Literature DB >> 20465901

Use of the New Solitaire (TM) AB Device for Mechanical Thrombectomy when Merci Clot Retriever Has Failed to Remove the Clot. A Case Report.

C Castaño1, J Serena, A Dávalos.   

Abstract

SUMMARY: The Merci Retrieval System (TM) (Concentric Medical, Mountain View, CA, USA) was approved in 2004 for restoring blood flow in patients experiencing an acute stroke who are otherwise ineligible for intravenous tPA, or in whom intravenous tPA treatment has failed. However, this treatment results in successful recanalization in less than 60% of treatable vessels (Multi MERCI trial). We describe the use of a novel device, the Solitaire(TM) AB Neurovascular Remodeling Device (ev3 Inc., Irvine, CA, USA) that received the CE Mark for the treatment of neurovascular disease in 2007 and can recanalize arteries when MERCI has failed. We describe a case of mechanical thrombectomy in which a new device, Solitaire(TM) AB, was used for acute cerebral ischemia in the setting of middle cerebral artery occlusion after unsuccessful recanalization with the MERCI(R) Retriever. Excellent angiographic and good clinical results were obtained without any complication. The Solitaire(TM) AB device was able to retrieve and remove clots efficiently from the middle cerebral artery when the MERCI system failed, thereby offering a new alternative in the treatment of acute ischemic stroke.

Entities:  

Year:  2009        PMID: 20465901      PMCID: PMC3299024          DOI: 10.1177/159101990901500212

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  12 in total

1.  A novel microcatheter-delivered, highly-flexible and fully-retrievable stent, specifically designed for intracranial use. Technical note.

Authors:  H Henkes; A Flesser; S Brew; E Miloslavski; A Doerfler; S Felber; H Monstadt; D Kuehne
Journal:  Interv Neuroradiol       Date:  2004-10-22       Impact factor: 1.610

2.  Intra-arterial prourokinase for acute ischemic stroke. The PROACT II study: a randomized controlled trial. Prolyse in Acute Cerebral Thromboembolism.

Authors:  A Furlan; R Higashida; L Wechsler; M Gent; H Rowley; C Kase; M Pessin; A Ahuja; F Callahan; W M Clark; F Silver; F Rivera
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

3.  Recombinant tissue plasminogen activator in acute thrombotic and embolic stroke.

Authors:  G J del Zoppo; K Poeck; M S Pessin; S M Wolpert; A J Furlan; A Ferbert; M J Alberts; J A Zivin; L Wechsler; O Busse
Journal:  Ann Neurol       Date:  1992-07       Impact factor: 10.422

4.  Technical Note on VDS. A System for the Endovascular Electrolytical Detachment of Platinum Coils at Variable Length.

Authors:  H Henkes; P Drepper; J Speder; S Felber; H Monstadt; D Kühne
Journal:  Interv Neuroradiol       Date:  2004-10-20       Impact factor: 1.610

5.  Safety of mechanical thrombectomy and intravenous tissue plasminogen activator in acute ischemic stroke. Results of the multi Mechanical Embolus Removal in Cerebral Ischemia (MERCI) trial, part I.

Authors:  W S Smith
Journal:  AJNR Am J Neuroradiol       Date:  2006 Jun-Jul       Impact factor: 3.825

6.  MERCI 1: a phase 1 study of Mechanical Embolus Removal in Cerebral Ischemia.

Authors:  Y Pierre Gobin; Sidney Starkman; Gary R Duckwiler; Thomas Grobelny; Chelsea S Kidwell; Reza Jahan; John Pile-Spellman; Alan Segal; Fernando Vinuela; Jeffrey L Saver
Journal:  Stroke       Date:  2004-10-28       Impact factor: 7.914

7.  Tissue plasminogen activator for acute ischemic stroke.

Authors: 
Journal:  N Engl J Med       Date:  1995-12-14       Impact factor: 91.245

8.  Revascularization of symptomatic subacute cerebrovascular occlusions with a self-expanding intracranial stent system.

Authors:  Michael E Kelly; Raymond D Turner; Shaye I Moskowitz; Vivek R Gonugunta; Peter A Rasmussen; Thomas J Masaryk; David Fiorella
Journal:  Neurosurgery       Date:  2009-01       Impact factor: 4.654

9.  Combined intravenous and intra-arterial recanalization for acute ischemic stroke: the Interventional Management of Stroke Study.

