Acetabular cartilage thickness: accuracy of three-dimensional reconstructions from multidetector CT arthrograms in a cadaver study.

Bryce C Allen1, Christopher L Peters, Nicholas A T Brown, Andrew E Anderson.   

Abstract

PURPOSE: To prospectively quantify the accuracy of hip cartilage thickness estimated from three-dimensional (3D) surfaces, generated by segmenting multidetector computed tomographic (CT) arthrograms by using direct physical measurements of cartilage thickness as the reference standard.
MATERIALS AND METHODS: Four fresh-frozen cadaver hip joints from two male donors, ages 43 and 46 years, were obtained; institutional review board approval for cadaver research was also obtained. Sixteen holes were drilled perpendicular to the cartilage of four cadaveric acetabula (two specimens). Hip capsules were surgically closed, injected with contrast material, and scanned by using multidetector CT. After scanning, 5.3-mmcores were harvested concentrically at each drill hole and cartilage thickness was measured with a microscope. Cartilage was reconstructed in 3D by using commercial software. Segmentations were repeated by two authors. Reconstructed cartilage thickness was determined by using a published algorithm. Bland-Altman plots and linear regression were used to assess accuracy. Repeatability was quantified by using the coefficient of variation, intraclass correlation coefficient (ICC), repeatability coefficient, and percentage variability.
RESULTS: Cartilage was reconstructed to a bias of -0.13 mm and a repeatability coefficient of + or - 0.46 mm. Regression of the scatterplots indicated a tendency for multidetector CT to overestimate thickness. Intra- and interobserver repeatability were very good. For intraobserver correlation, the coefficient of variation was 14.80%, the ICC was 0.88, the repeatability coefficient was 0.55 mm, and the percentage variability was 11.77%. For interobserver correlation, the coefficient of variation was 13.47%, the ICC was 0.90, the repeatability coefficient was 0.52 mm, and the percentage variability was 11.63%.
CONCLUSION: Assuming that an accuracy of approximately + or - 0.5 mm is sufficient, reconstructions of cartilage geometry from multidetector CT arthrographic data could be used as a preoperative surgical planning tool.

Entities:  

Mesh:

Year:  2010        PMID: 20413764      PMCID: PMC2858813          DOI: 10.1148/radiol.10081876

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  50 in total

1.  Accuracy of CT-based thickness measurement of thin structures: modeling of limited spatial resolution in all three dimensions.

Authors:  Sven Prevrhal; Julia C Fox; John A Shepherd; Harry K Genant
Journal:  Med Phys       Date:  2003-01       Impact factor: 4.071

Review 2.  Special focus session. MR arthrography.

Authors:  Lynne S Steinbach; William E Palmer; Mark E Schweitzer
Journal:  Radiographics       Date:  2002 Sep-Oct       Impact factor: 5.333

3.  Subject-specific finite element model of the pelvis: development, validation and sensitivity studies.

Authors:  Andrew E Anderson; Christopher L Peters; Benjamin D Tuttle; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2005-06       Impact factor: 2.097

Review 4.  Hip MR arthrography and femoroacetabular impingement.

Authors:  Ara Kassarjian
Journal:  Semin Musculoskelet Radiol       Date:  2006-09       Impact factor: 1.777

5.  Improved techniques for measuring in vitro the geometry and pressure distribution in the human acetabulum--I. Ultrasonic measurement of acetabular surfaces, sphericity and cartilage thickness.

Authors:  P D Rushfeldt; R W Mann; W H Harris
Journal:  J Biomech       Date:  1981       Impact factor: 2.712

6.  Interobserver reproducibility of quantitative cartilage measurements: comparison of B-spline snakes and manual segmentation.

Authors:  T Stammberger; F Eckstein; M Michaelis; K H Englmeier; M Reiser
Journal:  Magn Reson Imaging       Date:  1999-09       Impact factor: 2.546

7.  Fat-suppressed 3D spoiled gradient-echo MRI and MDCT arthrography of articular cartilage in patients with hip dysplasia.

