Literature DB >> 18051007

Evaluation of curing light distance on resin composite microhardness and polymerization.

Kátia Martins Rode1, Yoshio Kawano, Miriam Lacalle Turbino.   

Abstract

This study evaluated the influence of the curing tip distance on cure depth of a resin composite by measuring Vickers microhardness and determining the degree of conversion by using FT-Raman spectroscopy. The light curing units used were halogen (500mW/cm2) and LED (900mW/cm2) at a conventional intensity and an Argon laser at 250mW. The exposure time was 40 seconds for the halogen light, 20 seconds for the LED and 20 and 30 seconds for the Argon laser. The curing tip distances of 0, 3, 6 and 9 mm were used and controlled via the use of metal rings. The composite was placed in a black matrix in one increment at a thickness of 1 mm to 4 mm. The values of microhardness and the degree of conversion were analyzed separately by ANOVA (Analysis of Variance) and Tukey test, with a significance level set at 5%. Correlations were analyzed using the Pearson test. The results obtained conclude that greater tip distances produced a decrease in microhardness and degree of conversion values, while increasing the resin thickness decreased the microhardness and degree of conversion values. A higher correlation between microhardness and the degree of conversion was shown. This study suggests that the current light curing units promote a similar degree of conversion and microhardness, provided that the resin is not thicker than 1 mm and the light source is at a maximum distance of 3 mm from the resin surface.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18051007     DOI: 10.2341/06-163

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  19 in total

1.  Argon ion laser curing depth effect on a composite resin.

Authors:  Míriam Lacalle Turbino; Luis Carlos Belan; Valéria Soprano; Kátia Martis Rode; Patrícia Ramos Lloret; Michel Nicolau Youssef
Journal:  Lasers Med Sci       Date:  2010-05-28       Impact factor: 3.161

2.  Effect of two lasers on the polymerization of composite resins: single vs combination.

Authors:  Jung-Hoon Ro; Sung-Ae Son; Jeong-kil Park; Gye-Rok Jeon; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2015-04-17       Impact factor: 3.161

3.  Influence of light-activation protocol on methacrylate resin-composite evaluated by dynamic mechanical analysis and degree of conversion.

Authors:  Maria Cecília C Giorgi; Vinícius Pistor; Raquel S Mauler; Débora A N L Lima; Giselle M Marchi; Flávio H B Aguiar
Journal:  Lasers Med Sci       Date:  2014-04-17       Impact factor: 3.161

4.  Micro-hardness evaluation of a micro-hybrid composite resin light cured with halogen light, light-emitting diode and argon ion laser.

Authors:  Katia M Rode; Patricia M de Freitas; Patricia R Lloret; Lynn G Powell; Miriam L Turbino
Journal:  Lasers Med Sci       Date:  2007-12-05       Impact factor: 3.161

5.  Evaluation of Vickers hardness and depth of cure of six composite resins photo-activated with different polymerization modes.

Authors:  C Poggio; M Lombardini; S Gaviati; M Chiesa
Journal:  J Conserv Dent       Date:  2012-07

6.  Five second photoactivation? A microhardness and marginal adaptation in vitro study in composite resin restorations.

Authors:  Carlos Alberto Kenji Shimokawa; Paula Mendes Acatauassú Carneiro; Tamile Rocha da Silva Lobo; Victor Elias Arana-Chavez; Michel Nicolau Youssef; Míriam Lacalle Turbino
Journal:  Int Dent J       Date:  2016-04-08       Impact factor: 2.607

7.  Flexural strength of a composite resin light cured with different exposure modes and immersed in ethanol or distilled water media.

Authors:  Saulo Galvão Dos Santos; Marcos Ribeiro Moysés; Carlos Eduardo Pinto Alcântara; José Carlos Rabelo Ribeiro; João Gustavo Rabelo Ribeiro
Journal:  J Conserv Dent       Date:  2012-10

8.  Influence of polymerization time and depth of cure of resin composites determined by Vickers hardness.

Authors:  Marco Lombardini; Marco Chiesa; Andrea Scribante; Marco Colombo; Claudio Poggio
Journal:  Dent Res J (Isfahan)       Date:  2012-11

9.  Effect of food stimulated liquids and thermocycling on the monomer elution from a nanofilled composite.

Authors:  Masumeh Hasani Tabatabaei; Sima Sadrai; Seyed Hossein Bassir; Nadia Veisy; Somaye Dehghan
Journal:  Open Dent J       Date:  2013-07-26

10.  Evaluation of degree of conversion and hardness of dental composites photo-activated with different light guide tips.

Authors:  Marília Regalado Galvão; Sergei Godeiro Fernandes Rabelo Caldas; Vanderlei Salvador Bagnato; Alessandra Nara de Souza Rastelli; Marcelo Ferrarezi de Andrade
Journal:  Eur J Dent       Date:  2013-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.