Knoop hardness depth profiles and compressive strength of selected dental composites polymerized with halogen and LED light curing technologies.

Alexander Uhl1, Robin W Mills, Richard W Vowles, Klaus D Jandt.   

Abstract

After the first light-emitting diode (LED) light curing units (LCUs) became available commercially, a comparison of mechanical properties between materials polymerized with conventional halogen lamps and this new technology was required. This study, therefore, investigated the curing performance of two conventional commercial halogen LCUs (Translux CL, Spectrum800), a custom-made LED LCU prototype, and one of the first commercially available LED LCUs (LUXoMAX). The Spectrum800 was adjusted to a similar irradiance to the custom-made LED LCU prototype. Both technologies were compared by measuring compressive strength and Knoop hardness depth profiles for selected dental composites polymerized for 20 or 40 s. Four dental composites (Z100, Spectrum TPH, Solitaire2, and Definite) were used. Two of these composites (Solitaire2 and Definite) contain co-initiators in addition to the standard photoinitiator camphorquinone. In general, the material hardness obtained with the LUXoMAX was statistically significantly (p < 0.05) lower at the depths of 0.1, 1.0, 1.9, and 3.1 mm, for all composites and curing times, than for the other three LCUs. The LED LCU prototype achieved, with one exception, up to a depth of 1.9 mm a material hardness for the composites Z100, Spectrum TPH and Solitaire2 that was not statistically significant different (p < 0.05) from the hardness obtained with the halogen LCUs. At a greater depth (3.1 mm), however, the LED LCU prototype showed statistically significantly lower hardness values than the halogen units. The compressive strength test showed at a 95% confidence level that similar compressive strengths were achieved with the LCUs LUXoMAX and Spectrum800, and the Translux and LED LCU prototype. Copyright 2002 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12418017     DOI: 10.1002/jbm.10390

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  11 in total

1.  Marginal and internal adaptation of Class II ormocer and hybrid resin composite restorations before and after load cycling.

Authors:  N Kournetas; M Chakmakchi; A Kakaboura; C Rahiotis; J Geis-Gerstorfer
Journal:  Clin Oral Investig       Date:  2004-07-10       Impact factor: 3.573

2.  Physical properties of self-, dual-, and light-cured direct core materials.

Authors:  Stefan Rüttermann; Ian Alberts; Wolfgang H M Raab; Ralf R Janda
Journal:  Clin Oral Investig       Date:  2010-04-07       Impact factor: 3.573

3.  Tris(trimethylsilyl)silane as a co-initiator for dental adhesive: Photo-polymerization kinetics and dynamic mechanical property.

Authors:  Linyong Song; Qiang Ye; Xueping Ge; Anil Misra; Paulette Spencer
Journal:  Dent Mater       Date:  2015-11-27       Impact factor: 5.304

4.  Effect of Energy Density on the Physical Properties of Resin-Based Restorative Materials when Polymerized with Quartz-Tungsten Halogen or LED-Light.

Authors:  Stefan Ruttermann; Senay Tomruk; Wolfgang H M Raab; Ralf Janda
Journal:  Eur J Dent       Date:  2010-04

5.  The effects of light curing units and environmental temperatures on C = C conversion of commercial and experimental bonding agents.

Authors:  Tahereh Sadat Jafarzadeh-Kashi; Mohmmad Erfan; Salmeh Kalbasi; Malihe Ghadiri; Vahid Rakhshan
Journal:  Saudi Dent J       Date:  2014-08-06

6.  Influence of light curing units on failure of directcomposite restorations.

Authors:  Sameer Jadhav; Vivek Hegde; Gayatri Aher; Naylah Fajandar
Journal:  J Conserv Dent       Date:  2011-07

7.  Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources.

Authors:  Sayed Mostafa Mousavinasab; Ian Meyers
Journal:  Eur J Dent       Date:  2011-07

8.  Effect of reduced exposure times on the cytotoxicity of resin luting cements cured by high-power led.

Authors:  Gulfem Ergun; Ferhan Egilmez; Sukran Yilmaz
Journal:  J Appl Oral Sci       Date:  2011 May-Jun       Impact factor: 2.698

9.  Hardening of a dual-cure resin cement using QTH and LED curing units.

Authors:  Maria Jacinta Moraes Coelho Santos; Sheila Pestana Passos; Monalisa Olga Lessa da Encarnação; Gildo Coelho Santos; Marco Antonio Bottino
Journal:  J Appl Oral Sci       Date:  2010 Mar-Apr       Impact factor: 2.698

10.  Use of Artificial Neural Network in Determination of Shade, Light Curing Unit, and Composite Parameters' Effect on Bottom/Top Vickers Hardness Ratio of Composites.

Authors:  Hacer Deniz Arısu; Evrim Eligüzeloglu Dalkilic; Fehime Alkan; Sebnem Erol; Mine Betul Uctasli; Alican Cebi
Journal:  Biomed Res Int       Date:  2018-11-12       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.