Literature DB >> 23580479

Voltage-based device tracking in a 1.5 Tesla MRI during imaging: initial validation in swine models.

Ehud J Schmidt1, Zion T H Tse, Tobias R Reichlin, Gregory F Michaud, Ronald D Watkins, Kim Butts-Pauly, Raymond Y Kwong, William Stevenson, Jeffrey Schweitzer, Israel Byrd, Charles L Dumoulin.   

Abstract

PURPOSE: Voltage-based device-tracking (VDT) systems are commonly used for tracking invasive devices in electrophysiological cardiac-arrhythmia therapy. During electrophysiological procedures, electro-anatomic mapping workstations provide guidance by integrating VDT location and intracardiac electrocardiogram information with X-ray, computerized tomography, ultrasound, and MR images. MR assists navigation, mapping, and radiofrequency ablation. Multimodality interventions require multiple patient transfers between an MRI and the X-ray/ultrasound electrophysiological suite, increasing the likelihood of patient-motion and image misregistration. An MRI-compatible VDT system may increase efficiency, as there is currently no single method to track devices both inside and outside the MRI scanner.
METHODS: An MRI-compatible VDT system was constructed by modifying a commercial system. Hardware was added to reduce MRI gradient-ramp and radiofrequency unblanking pulse interference. VDT patches and cables were modified to reduce heating. Five swine cardiac VDT electro-anatomic mapping interventions were performed, navigating inside and thereafter outside the MRI.
RESULTS: Three-catheter VDT interventions were performed at >12 frames per second both inside and outside the MRI scanner with <3 mm error. Catheters were followed on VDT- and MRI-derived maps. Simultaneous VDT and imaging was possible in repetition time >32 ms sequences with <0.5 mm errors, and <5% MRI signal-to-noise ratio (SNR) loss. At shorter repetition times, only intracardiac electrocardiogram was reliable. Radiofrequency heating was <1.5°C.
CONCLUSION: An MRI-compatible VDT system is feasible.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2014        PMID: 23580479      PMCID: PMC3884036          DOI: 10.1002/mrm.24742

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

1.  Ablation of atrial fibrillation using novel 4-dimensional catheter tracking within autoregistered left atrial angiograms.

Authors:  Sascha Rolf; Philipp Sommer; Thomas Gaspar; Silke John; Arash Arya; Gerhard Hindricks; Christopher Piorkowski
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-07-07

2.  Characterization of acute and subacute radiofrequency ablation lesions with nonenhanced magnetic resonance imaging.

Authors:  Timm Dickfeld; Ritsushi Kato; Menekem Zviman; Saman Nazarian; Jun Dong; Hiroshi Ashikaga; Albert C Lardo; Ronald D Berger; Hugh Calkins; Henry Halperin
Journal:  Heart Rhythm       Date:  2006-11-01       Impact factor: 6.343

3.  Technology preview: X-ray fused with magnetic resonance during invasive cardiovascular procedures.

Authors:  Luis F Gutiérrez; Ranil de Silva; Cengizhan Ozturk; Merdim Sonmez; Annette M Stine; Amish N Raval; Venkatesh K Raman; Vandana Sachdev; Ronnier J Aviles; Myron A Waclawiw; Elliot R McVeigh; Robert J Lederman
Journal:  Catheter Cardiovasc Interv       Date:  2007-11-15       Impact factor: 2.692

4.  Development of an electrophysiology (EP)-enabled intracardiac ultrasound catheter integrated with NavX 3-dimensional electrofield mapping for guiding cardiac EP interventions: experimental studies.

