Literature DB >> 31359232

Impact of lesion angle on optical coherence tomography findings and clinical outcomes after drug-eluting stent implantation in curved vessels.

Shun Nakamura1, Shigeki Kimura2, Shun Nakagama1, Toru Misawa1, Masafumi Mizusawa1, Kazuto Hayasaka1, Yosuke Yamakami1, Keisuke Kojima1, Yuichiro Sagawa1, Keiichi Hishikari1, Hiroyuki Hikita1, Atsushi Takahashi1, Kenzo Hirao3.   

Abstract

Tortuous coronary lesions are associated with adverse outcomes after implantation of bare metal or first-generation drug-eluting stents (DESs). We investigated the impact of lesion angle on vessel wall injuries and stent apposition as assessed by optical coherence tomography (OCT) after second- and newer-generation DES implantation. We investigated 95 de novo lesions treated with a single DES (62 platinum-chromium everolimus-eluting stents and 33 bioresorbable-polymer sirolimus-eluting stents). Post-intervention OCT findings were compared between angled lesions (≥ 45°; n = 33) and non-angled lesions (< 45°; n = 62). The 12-month clinical outcomes were also compared between the groups. Cross-sectional OCT analysis revealed that compared to non-angled lesions, angled ones had a significantly higher incidence of intra-stent dissection around the centre of the angle (19.7% vs. 10.8%, p = 0.01) and incomplete stent apposition (ISA) in the distal and proximal sub-segments (10.0% vs. 4.1%, p = 0.002; 15.3% vs. 7.9%, p < 0.001, respectively). Strut-based analysis also showed that angled lesions demonstrated a higher rate of malapposed strut in the distal and proximal sub-segments (3.0% vs. 0.9%, p < 0.001; 4.3% vs. 1.8%, p < 0.001, respectively). The 12 month clinical outcomes were comparable between the groups. Compared to non-angled lesions, angled coronary lesions were associated with a higher incidence of intra-stent dissection and ISA on post-intervention OCT after implantation of second- and newer-generation DESs.

Entities:  

Keywords:  Angled lesion; Drug-eluting stent; Optical coherence tomography; Quantitative coronary angiography

Year:  2019        PMID: 31359232     DOI: 10.1007/s10554-019-01679-6

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

1.  Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators.

Authors:  M Gyöngyösi; P Yang; A Khorsand; D Glogar
Journal:  J Am Coll Cardiol       Date:  2000-05       Impact factor: 24.094

Review 2.  The platinum chromium element stent platform: from alloy, to design, to clinical practice.

Authors:  Ian B A Menown; Rebecca Noad; Eulogio J Garcia; Ian Meredith
Journal:  Adv Ther       Date:  2010-04-29       Impact factor: 3.845

3.  Stent expansion in curved vessel and their interactions: a finite element analysis.

Authors:  Wei Wu; Wei-Qiang Wang; Da-Zhi Yang; Min Qi
Journal:  J Biomech       Date:  2007-01-02       Impact factor: 2.712

4.  ABSORB biodegradable stents versus second-generation metal stents: a comparison study of 100 complex lesions treated under OCT guidance.

Authors:  Alessio Mattesini; Gioel G Secco; Gianni Dall'Ara; Matteo Ghione; Juan C Rama-Merchan; Alessandro Lupi; Nicola Viceconte; Alistair C Lindsay; Ranil De Silva; Nicolas Foin; Toru Naganuma; Serafina Valente; Antonio Colombo; Carlo Di Mario
Journal:  JACC Cardiovasc Interv       Date:  2014-07       Impact factor: 11.195

5.  Virtual bench testing of new generation coronary stents.

Authors:  Peter Mortier; Matthieu De Beule; Patrick Segers; Pascal Verdonck; Benedict Verhegghe
Journal:  EuroIntervention       Date:  2011-07       Impact factor: 6.534

6.  Impacts of lesion angle on incidence and distribution of acute vessel wall injuries and strut malapposition after drug-eluting stent implantation assessed by optical coherence tomography.

Authors:  Yoshiyasu Minami; Daniel S Ong; Shiro Uemura; Zhao Wang; Aaron D Aguirre; Shankha Mukhopadhyay; Tsunenari Soeda; Rocco Vergallo; Haibo Jia; Jinwei Tian; Sining Hu; Soo Joong Kim; Chang-Bum Park; Harold L Dauerman; Stephen Lee; Ik-Kyung Jang
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-04-29       Impact factor: 6.875

7.  Lipid-rich plaque and myocardial perfusion after successful stenting in patients with non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study.

Authors:  Atsushi Tanaka; Toshio Imanishi; Hironori Kitabata; Takashi Kubo; Shigeho Takarada; Takashi Tanimoto; Akio Kuroi; Hiroto Tsujioka; Hideyuki Ikejima; Kenichi Komukai; Hideaki Kataiwa; Keishi Okouchi; Manabu Kashiwaghi; Kohei Ishibashi; Hiroki Matsumoto; Kazushi Takemoto; Nobuo Nakamura; Kumiko Hirata; Masato Mizukoshi; Takashi Akasaka
Journal:  Eur Heart J       Date:  2009-04-21       Impact factor: 29.983

8.  Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.

Authors:  Takumi Inoue; Toshiro Shinke; Hiromasa Otake; Masayuki Nakagawa; Hirotoshi Hariki; Tsuyoshi Osue; Masamichi Iwasaki; Yu Taniguchi; Ryo Nishio; Noritoshi Hiranuma; Akihide Konishi; Hiroto Kinutani; Masaru Kuroda; Ken-ichi Hirata
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-19       Impact factor: 2.357

9.  Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging: The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months).

Authors:  Bernard Chevalier; Pieter C Smits; Didier Carrié; Julinda Mehilli; Ad J Van Boven; Evelyn Regar; Fadi J Sawaya; Daniel Chamié; Adriaan O Kraaijeveld; Thomas Hovasse; Georgios J Vlachojannis
Journal:  Circ Cardiovasc Interv       Date:  2017-12       Impact factor: 6.546

10.  Non-culprit plaque characteristics in acute coronary syndrome patients with raised hemoglobinA1c: an intravascular optical coherence tomography study.

Authors:  Shaotao Zhang; Jiannan Dai; Haibo Jia; Sining Hu; Hongwei Du; Ning Li; Yongpeng Zou; Yanan Zou; Shenhong Jing; Yan Wang; Rong Sun; Bo Yu
Journal:  Cardiovasc Diabetol       Date:  2018-06-15       Impact factor: 9.951

View more
  1 in total

1.  Cardiovascular imaging 2019 in the International Journal of Cardiovascular Imaging.

Authors:  Johan H C Reiber; Gabriel T R Pereira; Luis A P Dallan; Hiram G Bezerra; Johan De Sutter; Arthur E Stillman; Nico R L Van de Veire; Joachim Lotz
Journal:  Int J Cardiovasc Imaging       Date:  2020-05       Impact factor: 2.357

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.