Literature DB >> 20415324

Changes in ocular response analyzer parameters after LASIK.

Shihao Chen1, Ding Chen, Jianhua Wang, Fan Lu, Qinmei Wang, Jia Qu.   

Abstract

PURPOSE: To investigate changes in Ocular Response Analyzer parameters after myopic LASIK.
METHODS: Thirty myopic patients (60 eyes) undergoing bilateral LASIK were studied prospectively. Corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) measurements were obtained with the Ocular Response Analyzer before and after LASIK. Central corneal thickness and corneal flap thickness were also measured with optical coherence tomography.
RESULTS: Compared with preoperative baseline values, corneal hysteresis, corneal resistance factor, IOPg, IOPcc, and central corneal thickness decreased postoperatively (P<.01). Corneal hysteresis (CH), corneal resistance factor (CRF), IOPg, IOPcc, and central corneal thickness (CCT) increased between 10 days and 3 months (post-hoc, P<.05). (The differences between the preoperative values and those at 3 months postoperatively are denoted by Delta.) The correlation of the ablation depth was stronger for DeltaCRF (r=0.457) than for DeltaCH (r=0.271). DeltaCH was negatively correlated to flap thickness (r=-0.361) and the ratio of flap thickness to preoperative central corneal thickness (r=-0.442) whereas DeltaCRF was not. DeltaCH was positively correlated with DeltaIOPcc, and DeltaCRF was positively correlated with DeltaIOPg. DeltaIOPg was positively correlated with DeltaCCT whereas DeltaIOPcc was not.
CONCLUSIONS: Corneal biomechanical properties measured by corneal hysteresis and corneal resistance factor were decreased at 10 days after LASIK. Minimal recovery (approximately 10% of the changes) was achieved by 3 months. The changes in biomechanical properties may affect IOP measurement. Copyright 2010, SLACK Incorporated.

Entities:  

Mesh:

Year:  2010        PMID: 20415324     DOI: 10.3928/1081597X-20100218-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  14 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer.

Authors:  Ahmed Yassin Hemida; Omar M Said; Asser A E Abdel-Meguid; Mohammed Iqbal; Amani E Badawi
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

3.  Retinal measurements using time domain OCT imaging before and after myopic Lasik.

Authors:  Lei Feng; Feng Lei; Stephen A Burns; Liqin Shao; Yabo Yang
Journal:  Ophthalmic Physiol Opt       Date:  2012-05       Impact factor: 3.117

4.  [Influence of corneal biomechanical properties on myopic regression after laser in situ keratomileusis].

Authors:  D Uthoff; K Hebestedt; G I W Duncker; E Spörl
Journal:  Ophthalmologe       Date:  2013-01       Impact factor: 1.059

5.  Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.

Authors:  Laszlo Modis; Ziad Hassan; Eszter Szalai; Zsuzsanna Flaskó; Andras Berta; Gabor Nemeth
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

6.  Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE).

Authors:  Yang Shen; Xiangjian Su; Xiu Liu; Huamao Miao; Xuejun Fang; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2016-11-18       Impact factor: 2.209

Review 7.  The Effect of Corneal Refractive Surgery on Glaucoma.

Authors:  Vassilios Kozobolis; Aristeidis Konstantinidis; Haris Sideroudi; G Labiris
Journal:  J Ophthalmol       Date:  2017-04-09       Impact factor: 1.909

8.  Dry eye disease after LASIK.

Authors:  L Turu; C Alexandrescu; D Stana; R Tudosescu
Journal:  J Med Life       Date:  2012-03-05

Review 9.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

10.  Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis.

Authors:  Ihab Mohamed Osman; Hany Ahmed Helaly; Moones Abdalla; Mohsen Abou Shousha
Journal:  BMC Ophthalmol       Date:  2016-07-26       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.