Literature DB >> 25345751

Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.

Byeong-Keuk Kim1, Dong-Ho Shin, Jung-Sun Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong.   

Abstract

No randomized data exist regarding optical coherence tomography (OCT) evaluation immediately post-procedure and at the 3-month follow-up for platinum-chromium everolimus-eluting stents (PtCr-EES) versus cobalt-chromium everolimus-eluting stents (CoCr-EES). A total of 100 patients were randomly assigned to undergo PtCr-EES (n = 51) or CoCr-EES (n = 49) implantation. OCT was serially evaluated after stent deployment with nominal pressure and immediately post-procedure, and 3-month follow-up. The primary endpoint was the percentage of malapposed strut after nominal pressure and immediately post-procedure. Compared to the CoCr-EES, the PtCr-EES showed a lower tendency of percent malapposed strut at nominal pressure [median value (interquartile range); 4.1 % (0.5-11.7) vs. 7.6 % (2.9-13.7), p = 0.082] and immediately post-procedure [1.2 % (0-3.4) vs. 2.5 % (0.7-5.3), p = 0.051]. The percentage of cross sections with any malapposed struts was significantly lower with PtCr-EES at nominal pressure [15.0 % (5.6-39.0) vs. 23.8 % (18.2-44.4), p = 0.036] and immediately post-procedure [6.5 % (0-15.3) vs. 10.5 % (7.1-20.0), p = 0.026]. At the 3-month follow-up, both PtCr-EES and CoCr-EES showed comparable percentages of malapposed struts (0 vs. 0 %, respectively, p = 0.332) and uncovered struts (5.3 vs. 4.7 %, respectively, p = 0.829). We found a significant correlation between the immediate post-procedural percentage of malapposed struts versus the percentage of uncovered struts (r = 0.430, p < 0.001) at the 3-month follow-up. Compared to the CoCr-EES, the PtCr-EES shows a lower tendency toward a lower percentage of malapposed struts but no significant difference in strut coverage at the 3-month follow-up. The percentage of malapposed struts immediately post-procedure was correlated with strut coverage at the 3-month follow-up.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25345751     DOI: 10.1007/s10554-014-0557-y

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  26 in total

1.  Initial clinical experience with an everolimus eluting platinum chromium stent (Promus Element) in unselected patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR).

Authors:  Giovanna Sarno; Bo Lagerqvist; Jörg Carlsson; Göran Olivecrona; Johan Nilsson; Fredrik Calais; Matthias Götberg; Tage Nilsson; Iwar Sjögren; Stefan James
Journal:  Int J Cardiol       Date:  2012-01-13       Impact factor: 4.164

2.  Comparison of zotarolimus-eluting and everolimus-eluting coronary stents.

Authors:  Patrick W Serruys; Sigmund Silber; Scot Garg; Robert Jan van Geuns; Gert Richardt; Pawel E Buszman; Henning Kelbaek; Adrianus Johannes van Boven; Sjoerd H Hofma; Axel Linke; Volker Klauss; William Wijns; Carlos Macaya; Philippe Garot; Carlo DiMario; Ganesh Manoharan; Ran Kornowski; Thomas Ischinger; Antonio Bartorelli; Jacintha Ronden; Marco Bressers; Pierre Gobbens; Manuela Negoita; Frank van Leeuwen; Stephan Windecker
Journal:  N Engl J Med       Date:  2010-06-16       Impact factor: 91.245

3.  Late stent malapposition after drug-eluting stent implantation: an intravascular ultrasound analysis with long-term follow-up.

Authors:  Myeong-Ki Hong; Gary S Mintz; Cheol Whan Lee; Duk-Woo Park; Kyoung-Min Park; Bong-Ki Lee; Young-Hak Kim; Jong-Min Song; Ki-Hoon Han; Duk-Hyun Kang; Sang-Sig Cheong; Jae-Kwan Song; Jae-Joong Kim; Seong-Wook Park; Seung-Jung Park
Journal:  Circulation       Date:  2006-01-24       Impact factor: 29.690

4.  Incidence of diffuse and focal chronic stent recoil after implantation of current generation bare-metal and drug-eluting stents.

Authors:  Bon-Kwon Koo; Katsuhisa Waseda; Junya Ako; Takao Hasegawa; Takao Shimohama; Daisaku Nakatani; Hiromasa Otake; Masao Yamasaki; Ryota Sakurai; Ichizo Tsujino; Yasuhiro Honda; Peter J Fitzgerald
Journal:  Int J Cardiol       Date:  2009-01-26       Impact factor: 4.164

5.  Impact of different stent alloys on human vascular response to everolimus-eluting stent: an optical coherence tomography study: the OCTEVEREST.

