OBJECTIVE: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light-emitting diode (LED) or quartz tungsten halogen (QTH) light source. MATERIAL AND METHODS: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. RESULTS: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. CONCLUSION: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.
OBJECTIVE: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light-emitting diode (LED) or quartz tungsten halogen (QTH) light source. MATERIAL AND METHODS: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. RESULTS: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. CONCLUSION: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.
Due to their excellent esthetic and superior mechanical properties, resin cements are
considered the material of choice to be used with metal-free restorations[10]. The mechanical properties and
biocompatibility of resin cements are directly related to the degree of monomer
conversion[16]. Several studies
have demonstrated that the degree of monomer conversion determines the surface hardness
and wear resistance of the resin materials[16,20]. Maximum monomer
conversion is always desired to ensure optimum properties and biocompatibility and to
reduce water solubility[7,37]. However, total monomer conversion with
resin polymers is virtually unattainable and these materials always display some
residual monomer after polymerization.Dual cured resin cements have been advocated for luting ceramic restorations because
they do not adversely affect esthetics and they allow adequate working time to complete
the procedure. However, the amount or degree of conversion of the resin cement may vary,
especially with bulky restorations thereby compromising the retention of the crown or
inlay restoration[9,11,12,15,20,31]. If a photo-cured or
dual cured resin material does not receive a sufficient number of photons at the correct
wavelength, the amount of polymerization and degree of conversion will be
inadequate[25]. Furthermore, other
studies have reported an inverse relationship between the thickness of ceramic inlays
and the surface hardness of light-cured and dual cured resin cements[12,15].The polymerization process of composite materials can be accomplished with different
light sources. Quartz tungsten halogen (QTH) curing units are currently the most
commonly used means of curing dental composites. However, this technology has several
drawbacks, such as a limited lifespan (40-100 h) and the generation of high temperatures
during light emission. This results in a degradation of the bulb, reflector and filter
over time and reduction of the QTH curing effectiveness[36]. To overcome these problems, new light-sources have been
developed and introduced to the market, such as, plasma arc (PAC), laser lights and
light-emitting diode (LED)[26,37].Although the first generation of LED curing lights resulted in insufficient
polymerization of composite resins[8,24,33], newer versions of LED units deliver a spectral emission with
greater peak irradiance and power output. Some studies have shown that LED is now as
effective as QTH curing light units[4,17,28,30]. LED units have an
expected lifetime of several thousand h without significant degradation of light flux
over time and no filters are required, since their spectral output falls conveniently
within the absorption spectrum of the camphoroquinone photoinitiator (400-500
nm)[18,31,34].The aim of this investigation was to evaluate the surface hardness of a dual-cure resin
cement (RelyX ARC) cured using QTH and LED curing light sources through indirect resin
disks of different thicknesses. The null hypotheses tested were: 1- There is no
difference in the surface hardness of the resin cement cured through indirect resin
disks of different thickness; 2- There is no difference in the surface hardness of resin
cement cured with a LED light source compared to a QTH light source.
MATERIAL AND METHODS
Disks measuring 5 mm in diameter and thicknesses of 1, 2 and 3 mm were fabricated with
an indirect composite resin (Cristobal; Microdont São Paulo, SP, Brazil)
according to the manufacturer’s instructions. Then, eighteen 2mm-thick specimens were
prepared from a dualcure resin cement (RelyX ARC; 3M/ESPE, St. Paul, MN, USA) according
to the manufacturers’ instructions for ratio and mixing. For each specimen, a ring
placed on a glass slide lined with a mylar polyester strip was filled with the resin
cement and covered with another mylar strip. Then, an indirect composite resin disk (1,
2 and 3 mm thick) was placed onto this set, and the resin cement was photoactivated
through the resin disk for 40 s with one of the two curing light sources: LED
(EliparTM FreeLight 2 LED Curing Light; 3M/ESPE; 800 mW/cm2) or
QTH (Optilight Plus; Gnatus, Ribeirão Preto, SP, Brazil; 500 mW/cm2).
