Design and computational fluid dynamics investigation of a personal, high flow inhalable sampler.

T Renée Anthony1, Andrea C Landázuri, Mike Van Dyke, John Volckens.   

Abstract

The objective of this research was to develop an inlet to meet the inhalable sampling criterion at 10 l min(-1) flow using the standard, 37-mm cassette. We designed a porous head for this cassette and evaluated its performance using computational fluid dynamics (CFD) modeling. Particle aspiration efficiency was simulated in a wind tunnel environment at 0.4 m s(-1) freestream velocity for a facing-the-wind orientation, with sampler oriented at both 0 degrees (horizontal) and 30 degrees down angles. The porous high-flow sampler oriented 30 degrees downward showed reasonable agreement with published mannequin wind tunnel studies and humanoid CFD investigations for solid particle aspiration into the mouth, whereas the horizontal orientation resulted in oversampling. Liquid particles were under-aspirated in all cases, however, with 41-84% lower aspiration efficiencies relative to solid particles. A sampler with a single central 15-mm pore at 10 l min(-1) was also investigated and was found to match the porous sampler's aspiration efficiency for solid particles; the single-pore sampler is expected to be more suitable for liquid particle use.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20418278      PMCID: PMC4780251          DOI: 10.1093/annhyg/meq029

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  9 in total

1.  A field comparison of inhalable and thoracic size selective sampling techniques.

Authors:  H W Davies; K Teschke; P A Demers
Journal:  Ann Occup Hyg       Date:  1999-08

2.  An evaluation of total and inhalable samplers for the collection of wood dust in three wood products industries.

Authors:  Martin Harper; Brian S Muller
Journal:  J Environ Monit       Date:  2002-10

3.  Sampling and analysis issues relating to the ACGIH notice of intended change for the beryllium threshold limit value.

Authors:  Michael J Brisson; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2005-12       Impact factor: 2.155

4.  CFD model for a 3-D inhaling mannequin: verification and validation.

Authors:  T Renee Anthony; Michael R Flynn
Journal:  Ann Occup Hyg       Date:  2005-09-12

5.  Laboratory and field testing of sampling methods for inhalable and respirable dust.

Authors:  Markku Linnainmaa; Juha Laitinen; Ari Leskinen; Olli Sippula; Pentti Kalliokoski
Journal:  J Occup Environ Hyg       Date:  2008-01       Impact factor: 2.155

6.  Field comparison of personal samplers for inhalable dust.

Authors:  N P Vaughan; C P Chalmers; R A Botham
Journal:  Ann Occup Hyg       Date:  1990-12

7.  A survey of wind speeds in indoor workplaces.

Authors:  P E Baldwin; A D Maynard
Journal:  Ann Occup Hyg       Date:  1998-07

8.  Field testing of new aerosol sampling method with a porous curved surface as inlet.

Authors:  B C Hauck; S A Grinshpun; A Reponen; T Reponen; K Willeke; R L Bornschein
Journal:  Am Ind Hyg Assoc J       Date:  1997-10

9.  A collaborative European study of personal inhalable aerosol sampler performance.

Authors:  L C Kenny; R Aitken; C Chalmers; J F Fabriès; E Gonzalez-Fernandez; H Kromhout; G Lidén; D Mark; G Riediger; V Prodi
Journal:  Ann Occup Hyg       Date:  1997-04
  9 in total
  5 in total

1.  Solid versus liquid particle sampling efficiency of three personal aerosol samplers when facing the wind.

Authors:  Kirsten A Koehler; T Renee Anthony; Michael Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2011-09-29

2.  Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

Authors:  T Renée Anthony; Darrah Sleeth; John Volckens
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

Review 3.  New Methods for Personal Exposure Monitoring for Airborne Particles.

Authors:  Kirsten A Koehler; Thomas M Peters
Journal:  Curr Environ Health Rep       Date:  2015-12

4.  Three-dimensional computational fluid dynamics modeling of particle uptake by an occupational air sampler using manually-scaled and adaptive grids.

Authors:  Andrea C Landázuri; A Eduardo Sáez; T Renée Anthony
Journal:  J Aerosol Sci       Date:  2016-01-22       Impact factor: 3.433

5.  Airborne Influenza A Is Detected in the Personal Breathing Zone of Swine Veterinarians.

Authors:  Kate M O'Brien; Matthew W Nonnenmann
Journal:  PLoS One       Date:  2016-02-11       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.