MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation.

Akbar Alipour, Eric S Meyer, Charles L Dumoulin, Ronald D Watkins, Hassan Elahi, Wolfgang Loew, Jeffrey Schweitzer, Gregory Olson, Yue Chen, Susumu Tao, Michael Guttman, Aravindan Kolandaivelu, Henry R Halperin, Ehud J Schmidt.   

Abstract

OBJECTIVE: Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). <br> METHOD: MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. <br> RESULTS: Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. <br> CONCLUSION: MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE: MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.

Entities:  

Mesh:

Year:  2019        PMID: 31535979      PMCID: PMC7341984          DOI: 10.1109/TBME.2019.2941460

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  29 in total

1.  Optimization of NMR receiver bandwidth by inductive coupling.

Authors:  A Raad; L Darrasse
Journal:  Magn Reson Imaging       Date:  1992       Impact factor: 2.546

2.  Modeling of radio-frequency induced currents on lead wires during MR imaging using a modified transmission line method.

Authors:  Volkan Acikel; Ergin Atalar
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Phase-field dithering for active catheter tracking.

Authors:  Charles L Dumoulin; Richard P Mallozzi; Robert D Darrow; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

4.  Miniaturizing Floating Traps to Increase RF Safety of Magnetic-Resonance-Guided Percutaneous Procedures.

Authors:  Gregory H Griffin; Kevan J T Anderson; Graham A Wright
Journal:  IEEE Trans Biomed Eng       Date:  2017-02       Impact factor: 4.538

5.  Fractional Flow Reserve, Coronary Pressure Wires, and Drift.

Authors:  Nico Hj Pijls; Bernard De Bruyne
Journal:  Circ J       Date:  2016-07-12       Impact factor: 2.993

6.  Vascular interventions guided by ultrafast MR imaging: evaluation of different materials.

Authors:  V D Köchli; G C McKinnon; E Hofmann; G K von Schulthess
Journal:  Magn Reson Med       Date:  1994-03       Impact factor: 4.668

7.  Real-time active MR-tracking of metallic stylets in MR-guided radiation therapy.

Authors:  Wei Wang; Charles L Dumoulin; Akila N Viswanathan; Zion T H Tse; Alireza Mehrtash; Wolfgang Loew; Isaiah Norton; Junichi Tokuda; Ravi T Seethamraju; Tina Kapur; Antonio L Damato; Robert A Cormack; Ehud J Schmidt
Journal:  Magn Reson Med       Date:  2014-06-05       Impact factor: 4.668

8.  Magnetic resonance assessment of the substrate for inducible ventricular tachycardia in nonischemic cardiomyopathy.

Authors:  Saman Nazarian; David A Bluemke; Albert C Lardo; Menekhem M Zviman; Stanley P Watkins; Timm L Dickfeld; Glenn R Meininger; Ariel Roguin; Hugh Calkins; Gordon F Tomaselli; Robert G Weiss; Ronald D Berger; João A C Lima; Henry R Halperin
Journal:  Circulation       Date:  2005-11-01       Impact factor: 29.690

9.  Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans.

Authors:  Philipp Sommer; Matthias Grothoff; Charlotte Eitel; Thomas Gaspar; Christopher Piorkowski; Matthias Gutberlet; Gerhard Hindricks
Journal:  Europace       Date:  2012-07-31       Impact factor: 5.214

10.  Radiofrequency Ablation, MR Thermometry, and High-Spatial-Resolution MR Parametric Imaging with a Single, Minimally Invasive Device.

Authors:  M Arcan Ertürk; Shashank Sathyanarayana Hegde; Paul A Bottomley
Journal:  Radiology       Date:  2016-05-26       Impact factor: 11.105

View more
  3 in total

1.  MR-Tracked Deflectable Stylet for Gynecologic Brachytherapy.

Authors:  Anthony L Gunderman; Ehud J Schmidt; Marc Morcos; Junichi Tokuda; Ravi T Seethamraju; Henry R Halperin; Akila N Viswanathan; Yue Chen
Journal:  IEEE ASME Trans Mechatron       Date:  2021-03-09       Impact factor: 5.303

2.  A 20-gauge active needle design with thin-film printed circuitry for interventional MRI at 0.55T.

Authors:  Dursun Korel Yildirim; Christopher Bruce; Dogangun Uzun; Toby Rogers; Kendall O'Brien; Rajiv Ramasawmy; Adrienne Campbell-Washburn; Daniel A Herzka; Robert J Lederman; Ozgur Kocaturk
Journal:  Magn Reson Med       Date:  2021-04-16       Impact factor: 3.737

3.  Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T.

Authors:  Ehud J Schmidt; Gregory Olson; Junichi Tokuda; Akbar Alipour; Ronald D Watkins; Eric M Meyer; Hassan Elahi; William G Stevenson; Jeffrey Schweitzer; Charles L Dumoulin; Thomas Johnson; Aravindan Kolandaivelu; Wolfgang Loew; Henry R Halperin
Journal:  Magn Reson Med       Date:  2022-02-10       Impact factor: 3.737

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.