Literature DB >> 20966052

In vivo evaluation of the first dedicated combined flow-restoration and mechanical thrombectomy device in a swine model of acute vessel occlusion.

P Mordasini1, N Frabetti, J Gralla, G Schroth, U Fischer, M Arnold, C Brekenfeld.   

Abstract

BACKGROUND AND
PURPOSE: The use of self-expanding retrievable stents is an emerging and promising treatment strategy for acute stroke treatment. The concept combines the advantages of stent deployment with immediate flow-restoration and of mechanical thrombectomy with definitive thrombus removal. The present study was performed to gain more knowledge about the principle of combined flow restoration and thrombectomy in an established animal model using radiopaque thrombi evaluating efficiency, thrombus-device interaction and possible complications of the first dedicated flow-restoration and mechanical thrombectomy device.
MATERIALS AND METHODS: The Solitaire FR (4 × 20 mm) was evaluated in 15 vessel occlusions in an established animal model in swine. Flow-restoration effect at T0, T5, and T10; recanalization rate after retrieval; thromboembolic events; and complications were assessed. Radiopaque thrombi (10-mm length) were used for visualization of thrombus-device interaction during application and retrieval.
RESULTS: Immediate flow restoration was achieved in 80% of occlusions. Mean percentage of recanalization compared with the initial vessel diameter at T0 was 30.8%; at T5, 30.7%; and at T10, 25.4%. Re-occlusion occurred in 20.0% between T0 and T5 and in 13.3% between T5 and T10. Complete recanalization (TICI 3) after retrieval was achieved in 86.7%. In 2 cases (13.3%), partial recanalization was achieved, with the remaining thrombus in a side branch (TICI 2b). No thromboembolic event was observed. The assessment of thrombus-device interaction illustrated the compression of the thrombus against the vessel wall during deployment leading to partial flow restoration. During retrieval, the thrombus was retained by the stent struts even during the passage of vessel curvatures.
CONCLUSIONS: The Solitaire FR is a safe and effective combined flow-restoration and thrombectomy device in vivo. Partial flow restoration is achieved by thrombus compression immediately after deployment, but flow restoration decreases afterward until final retrieval results in maximal recanalization.

Entities:  

Mesh:

Year:  2010        PMID: 20966052      PMCID: PMC7965706          DOI: 10.3174/ajnr.A2270

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  20 in total

1.  Self-expanding stent-assisted middle cerebral artery recanalization: technical note.

Authors:  Eric Sauvageau; Elad I Levy
Journal:  Neuroradiology       Date:  2006-04-19       Impact factor: 2.804

2.  Occlusion length is a crucial determinant of efficiency and complication rate in thrombectomy for acute ischemic stroke.

Authors:  J Gralla; M Burkhardt; G Schroth; M El-Koussy; M Reinert; K Nedeltchev; J Slotboom; C Brekenfeld
Journal:  AJNR Am J Neuroradiol       Date:  2007-11-01       Impact factor: 3.825

3.  Wingspan in-stent restenosis and thrombosis: incidence, clinical presentation, and management.

Authors:  Elad I Levy; Aquilla S Turk; Felipe C Albuquerque; David B Niemann; Beverly Aagaard-Kienitz; Lee Pride; Phil Purdy; Babu Welch; Henry Woo; Peter A Rasmussen; L Nelson Hopkins; Thomas J Masaryk; Cameron G McDougall; David J Fiorella
Journal:  Neurosurgery       Date:  2007-09       Impact factor: 4.654

4.  Navigability trumps all: stenting of acute middle cerebral artery occlusions with a new self-expandable stent.

Authors:  P T L Chiam; R M Samuelson; J Mocco; R A Hanel; A H Siddiqui; L N Hopkins; E I Levy
Journal:  AJNR Am J Neuroradiol       Date:  2008-09-03       Impact factor: 3.825

5.  Mechanical thrombectomy for acute ischemic stroke: thrombus-device interaction, efficiency, and complications in vivo.

Authors:  Jan Gralla; Gerhard Schroth; Luca Remonda; Krassen Nedeltchev; Johannes Slotboom; Caspar Brekenfeld
Journal:  Stroke       Date:  2006-10-19       Impact factor: 7.914

6.  Recanalization of an acute middle cerebral artery occlusion using a self-expanding, reconstrainable, intracranial microstent as a temporary endovascular bypass.

