

4.  Bone mineral density, bone microstructure, and bone turnover markers in females with temporomandibular joint osteoarthritis.

Authors:  Seok Woo Hong; Jeong-Hyun Kang
Journal:  Clin Oral Investig       Date:  2021-04-16       Impact factor: 3.573

5.  Association of Condylar Bone Quality with TMJ Osteoarthritis.

Authors:  J Shi; S Lee; H C Pan; A Mohammad; A Lin; W Guo; E Chen; A Ahn; J Li; K Ting; J H Kwak
Journal:  J Dent Res       Date:  2017-05-05       Impact factor: 8.924

6.  Predictability of bone density at posterior mandibular implant sites using cone-beam computed tomography intensity values.

Authors:  Mustafa Alkhader; Malik Hudieb; Yousef Khader
Journal:  Eur J Dent       Date:  2017 Jul-Sep

7.  Diagnostic Performance of Conebeam CT Pixel Values in Active Fenestral Otosclerosis.

Authors:  F Deng; P Touska; K L Reinshagen; H D Curtin; A F Juliano
Journal:  AJNR Am J Neuroradiol       Date:  2021-06-17       Impact factor: 4.966

8.  Pedicle Screws Challenged: Lumbar Cortical Density and Thickness Are Greater in the Posterior Elements Than in the Pedicles.

Authors:  Khalid Odeh; Alexander Rosinski; Jeremi Leasure; Dimitriy Kondrashov
Journal:  Global Spine J       Date:  2019-11-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.