Literature DB >> 20437213

The platinum chromium element stent platform: from alloy, to design, to clinical practice.

Ian B A Menown1, Rebecca Noad, Eulogio J Garcia, Ian Meredith.   

Abstract

Despite advances in polymer and drug technology, the underlying stent platform remains a key determinant of clinical outcome. A clear understanding of stent design and the differences between various stent platforms are of increasing importance for the interventional cardiologist. Reduction in stent strut thickness has been associated with improved stent deliverability, improved procedural outcome, and lower rates of subsequent restenosis. Newer-generation 316L-SS stent designs have enabled reduced strut thickness while retaining radial strength and minimizing recoil, but with significant loss of radiopacity, leading to reduced visibility. Cobalt chromium alloys have enabled a reduction in stent strut thickness to around 80-90 mm while retaining modest radiopacity, but due to higher elastic properties, have been associated with greater stent recoil. Development of a novel 33% platinum chromium alloy with high radial strength and high radiopacity has enabled design of a new, thin-strut, flexible, easily visualized, and highly trackable stent platform, the use of which is further illustrated in several clinical case descriptions.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20437213     DOI: 10.1007/s12325-010-0022-9

Source DB:  PubMed          Journal:  Adv Ther        ISSN: 0741-238X            Impact factor:   3.845


  21 in total

1.  Percutaneous coronary intervention, a historical perspective looking to the future.

Authors:  Johan Bennett; Christophe Dubois
Journal:  J Thorac Dis       Date:  2013-06       Impact factor: 2.895

2.  Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.

Authors:  Hirofumi Ohtani; Shigeki Kimura; Tomoyo Sugiyama; Keiichi Hishikari; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Hiroyuki Hikita; Takashi Ashikaga; Atsushi Takahashi; Mitsuaki Isobe
Journal:  Int J Cardiovasc Imaging       Date:  2016-10-19       Impact factor: 2.357

3.  In vivo assessment of stent recoil of biodegradable polymer-coated cobalt-chromium sirolimus-eluting coronary stent system.

Authors:  Atul D Abhyankar; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27

4.  Needles in Our Technology Haystacks: Defining Efficacy Is Easy, Characterizing Complications Is the Challenge.

Authors:  Elazer R Edelman; Pei-Jiang Wang
Journal:  Circ Cardiovasc Interv       Date:  2017-11       Impact factor: 6.546

5.  Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2014-10-28       Impact factor: 2.357

6.  Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.

Authors:  Shun Nakamura; Shigeki Kimura; Shun Nakagama; Toru Misawa; Masafumi Mizusawa; Kazuto Hayasaka; Yosuke Yamakami; Keisuke Kojima; Yuichiro Sagawa; Keiichi Hishikari; Hiroyuki Hikita; Atsushi Takahashi; Kenzo Hirao
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-29       Impact factor: 2.357

7.  Long-Term Safety and Efficacy of Platinum Chromium Everolimus-Eluting Stents in Coronary Artery Disease: 5-Year Results From the PLATINUM Trial.

Authors:  Christopher R Kelly; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Abram Rabinowitz; Didier Carrié; Vincent Pompili; Alain Bouchard; Shigeru Saito; Dominic J Allocco; Keith D Dawkins; Gregg W Stone
Journal:  JACC Cardiovasc Interv       Date:  2017-12-11       Impact factor: 11.195

8.  Clinical, angiographic and procedural characteristics of longitudinal stent deformation.

Authors:  A Guler; Y Guler; E Acar; S M Aung; S C Efe; A Kilicgedik; C Y Karabay; S Barutcu; M K Tigen; S Pala; A İzgi; A M Esen; C Kirma
Journal:  Int J Cardiovasc Imaging       Date:  2016-05-19       Impact factor: 2.357

9.  Everolimus-eluting stents: update on current clinical studies.

Authors:  Dominic J Allocco; Anita A Joshi; Keith D Dawkins
Journal:  Med Devices (Auckl)       Date:  2011-07-26

10.  A novel platinum chromium everolimus-eluting stent for the treatment of coronary artery disease.

Authors:  Johan Bennett; Christophe Dubois
Journal:  Biologics       Date:  2013-06-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.