Authors:  Michael E Kelly; Anthony J Furlan; David Fiorella
Journal:  Stroke       Date:  2008-04-03       Impact factor: 7.914

7.  Self-expanding stents for recanalization of acute cerebrovascular occlusions.

Authors:  E I Levy; R Mehta; R Gupta; R A Hanel; A J Chamczuk; D Fiorella; H H Woo; F C Albuquerque; T G Jovin; M B Horowitz; L N Hopkins
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

8.  Temporary stenting and retrieval of the self-expandable, intracranial stent in acute middle cerebral artery occlusion.

Authors:  Sang Hyun Suh; Kyung-Yul Lee; Chang Ki Hong; Byung Moon Kim; Chang-Hyun Kim; Tae-Sub Chung; Dong Ik Kim
Journal:  Neuroradiology       Date:  2009-05-08       Impact factor: 2.804

9.  Mechanical thromboembolectomy for acute ischemic stroke: comparison of the catch thrombectomy device and the Merci Retriever in vivo.

Authors:  Caspar Brekenfeld; Gerhard Schroth; Marwan El-Koussy; Krassen Nedeltchev; Michael Reinert; Johannes Slotboom; Jan Gralla
Journal:  Stroke       Date:  2008-02-28       Impact factor: 7.914

10.  Interventional acute ischemic stroke therapy with intracranial self-expanding stent.

Authors:  Osama O Zaidat; Thomas Wolfe; Syed I Hussain; John R Lynch; Rishi Gupta; Joanna Delap; Michel T Torbey; Brian-Fred Fitzsimmons
Journal:  Stroke       Date:  2008-06-12       Impact factor: 7.914

View more
  24 in total

1.  A comparison of 2 stroke devices: the new Aperio clot-removal device and the solitaire AB/FR.

Authors:  C Roth; D Junk; P Papanagiotou; A Keuler; H Körner; M Schumacher; W Reith
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

2.  Technical feasibility and application of mechanical thrombectomy with the Solitaire FR Revascularization Device in acute basilar artery occlusion.

Authors:  P Mordasini; C Brekenfeld; J V Byrne; U Fischer; M Arnold; M R Heldner; R Lüdi; H P Mattle; G Schroth; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2012-06-21       Impact factor: 3.825

3.  Retrograde semi-retrieval technique for combined stentriever plus aspiration thrombectomy in acute ischemic stroke.

Authors:  Ming Wei; Zhiqiang Wei; Xin Li; Hong Li
Journal:  Interv Neuroradiol       Date:  2017-03-07       Impact factor: 1.610

4.  Flat panel detector computed tomography for the interaction between contrast-enhanced thrombi and stent retrievers in stroke therapy: a pilot study.

Authors:  K J Wenger; J Berkefeld; M Wagner
Journal:  Clin Neuroradiol       Date:  2013-08-15       Impact factor: 3.649

5.  Experimental evaluation of immediate recanalization effect and recanalization efficacy of a new thrombus retriever for acute stroke treatment in vivo.

Authors:  P Mordasini; C Brekenfeld; J V Byrne; U Fischer; M Arnold; S Jung; G Schroth; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2012-07-26       Impact factor: 3.825

6.  Histopathologic evaluation of arterial wall response to 5 neurovascular mechanical thrombectomy devices in a swine model.

Authors:  B Gory; D Bresson; I Kessler; M L Perrin; A Guillaudeau; K Durand; S Ponsonnard; C Couquet; C Yardin; C Mounayer
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-28       Impact factor: 3.825

Review 7.  What is meant by "TICI"?

Authors:  J E Fugate; A M Klunder; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2013-04-11       Impact factor: 3.825

8.  Impact of retrievable stents on acute ischemic stroke treatment.

Authors:  C Brekenfeld; G Schroth; P Mordasini; U Fischer; M-L Mono; A Weck; M Arnold; M El-Koussy; J Gralla
Journal:  AJNR Am J Neuroradiol       Date:  2011-05-12       Impact factor: 3.825

9.  Evaluation of the Solitaire system in a canine arterial thromboembolic occlusion model: is it safe for the endothelium?

Authors:  Soonchan Park; Seon Moon Hwang; Joon Seon Song; Dae Chul Suh; Deok Hee Lee
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

10.  Frequency and relevance of anterior cerebral artery embolism caused by mechanical thrombectomy of middle cerebral artery occlusion.

Authors:  W Kurre; K Vorlaender; M Aguilar-Pérez; E Schmid; H Bäzner; H Henkes
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-07       Impact factor: 3.825

View more