Authors:  Takashi Nishii; Hisashi Tanaka; Katsuyuki Nakanishi; Nobuhiko Sugano; Hidenobu Miki; Hideki Yoshikawa
Journal:  AJR Am J Roentgenol       Date:  2005-08       Impact factor: 3.959

8.  Comparative study of the intrinsic mechanical properties of the human acetabular and femoral head cartilage.

Authors:  K A Athanasiou; A Agarwal; F J Dzida
Journal:  J Orthop Res       Date:  1994-05       Impact factor: 3.494

9.  Diffusion and near-equilibrium distribution of MRI and CT contrast agents in articular cartilage.

Authors:  Tuomo S Silvast; Harri T Kokkonen; Jukka S Jurvelin; Thomas M Quinn; Miika T Nieminen; Juha Töyräs
Journal:  Phys Med Biol       Date:  2009-10-28       Impact factor: 3.609

10.  pQCT study on diffusion and equilibrium distribution of iodinated anionic contrast agent in human articular cartilage--associations to matrix composition and integrity.

Authors:  T S Silvast; J S Jurvelin; M J Lammi; J Töyräs
Journal:  Osteoarthritis Cartilage       Date:  2008-07-07       Impact factor: 6.576

View more
  10 in total

1.  Semi-automated landmark-based 3D analysis reveals new morphometric characteristics in the trochlear dysplastic femur.

Authors:  Annemieke Van Haver; Karel De Roo; Matthieu De Beule; Sofie Van Cauter; Emmanuel Audenaert; Tom Claessens; Peter Verdonk
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-19       Impact factor: 4.342

Review 2.  Subject-specific analysis of joint contact mechanics: application to the study of osteoarthritis and surgical planning.

Authors:  Corinne R Henak; Andrew E Anderson; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-02       Impact factor: 2.097

3.  Finite element prediction of cartilage contact stresses in normal human hips.

Authors:  Michael D Harris; Andrew E Anderson; Corinne R Henak; Benjamin J Ellis; Christopher L Peters; Jeffrey A Weiss
Journal:  J Orthop Res       Date:  2011-12-30       Impact factor: 3.494

4.  Accuracy of 3D dual echo steady state (DESS) MR arthrography to quantify acetabular cartilage thickness.

Authors:  Christine L Abraham; Neal K Bangerter; Lance S McGavin; Christopher L Peters; Alex J Drew; Christopher J Hanrahan; Andrew E Anderson
Journal:  J Magn Reson Imaging       Date:  2015-04-06       Impact factor: 4.813

Review 5.  Toward patient-specific articular contact mechanics.

Authors:  Gerard A Ateshian; Corinne R Henak; Jeffrey A Weiss
Journal:  J Biomech       Date:  2014-12-18       Impact factor: 2.712

6.  Validation of watershed-based segmentation of the cartilage surface from sequential CT arthrography scans.

Authors:  Mary E Hall; Marianne S Black; Garry E Gold; Marc E Levenston
Journal:  Quant Imaging Med Surg       Date:  2022-01

7.  Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies.

Authors:  Corinne R Henak; Ashley L Kapron; Andrew E Anderson; Benjamin J Ellis; Steve A Maas; Jeffrey A Weiss
Journal:  Biomech Model Mechanobiol       Date:  2013-06-05

8.  Computed tomography arthrography with traction in the human hip for three-dimensional reconstruction of cartilage and the acetabular labrum.

Authors:  C R Henak; C L Abraham; C L Peters; R K Sanders; J A Weiss; A E Anderson
Journal:  Clin Radiol       Date:  2014-07-25       Impact factor: 2.350

9.  Patients with cam-type femoroacetabular impingement demonstrate increased change in bone-to-bone distance during walking: A dual fluoroscopy study.

Authors:  Cara L Lewis; Keisuke Uemura; Penny R Atkins; Amy L Lenz; Niccolo M Fiorentino; Stephen K Aoki; Andrew E Anderson
Journal:  J Orthop Res       Date:  2022-03-24       Impact factor: 3.102

Review 10.  Advanced Imaging in Osteoarthritis.

Authors:  Qi Li; Keiko Amano; Thomas M Link; C Benjamin Ma
Journal:  Sports Health       Date:  2016-08-10       Impact factor: 3.843

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.