Literature DB >> 19114957

Curing effectiveness of resin composites at different exposure times using LED and halogen units.

Laura Ceballos1, María Victoria Fuentes, Héctor Tafalla, Alvaro Martínez, Josefa Flores, Jesús Rodríguez.   

Abstract

OBJECTIVE: To compare the polymerization effectiveness of two resin composites cured with a quartz tungsten halogen (QTH) lamp or a light emitting diodes (LED) unit. STUDY
DESIGN: Filtek Z250 (3M ESPE) and Spectrum TPH (Dentsply DeTrey) resin composites were placed in 9 mm deep and 4 mm wide metallic molds and cured using the QTH light Hilux 200 (Benlioglu) or the LED unit Smartlite IQ (Dentsply DeTrey) for 20 or 40 s (three specimens per group). Measurement of depth of cure was carried out by means of a scraping technique, according to ISO 4049. The microhardness measurements were performed using a calibrated Vickers indenter (100 g load, 30 s) at depths of 0.5, 1.5, 2.5, 3.5, 4.5 and 5.5 mm from the top of the composite in the same specimens. Results were analyzed by ANOVA, Student's t and Student-Newman-Keuls tests (p<0.05).
RESULTS: Filtek Z250 exhibited higher depth of cure and Vickers microhardness values than Spectrum TPH under each experimental condition evaluated. Depth of cure and microhardness were not affected by the curing light used. However, hardness values were influenced by the interaction between curing light and exposure time. Specimens irradiated for 20 s exhibited higher microhardness values when the LED curing light was used. Exposure time had no influence on the microhardness values for depths from 0.5 to 2.5 mm. At higher depths, irradiation for 40 s produced greater microhardness values.
CONCLUSIONS: Curing effectiveness of resin composite is not only dependent on the curing light unit. Results vary greatly with composite brand, thickness of the resin composite and the duration of the exposure.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19114957

Source DB:  PubMed          Journal:  Med Oral Patol Oral Cir Bucal        ISSN: 1698-4447


  14 in total

1.  Light diffusion through composite restorations added with spherical glass mega fillers.

Authors:  M Andreasi Bassi; S Andreasi Bassi; C Andrisani; S Lico; L Baggi; D Lauritano
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

2.  The effect of irradiation distance on microhardness of resin composites cured with different light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  Eur J Dent       Date:  2010-10

3.  Terahertz time-domain spectroscopy for monitoring the curing of dental composites.

Authors:  Michael Schwerdtfeger; Sina Lippert; Martin Koch; Andreas Berg; Stefan Katletz; Karin Wiesauer
Journal:  Biomed Opt Express       Date:  2012-10-16       Impact factor: 3.732

4.  Comparison of light transmittance in different thicknesses of zirconia under various light curing units.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

5.  Comparative evaluation of surface hardness and depth of cure of silorane and methacrylate-based posterior composite resins: An in vitro study.

Authors:  Abhishek Agrawal; Narendra U Manwar; Shubha G Hegde; Manoj Chandak; Anuja Ikhar; Aditya Patel
Journal:  J Conserv Dent       Date:  2015 Mar-Apr

6.  Hardness Evaluation of Composite Resins Cured with QTH and LED.

Authors:  Behnaz Esmaeili; Hengameh Safarcherati; Assila Vaezi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-03-05

7.  Knowledge and Attitude of Dental Clinicians towards Light-Curing Units: A Cross-Sectional Study.

Authors:  Dana Al-Senan; Fatin Ageel; Amani Aldosari; Haifa Maktabi
Journal:  Int J Dent       Date:  2021-06-14

8.  Comparative depth of cure among two light-cured core build-up composites by surface vickers hardness.

Authors:  Mr Rouhollahi; M Mohammadibasir; Sh Talim
Journal:  J Dent (Tehran)       Date:  2012-09-30

9.  Light transmittance of zirconia as a function of thickness and microhardness of resin cements under different thicknesses of zirconia.

Authors:  Isil Cekic-Nagas; Ferhan Egilmez; Gulfem Ergun; Bekir-Murat Kaya
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01

10.  Does an additional UV LED improve the degree of conversion and Knoop Hardness of light-shade composite resins?

Authors:  Maria Cecília Caldas Giorgi; Flávio Henrique Baggio Aguiar; Luís Eduardo Silva Soares; Airton Abrahão Martin; Priscila Christiane Suzy Liporoni; Luís Alexandre Maffei Sartini Paulillo
Journal:  Eur J Dent       Date:  2012-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.