Three specimens were prepared for each test condition, forming 6 groups: 1- QTH +
1-mm-thick indirect resin disk; 2- LED + 1mm-thick indirect resin disk; 3- QTH +
2-mmthick indirect resin disk; 4- LED + 2-mm-thick indirect resin disk; 5- QTH +
3-mm-thick indirect resin disk; 6- LED + 3-mm-thick indirect resin disk. All specimens
were stored dry in boxes in a darkened incubator at 37°C for 24 h before testing.A hardness test using a Vickers diamond indenter (Digital Hardness Tester FM,
Future-Tech, Tokyo, Japan) was performed on the surface of each specimen with a 50-g
load for 15 s. Three indentations were obtained for each of the upper and the lower
surfaces of each resin cement specimen. Mean Vickers hardness numbers (VHN) were then
calculated for both surfaces. The data were analyzed by two-way ANOVA. If a
statistically significant difference was observed among the groups, a Tukey- Kramer test
was used to determine pair-wise differences. A pvalue of 0.05 or less was considered
statistically significant, and a difference in mean VHN hardness values of 20% or
greater was considered to be clinically meaningful.
RESULTS
Mean Vickers hardness values (VHN) and standard deviations for the top surface of the
resin cement specimens are presented in Table 1.
For both types of curing light sources, the mean VHN values for the top surface of the
resin cement specimens decreased as the indirect resin disk thickness increased. The VHN
of the top surface of the resin cement was 22.5% lower when a 3mm-thick indirect resin
disk was used compared to when a 1-mm-thick indirect resin disk was used for the LED
unit, and 49.7% lower for the QTH light source. The QTH light source produced a slightly
greater VHN value (12.1%) compared to the LED light source using the 1-mm-thick indirect
resin disk, but lower VHN values with the 2- and 3-mm-thick indirect resin disks (36.3%
and -47.0%, respectively). The differences in surface hardness values for the 2and
3-mm-thick indirect resin disk were clinically meaningful in favor of the LED curing
light source. There was no interaction between the type of curing light source and the
indirect resin disk thickness for the top surface of the resin cement specimens. No
statistically significant difference was found in the mean VHN values for the top
surface of the resin cement (p= 0.24) between the two types of curing light sources.
There was, however, a statistically significant difference in mean hardness among the
indirect resin disk thicknesses (p=0.01). A Tukey-Kramer test revealed that this
difference was statistically significant (p< 0.05) between the 1- and 3-mmthick
indirect resin disks, but not between the 1and 2-mm-thick disks or between the 2- and
3mm-thick disks.
Table 1
Mean hardness values (VHN) (standard deviation) for the top surface of the
resin cement specimens varying the curing light source and thickness of the
indirect resin disks
Resin disk thickness (mm)
Light Source
Top *
% Difference Compared to 1 mm
% Difference ** by curing light source and thickness
1.0
QTH
46.1 (9.89)ª
-
12.1%
1.0
LED
41.7 (1.95)ab
-
2.0
QTH
27.0 (11.98)ab
-41.4%
36.3%
2.0
LED
36.8 (2.80)ab
-11.8%
3.0
QTH
23.2 (11.27)b
-49.7%
47.0%
3.0
LED
32.3 (2.31 )ab
-22.5%
Same superscripted letters indicate no statistically significant differences (p
> 0.05).
Absolute difference in mean VHN/ mean QTH VHN.