Authors:  Giulio Guagliumi; Davide Capodanno; Hideyuki Ikejima; Hiram G Bezerra; Vasile Sirbu; Giuseppe Musumeci; Luigi Fiocca; Nikoloz Lortkipanidze; Angelina Vassileva; Satoko Tahara; Orazio Valsecchi; Marco A Costa
Journal:  Catheter Cardiovasc Interv       Date:  2012-05-02       Impact factor: 2.692

6.  Intravascular ultrasound assessment of cobalt chromium versus stainless steel drug-eluting stent expansion.

Authors:  Yong He; Akiko Maehara; Gary S Mintz; Harpreet Bharaj; Celia Castellanos; Srinivas Kesanakurthy; Xiaofan Wu; Ning Guo; So-Yeon Choi; Martin B Leon; Gregg W Stone; Roxana Mehran; Leroy E Rabbani; Jeffrey W Moses
Journal:  Am J Cardiol       Date:  2010-05-01       Impact factor: 2.778

7.  A prospective, randomized evaluation of a novel everolimus-eluting coronary stent: the PLATINUM (a Prospective, Randomized, Multicenter Trial to Assess an Everolimus-Eluting Coronary Stent System [PROMUS Element] for the Treatment of Up to Two de Novo Coronary Artery Lesions) trial.

Authors:  Gregg W Stone; Paul S Teirstein; Ian T Meredith; Bruno Farah; Christophe L Dubois; Robert L Feldman; Joseph Dens; Nobuhisa Hagiwara; Dominic J Allocco; Keith D Dawkins
Journal:  J Am Coll Cardiol       Date:  2011-04-04       Impact factor: 24.094

8.  Randomized comparison of everolimus-eluting and paclitaxel-eluting stents: two-year clinical follow-up from the Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients with de novo Native Coronary Artery Lesions (SPIRIT) III trial.

Authors:  Gregg W Stone; Mark Midei; William Newman; Mark Sanz; James B Hermiller; Jerome Williams; Naim Farhat; Ronald Caputo; Nicholas Xenopoulos; Robert Applegate; Paul Gordon; Roseann M White; Krishnankutty Sudhir; Donald E Cutlip; John L Petersen
Journal:  Circulation       Date:  2009-01-26       Impact factor: 29.690

9.  Incidences, predictors, and clinical outcomes of acute and late stent malapposition detected by optical coherence tomography after drug-eluting stent implantation.

Authors:  Eui Im; Byeong-Keuk Kim; Young-Guk Ko; Dong-Ho Shin; Jung-Sun Kim; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Circ Cardiovasc Interv       Date:  2014-01-14       Impact factor: 6.546

10.  Randomised comparison of strut coverage between Nobori biolimus-eluting and sirolimus-eluting stents: an optical coherence tomography analysis.

Authors:  Byeong-Keuk Kim; Jinyong Ha; Gary S Mintz; Jung-Sun Kim; Dong-Ho Shin; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  EuroIntervention       Date:  2014       Impact factor: 6.534

View more
  5 in total

Review 1.  Cardiovascular imaging 2015 in the International Journal of Cardiovascular Imaging.

Authors:  Hiram G Bezerra; Ricardo A Costa; Johan H C Reiber; Paul Schoenhagen; Arthur A Stillman; Johan De Sutter; Nico R L Van de Veire
Journal:  Int J Cardiovasc Imaging       Date:  2016-05       Impact factor: 2.357

2.  Predictors and Long-Term Clinical Impact of Acute Stent Malapposition: An Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents (ADAPT-DES) Intravascular Ultrasound Substudy.

Authors:  Bin Wang; Gary S Mintz; Bernhard Witzenbichler; Cristiano F Souza; D Christopher Metzger; Michael J Rinaldi; Peter L Duffy; Giora Weisz; Thomas D Stuckey; Bruce R Brodie; Mitsuaki Matsumura; Myong-Hwa Yamamoto; Rupa Parvataneni; Ajay J Kirtane; Gregg W Stone; Akiko Maehara
Journal:  J Am Heart Assoc       Date:  2016-12-22       Impact factor: 5.501

3.  Severe Acute Stent Malapposition After Drug-Eluting Stent Implantation: Effects on Long-Term Clinical Outcomes.

Authors:  Seung-Yul Lee; Eui Im; Sung-Jin Hong; Chul-Min Ahn; Jung-Sun Kim; Byeong-Keuk Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  J Am Heart Assoc       Date:  2019-06-25       Impact factor: 5.501

4.  Impact of diabetes mellitus on the early-phase arterial healing after drug-eluting stent implantation.

Authors:  Takayuki Ishihara; Yohei Sotomi; Takuya Tsujimura; Osamu Iida; Tomoaki Kobayashi; Yuma Hamanaka; Takashi Omatsu; Yasushi Sakata; Yoshiharu Higuchi; Toshiaki Mano
Journal:  Cardiovasc Diabetol       Date:  2020-12-02       Impact factor: 9.951

5.  Randomized Comparison of Strut Coverage between Ticagrelor and Clopidogrel in Acute Myocardial Infarction at 3-Month Optical Coherence Tomography.

Authors:  Choongki Kim; Byeong Keuk Kim; Sung Jin Hong; Chul Min Ahn; Jung Sun Kim; Young Guk Ko; Donghoon Choi; Myeong Ki Hong; Yangsoo Jang
Journal:  Yonsei Med J       Date:  2018-07       Impact factor: 2.759

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.