Authors:  Xiao Kui Li; James Pemberton; Kai Thomenius; Aaron Dentinger; Robert I Lowe; Muhammad Ashraf; K Kirk Shung; Raymond Chia; Douglas N Stephens; Matthew O'Donnell; Aman Mahajan; Seshadri Balaji; Kalyanam Shivkumar; David J Sahn
Journal:  J Ultrasound Med       Date:  2007-11       Impact factor: 2.153

5.  Long-term single procedure efficacy of catheter ablation of atrial fibrillation.

Authors:  Aamir Cheema; Chandrasekhar R Vasamreddy; Darshan Dalal; Joseph E Marine; Jun Dong; Charles A Henrikson; David Spragg; Alan Cheng; Saman Nazarian; Sunil Sinha; Henry Halperin; Ronald Berger; Hugh Calkins
Journal:  J Interv Card Electrophysiol       Date:  2006-08-05       Impact factor: 1.900

6.  Long-term safety and efficacy of circumferential ablation with pulmonary vein isolation.

Authors:  Aamir Cheema; Jun Dong; Darshan Dalal; Chandrasekhar R Vasamreddy; Joseph E Marine; Charles A Henrikson; David Spragg; Alan Cheng; Saman Nazarian; Sunil Sinha; Henry Halperin; Ronald Berger; Hugh Calkins
Journal:  J Cardiovasc Electrophysiol       Date:  2006-10

7.  Integration of cardiac CT/MR imaging with three-dimensional electroanatomical mapping to guide catheter manipulation in the left atrium: implications for catheter ablation of atrial fibrillation.

Authors:  Zachary J Malchano; Petr Neuzil; Ricardo C Cury; Godtfred Holmvang; Jiri Weichet; Ehud J Schmidt; Jeremy N Ruskin; Vivek Y Reddy
Journal:  J Cardiovasc Electrophysiol       Date:  2006-11

8.  Incidence and time course of early recovery of pulmonary vein conduction after catheter ablation of atrial fibrillation.

Authors:  Aamir Cheema; Jun Dong; Darshan Dalal; Joseph E Marine; Charles A Henrikson; David Spragg; Alan Cheng; Saman Nazarian; Kenneth Bilchick; Sunil Sinha; Daniel Scherr; Ibrahim Almasry; Henry Halperin; Ronald Berger; Hugh Calkins
Journal:  J Cardiovasc Electrophysiol       Date:  2007-04

9.  Detection of pulmonary vein and left atrial scar after catheter ablation with three-dimensional navigator-gated delayed enhancement MR imaging: initial experience.

Authors:  Dana C Peters; John V Wylie; Thomas H Hauser; Kraig V Kissinger; René M Botnar; Vidal Essebag; Mark E Josephson; Warren J Manning
Journal:  Radiology       Date:  2007-06       Impact factor: 11.105

10.  Electric fields induced in the human body by time-varying magnetic field gradients in MRI: numerical calculations and correlation analysis.

Authors:  Martin Bencsik; Richard Bowtell; Roger Bowley
Journal:  Phys Med Biol       Date:  2007-04-10       Impact factor: 3.609

View more
  4 in total

1.  Cardiac Electrophysiology Under MRI Guidance: an Emerging Technology.

Authors:  Henry Chubb; Steven E Williams; John Whitaker; James L Harrison; Reza Razavi; Mark O'Neill
Journal:  Arrhythm Electrophysiol Rev       Date:  2017-06

Review 2.  MRI use for atrial tissue characterization in arrhythmias and for EP procedure guidance.

Authors:  Ehud J Schmidt; Henry R Halperin
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-07       Impact factor: 2.357

3.  A Magnetic Resonance Imaging-Conditional External Cardiac Defibrillator for Resuscitation Within the Magnetic Resonance Imaging Scanner Bore.

Authors:  Ehud J Schmidt; Ronald D Watkins; Menekhem M Zviman; Michael A Guttman; Wei Wang; Henry A Halperin
Journal:  Circ Cardiovasc Imaging       Date:  2016-10       Impact factor: 7.792

4.  Intracardiac MR imaging (ICMRI) guiding-sheath with amplified expandable-tip imaging and MR-tracking for navigation and arrythmia ablation monitoring: Swine testing at 1.5 and 3T.

Authors:  Ehud J Schmidt; Gregory Olson; Junichi Tokuda; Akbar Alipour; Ronald D Watkins; Eric M Meyer; Hassan Elahi; William G Stevenson; Jeffrey Schweitzer; Charles L Dumoulin; Thomas Johnson; Aravindan Kolandaivelu; Wolfgang Loew; Henry R Halperin
Journal:  Magn Reson Med       Date:  2022-02-10       Impact factor: 3.737

  4 in total