Same superscripted letters indicate no statistically significant differences (p
> 0.05).Absolute difference in mean VHN/ mean QTH VHN.Mean VHN means and standard deviations for the bottom surface of the resin cement
specimens are presented in Table 2. The LED
light source produced slightly greater VHN values compared to the QTH light source when
used with all three indirect resin disk thicknesses. The VHN values on the bottom
surface decreased dramatically with the increase of the indirect resin disk thickness
for both types of curing light sources. The mean VHN value on the bottom surface of the
resin cement was 76.6% lower when a 3mm-thick indirect resin disk was used compared to a
1-mm-thick indirect resin disk was used for the LED light source and 69.6% lower for the
QTH light source. There was statistically significant difference between the mean VHN
values for the type of curing light source (p= 0.03) and, similarly, for the indirect
resin disk thicknesses (p< 0.001). However, there was also a statistically
significant interaction (p= 0.009) when the type of curing light source and the indirect
resin disk thickness were combined. The LED light source using a 1-mm-thick indirect
resin disk produced the highest mean VHN value on the bottom surface, and the QTH light
source using a 3-mm-thick indirect resin disk produced the lowest VHN value. The
Tukey-Kramer test revealed that the difference in the mean VHN values for these two
specific combinations was statistically significant (p< 0.05). The bottomto-top
surface hardness ratios are shown in Table
3.
Table 2
Mean hardness values (VHN) (standard deviation) for the bottom surface of the
resin cement specimens varying the curing light source and thickness of the
indirect resin disks
Resin diskt hickness (mm)
Light Source
Bottom*
% Difference Compared to 1 mm
% Difference** by curing light source and thickness
1.0
QTH
19.1 (4.54)b
-
67.5%
1.0
LED
32.0 (3.28)ª
-
2.0
QTH
11.4 (4.67)b
-40.3%
0.87%
2.0
LED
11.5 (1.84)b
-64.1%
3.0
QTH
5.8 (1.60)b
-69.6%
29.3%
3.0
LED
7.5 (0.88)b
-76.6%
The same superscripted letters indicate no significant differences (p >
0.05).
Absolute difference in mean VHN/ mean QTH VHN.
Table 3
Bottom-to-top surface microhardness ratio (%)
Resin disk thickness (mm)
QTH
LED
1.0
42.13
76.07
2.0
45.25
32.39
3.0
38.01
23.45
The same superscripted letters indicate no significant differences (p >
0.05).Absolute difference in mean VHN/ mean QTH VHN.Generally, higher mean VHN values were obtained when the resin cement specimens were
photoactivated with the LED curing light source. The mean VHS value decreased with the
increase of the indirect resin disk thickness. The top surfaces of the resin cement
specimens had consistently higher VHS values than the bottom surfaces.
DISCUSSION
The surface hardness of cured resin materials can be a useful indicator of the degree of
monomer conversion[2,21,30,32]. Uhl, et al.[34] (2003) showed that the degree of polymerization of
composite materials can be better evaluated with Knoop or Vickers hardness than with
depth of cure tests using a penetrometer. Hardness tests may be classified based on the
magnitude of indentation loads such as macrohardness, microhardness and nanohardness,
being microhardness tests (Knoop, Vickers) the most common test used for composite
materials[1].Adequate polymerization of resin cements materials may be a problem under indirect
restorations[12]. According to
Hasegawa, et al.[15] (1991), the final
hardness of the dual cured cements depends on the amount of exposure to the curing
light. None of the dual cured resin cements tested in their study achieved complete
hardening when not exposed to light, resulting in lower hardness as the chemically cured
component did not provide complete hardening. This confirms the importance of light
exposure to increase the hardness of dual cured cements.The results of this study reject the first null hypothesis. Increased indirect resin
disk thickness resulted in lower VHN values on both top and bottom surfaces of the resin
cement specimens. These findings are similar to those of previous studies[9,12,19,23]. The maximum indirect resin disk thickness tested in this study was
3 mm, simulating the mean thickness of indirect restorations (2.5 mm). However, other
studies have shown light obstruction beyond 4 mm thickness of indirect resin
disks[12,23].Another important consideration related to the degree of resin polymerization is the
light intensity delivered by the curing unit. Resin-based materials may present
