Literature DB >> 2319937

Snapshot FLASH MRI. Applications to T1, T2, and chemical-shift imaging.

A Haase1.   

Abstract

Snapshot FLASH magnetic resonance imaging techniques have been developed to enable real-time imaging of MR parameters. The first realization of the method is based on a 64 X 128 FLASH tomogram acquired within 200 ms, using improved MR system hardware conditions. The soft tissue contrast obtained in FLASH MRI almost disappears by using flip angles of less than 5 degrees and repetition times of 3 ms. This work describes extensions of FLASH MRI placing conventional MR experiments before the whole imaging sequence. This creates images of any desired contrast without changing the measuring time. Examples of inversion-recovery T1, spin-echo T2, chemical-shift-selective, and spectroscopic FLASH MRI are presented. Further extensions to real-time MRI of blood vessels, diffusion coefficients, combination with two-dimensional MR spectroscopy experiments, and other nuclei are discussed.

Mesh:

Year:  1990        PMID: 2319937     DOI: 10.1002/mrm.1910130109

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  104 in total

1.  MR CAT scan: a modular approach for hybrid imaging.

Authors:  C Hillenbrand; D Hahn; A Haase; P M Jakob
Journal:  MAGMA       Date:  2000-07       Impact factor: 2.310

2.  Functional MR with use of FLASH sequences in the evaluation of the phono-articulatory tract.

Authors:  S Meduri; M Bazzocchi; C Zuiani; B Falcone; G Bertino; G Marioni
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

Review 3.  Contrast agents and cardiac MR imaging of myocardial ischemia: from bench to bedside.

Authors:  Pierre Croisille; Didier Revel; Maythem Saeed
Journal:  Eur Radiol       Date:  2006-04-22       Impact factor: 5.315

Review 4.  Principles and applications of balanced SSFP techniques.

Authors:  Klaus Scheffler; Stefan Lehnhardt
Journal:  Eur Radiol       Date:  2003-08-20       Impact factor: 5.315

5.  Fast spin-echo imaging of the abdomen during breath-holding: an alternative to RASE and other fast imaging techniques.

Authors:  R C Nelson; J L Chezmar
Journal:  Gastrointest Radiol       Date:  1992

6.  Distinction in coherent neural network between resting and working brain states.

Authors:  Xiao Liu; Xiao-Hong Zhu; Wei Chen
Journal:  Brain Connect       Date:  2011-11-15

7.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

8.  T1 weighted brain images at 7 Tesla unbiased for Proton Density, T2* contrast and RF coil receive B1 sensitivity with simultaneous vessel visualization.

Authors:  Pierre-François Van de Moortele; Edwards J Auerbach; Cheryl Olman; Essa Yacoub; Kâmil Uğurbil; Steen Moeller
Journal:  Neuroimage       Date:  2009-02-20       Impact factor: 6.556

9.  Perfusional deficit and the dynamics of cerebral edemas in experimental traumatic brain injury using perfusion and diffusion-weighted magnetic resonance imaging.

Authors:  Anne Pasco; Laurent Lemaire; Florence Franconi; Yann Lefur; Fanny Noury; Jean-Paul Saint-André; Jean-Pierre Benoit; Patrick J Cozzone; Jean-Jacques Le Jeune
Journal:  J Neurotrauma       Date:  2007-08       Impact factor: 5.269

10.  In vitro Gd-DTPA relaxometry studies in oxygenated venous human blood and aqueous solution at 3 and 7 T.

Authors:  Chaitanya Kalavagunta; Shalom Michaeli; Gregory J Metzger
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.