Literature DB >> 26513395

Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

T Renée Anthony1, Darrah Sleeth2, John Volckens3.   

Abstract

In the U.S., most industrial hygiene practitioners continue to rely on the closed-face cassette (CFC) to assess worker exposures to hazardous dusts, primarily because ease of use, cost, and familiarity. However, mass concentrations measured with this classic sampler underestimate exposures to larger particles throughout the inhalable particulate mass (IPM) size range (up to aerodynamic diameters of 100 μm). To investigate whether the current 37-mm inlet cap can be redesigned to better meet the IPM sampling criterion, computational fluid dynamics (CFD) models were developed, and particle sampling efficiencies associated with various modifications to the CFC inlet cap were determined. Simulations of fluid flow (standard k-epsilon turbulent model) and particle transport (laminar trajectories, 1-116 μm) were conducted using sampling flow rates of 10 L min(-1) in slow moving air (0.2 m s(-1)) in the facing-the-wind orientation. Combinations of seven inlet shapes and three inlet diameters were evaluated as candidates to replace the current 37-mm inlet cap. For a given inlet geometry, differences in sampler efficiency between inlet diameters averaged less than 1% for particles through 100 μm, but the largest opening was found to increase the efficiency for the 116 μm particles by 14% for the flat inlet cap. A substantial reduction in sampler efficiency was identified for sampler inlets with side walls extending beyond the dimension of the external lip of the current 37-mm CFC. The inlet cap based on the 37-mm CFC dimensions with an expanded 15-mm entry provided the best agreement with facing-the-wind human aspiration efficiency. The sampler efficiency was increased with a flat entry or with a thin central lip adjacent to the new enlarged entry. This work provides a substantial body of sampling efficiency estimates as a function of particle size and inlet geometry for personal aerosol samplers.

Entities:  

Keywords:  Closed-face cassette; computational fluid dynamics; dust sampling; indoor air velocity; inhalable dust; sampler efficiency

Mesh:

Substances:

Year:  2016        PMID: 26513395      PMCID: PMC4706812          DOI: 10.1080/15459624.2015.1091961

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  13 in total

1.  A field evaluation of the impact of transfer efficiency on worker exposure during spray painting.

Authors:  Yu-Mei Tan; Michael R Flynn; Thomas S Buller
Journal:  Ann Occup Hyg       Date:  2002-01

2.  The impact of a change to inhalable occupational exposure limits: strontium chromate exposure in the U.S. Air Force.

Authors:  Gary N Carlton
Journal:  AIHA J (Fairfax, Va)       Date:  2003 May-Jun

3.  A field comparison of the IOM inhalable aerosol sampler and a modified 37-mm cassette.

Authors:  R E Clinkenbeard; E C England; D L Johnson; N A Esmen; T A Hall
Journal:  Appl Occup Environ Hyg       Date:  2002-09

4.  Design and computational fluid dynamics investigation of a personal, high flow inhalable sampler.

Authors:  T Renée Anthony; Andrea C Landázuri; Mike Van Dyke; John Volckens
Journal:  Ann Occup Hyg       Date:  2010-04-23

5.  Contribution of facial feature dimensions and velocity parameters on particle inhalability.

Authors:  T Renée Anthony
Journal:  Ann Occup Hyg       Date:  2010-05-10

6.  Laboratory study of selected personal inhalable aerosol samplers.

Authors:  Peter Görner; Xavier Simon; Richard Wrobel; Edmond Kauffer; Olivier Witschger
Journal:  Ann Occup Hyg       Date:  2010-02-10

7.  A collaborative European study of personal inhalable aerosol sampler performance.

Authors:  L C Kenny; R Aitken; C Chalmers; J F Fabriès; E Gonzalez-Fernandez; H Kromhout; G Lidén; D Mark; G Riediger; V Prodi
Journal:  Ann Occup Hyg       Date:  1997-04

8.  Computational fluid dynamics investigation of human aspiration in low-velocity air: orientation effects on mouth-breathing simulations.

Authors:  T Renée Anthony; Kimberly R Anderson
Journal:  Ann Occup Hyg       Date:  2013-01-12

9.  Computational fluid dynamics investigation of human aspiration in low velocity air: orientation effects on nose-breathing simulations.

Authors:  Kimberly R Anderson; T Renée Anthony
Journal:  Ann Occup Hyg       Date:  2014-03-24

10.  Acid-soluble internal capsules for closed-face cassette elemental sampling and analysis of workplace air.

Authors:  Martin Harper; Kevin Ashley
Journal:  J Occup Environ Hyg       Date:  2013       Impact factor: 2.155

View more
  3 in total

1.  Performance of prototype high-flow inhalable dust sampler in a livestock production facility.

Authors:  T Renée Anthony; Changjie Cai; John Mehaffy; Darrah Sleeth; John Volckens
Journal:  J Occup Environ Hyg       Date:  2017-05       Impact factor: 2.155

2.  Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler.

Authors:  Justin Stewart; Darrah K Sleeth; Rod G Handy; Leon F Pahler; T Renee Anthony; John Volckens
Journal:  J Occup Environ Hyg       Date:  2017-03       Impact factor: 2.155

3.  Estimation of the Human Extrathoracic Deposition Fraction of Inhaled Particles Using a Polyurethane Foam Collection Substrate in an IOM Sampler.

Authors:  Darrah K Sleeth; Susan A Balthaser; Scott Collingwood; Rodney R Larson
Journal:  Int J Environ Res Public Health       Date:  2016-03-07       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.