incomplete polymerization rate when light curing units with low outputs are
used[8]. The ISO-recommended
intensity for polymerization lights is 300 mW/cm2
[16]. Light intensity of LED light
curing units is fundamental for their good functioning[3]. In this study, light intensities of 500 and 800
mW/cm2 were delivered by the QTH and LED units, respectively.The second null hypothesis of this study was also rejected. Higher VHN values were
produced with the LED curing light source compared to the QTH curing light source,
except for the one mm thick indirect resin disk. The sample size used in this study was
insufficient to determine that the difference between the hardness values for the two
light curing sources on the top surface of the resin cement with a one mm indirect resin
disk was statistically significant. Cefaly, et al.[6] (2009) evaluated the microhardness of RMGICs using LED and QTH
units, and observed that when a LED light was used the microhardness values varied
depending on the restorative material tested, in the same way as observed by Cefaly, et
al.[5] (2005) for resin-based
materials. Franco, et al.[13] (2007),
Price, et al.[29] (2003) and Dunn and
Bush[8] (2002) considered that QTH
was superior to LED units for curing composites. For Kurachi, et al.[22] (2001), the first generation of LEDs (6
diodes - 79 mW/cm2) reached 60% of the hardness achieved with QTH units (475
mW/ cm2), and reported that specimens cured with LED needed more exposure
time to obtain the same depth of cure obtained with halogen light. This study used a
high-power energy LED source. The first generation of LEDs presented approximately half
of the power of the new generation[26].
Some authors[2,35] have reported that high-power LED units present the same
efficiency of QTH units, with the advantage of preventing overheating.Uhl, et al.[35] (2004), Uhl, et
al.[36] (2005) reported similar
hardness values from composite material photoactivated with QTH and with
second-generation LEDs (901 mW/cm2). These findings agree with those of Piva,
et al.[28] (2008), who used QTH (589
mW/cm2) and LED (614 mW/ cm2) units, and Gomes, et
al.[14] (2006). In the present
study the LED curing light source generally produced higher surface hardness values,
probably due to the higher energy density used in this group (LED - 24 J/cm2
versus QTH 15 J/cm2) and light intensity (QTH - 800 mW/ cm2 versus
500 mW/cm2) [3].There is no internationally recognized standard for adequate depth of cure as measured
by the relative hardness method[17]. For
proper depth of cure, a relative hardness value (100 x hardness of lower
surface/hardness of top surface) must be higher than 80%[27]. In this study, the bottomto-top surface hardness ratios
were below 80% in all groups. This result is not in accordance with the study of
Hooshmand, et al.[17] (2009), who used
1-mm-thick specimens.
CONCLUSIONS
Within the limitations of an in vitro investigation, the following
conclusions can be reached: 1. For both the top and bottom surfaces of the resin cement
specimens, the mean VHN values decreased as the thickness of the indirect resin disk
thickness increased from 1 to 3 mm, irrespectively of the curing light source used; 2.
Higher mean VHN values were found on the top surface compared to the bottom surface of
the resin cement specimens regardless of the thickness of the indirect resin disk or the
type of curing light source; 3. Except for the 1-mm-thick indirect resin disk, higher
VHN values were produced with the LED unit compared to the QTH unit; 4. On the top
surface of the resin cement specimens, the LED curing source produced significantly
higher mean VHN values than the QTH light source when the cement specimens were
photoactivated through 2- and 3-mm-thick indirect resin disks; 5. On the bottom surface
of the resin cement specimens, there was a statistically significant interaction between
the type of curing light source and the thickness of the indirect resin disks, that is
LED curing source produced significantly higher mean VHN values than the QTH light
source when the cement specimens were photoactivated through indirect resin disks
thicker than 1 mm.
Authors: Laura Ceballos; María Victoria Fuentes; Héctor Tafalla; Alvaro Martínez; Josefa Flores; Jesús Rodríguez Journal: Med Oral Patol Oral Cir Bucal Date: 2009-01-01
Authors: Daniela Francisca Gigo Cefaly; Giovano Augusto de Oliveira Ferrarezi; Celiane Mary Carneiro Tapety; José Roberto Pereira Lauris; Maria Fidela de Lima Navarro Journal: Braz Dent J Date: 2005