Authors: 
Journal:  Stroke       Date:  2004-03-11       Impact factor: 7.914

10.  Mechanical thrombectomy for acute ischemic stroke: final results of the Multi MERCI trial.

Authors:  Wade S Smith; Gene Sung; Jeffrey Saver; Ronald Budzik; Gary Duckwiler; David S Liebeskind; Helmi L Lutsep; Marilyn M Rymer; Randall T Higashida; Sidney Starkman; Y Pierre Gobin; Donald Frei; Thomas Grobelny; Frank Hellinger; Dan Huddle; Chelsea Kidwell; Walter Koroshetz; Michael Marks; Gary Nesbit; Isaac E Silverman
Journal:  Stroke       Date:  2008-02-28       Impact factor: 7.914

View more
  22 in total

1.  First-In-Man Procedural Experience with the Novel EmboTrap® Revascularization Device for the Treatment of Ischemic Stroke-A European Multicenter Series.

Authors:  C Kabbasch; A Mpotsaris; T Liebig; M Söderman; M Holtmannspötter; M Cronqvist; J Thornton; V Mendes Pereira; T Andersson
Journal:  Clin Neuroradiol       Date:  2014-11-01       Impact factor: 3.649

2.  Mechanical thrombectomy compared to local-intraarterial thrombolysis in carotid T and middle cerebral artery occlusions: a single center experience.

Authors:  M Möhlenbruch; M Seifert; T Okulla; U Wüllner; D R Hadizadeh; M Nelles; S Greschus; K Wilhelm; H H Schild; T Klockgether; H Urbach
Journal:  Clin Neuroradiol       Date:  2011-10-05       Impact factor: 3.649

3.  Solitaire flow-restoration device for treatment of acute ischemic stroke: safety and recanalization efficacy study in a swine vessel occlusion model.

Authors:  R Jahan
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

4.  In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion.

Authors:  P Mordasini; N Frabetti; J Gralla; G Schroth; U Fischer; M Arnold; C Brekenfeld
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

5.  Use of a complete autologous blood recovery system (the Sorin Xtra® Autotransfusion System) during mechanical thrombectomy of extensive cerebral venous sinus thrombosis.

Authors:  C Castaño; C Cubells; S Remollo; M R García-Sort; M Terceño
Journal:  Interv Neuroradiol       Date:  2017-07-21       Impact factor: 1.610

6.  Future trials of endovascular mechanical recanalisation therapy in acute ischemic stroke patients: a position paper endorsed by ESMINT and ESNR : part I: Current situation and major research questions.

Authors:  Jens Fiehler; Michael Söderman; Francis Turjman; Philip M White; Søren Jacob Bakke; Salvatore Mangiafico; Rüdiger von Kummer; Mario Muto; Christophe Cognard; Jan Gralla
Journal:  Neuroradiology       Date:  2012-09-05       Impact factor: 2.804

7.  Impact of retrievable stents on acute ischemic stroke treatment.

Authors:  C Brekenfeld; G Schroth; P Mordasini; U Fischer; M-L Mono; A Weck; M Arnold; M El-Koussy; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-12       Impact factor: 3.825

8.  Inadvertent Stent Retriever Detachment: A Multicenter Case Series and Review of Device Experience FDA Reports.

Authors:  Hesham Masoud; Thanh N Nguyen; Coleman O Martin; William E Holloway; Sudheer Ambekar; Dileep R Yavagal; Diogo C Haussen; Raul Nogueira; Diego J Lozano; Ajit Puri; Ayman Quateen; Daniela Iancu; Michael G Abraham; Michael Chen; Sonal Mehta; Tim Malisch; Franklin Marden; Robin Novakovic; Daniel Roy; Alain Weill; Alexander M Norbash
Journal:  Interv Neurol       Date:  2015-11-20

Review 9.  Endovascular Stroke Therapy.

Authors:  Wade S Smith
Journal:  Neurotherapeutics       Date:  2019-04       Impact factor: 7.620

10.  [Technical standards for the interventional treatment of acute ischemic stroke].

Authors:  M A Möhlenbruch; M Bendszus
Journal:  Nervenarzt       Date:  2015-10       Impact factor: 1.214

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.