Biotribology of alternative bearing materials for unicompartmental knee arthroplasty.

Thomas M Grupp1, Sandra Utzschneider, Christian Schröder, Jens Schwiesau, Bernhard Fritz, Allan Maas, Wilhelm Blömer, Volkmar Jansson.   

Abstract

The objective of our wear simulator study was to evaluate the suitability of two different carbon fibre-reinforced poly-ether-ether-ketone (CFR-PEEK) materials for fixed bearing unicompartmental knee articulations with low congruency. In vitro wear simulation was performed according to ISO 14243-1:2002 (E) with the clinically introduced Univation F fixed bearing unicompartmental knee design (Aesculap AG, Tuttlingen, Germany) made of UHMWPE/CoCr29Mo6 in a direct comparison to experimental gliding surfaces made of CFR-PEEK pitch and CFR-PEEK PAN. Gliding surfaces of each bearing material (n=6+2) were gamma-irradiated, artificially aged and tested for 5 million cycles with a customized four-station knee wear simulator (EndoLab, Thansau, Germany). Volumetric wear assessment, optical surface characterization and an estimation of particle size and morphology were performed. The volumetric wear rate of the reference PE1-6 was 8.6 +/- 2.17 mm(3) per million cycles, compared to 5.1+/-2.29 mm(3) per million cycles for PITCH1-6 and 5.2 +/- 6.92 mm(3) per million cycles for PAN1-6; these differences were not statistically significant. From our observations, we conclude that CFR-PEEK PAN is obviously unsuitable as a bearing material for fixed bearing knee articulations with low congruency, and CFR-PEEK pitch also cannot be recommended as it remains doubtful wether it reduces wear compared to polyethylene. In the fixed bearing unicompartmental knee arthroplasty examined, application threshold conditions for the biotribiological behaviour of CFR-PEEK bearing materials have been established. Further in vitro wear simulations are necessary to establish knee design criteria in order to take advantage of the biotribiological properties of CFR-PEEK pitch for its beneficial use to patients. 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20371387     DOI: 10.1016/j.actbio.2010.04.003

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  16 in total

1.  [Does increased tibial slope reduce the wear rate of unicompartmental knee prostheses? An in vitro investigation].

Authors:  P Weber; C Schröder; S Utzschneider; F Schmidutz; V Jansson; P E Müller
Journal:  Orthopade       Date:  2012-04       Impact factor: 1.087

2.  Elevated cytokine expression of different PEEK wear particles compared to UHMWPE in vivo.

Authors:  V Lorber; A C Paulus; A Buschmann; B Schmitt; T M Grupp; V Jansson; Sandra Utzschneider
Journal:  J Mater Sci Mater Med       Date:  2013-09-26       Impact factor: 3.896

3.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

4.  The influence of third-body particles on wear rate in unicondylar knee arthroplasty: a wear simulator study with bone and cement debris.

Authors:  Christian Schroeder; Thomas M Grupp; Bernhard Fritz; Christoph Schilling; Yan Chevalier; Sandra Utzschneider; Volkmar Jansson
Journal:  J Mater Sci Mater Med       Date:  2013-02-17       Impact factor: 3.896

5.  The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester.

Authors:  Doruk Baykal; Ryan S Siskey; Richard J Underwood; Adam Briscoe; Steven M Kurtz
Journal:  Clin Orthop Relat Res       Date:  2016-11       Impact factor: 4.176

6.  Increase in the tibial slope reduces wear after medial unicompartmental fixed-bearing arthroplasty of the knee.

Authors:  Patrick Weber; Christian Schröder; Jens Schwiesau; Sandra Utzschneider; Arnd Steinbrück; Matthias F Pietschmann; Volkmar Jansson; Peter E Müller
Journal:  Biomed Res Int       Date:  2015-01-15       Impact factor: 3.411

Review 7.  The Use of Carbon-Fiber-Reinforced (CFR) PEEK Material in Orthopedic Implants: A Systematic Review.

Authors:  Chuan Silvia Li; Christopher Vannabouathong; Sheila Sprague; Mohit Bhandari
Journal:  Clin Med Insights Arthritis Musculoskelet Disord       Date:  2015-02-23

Review 8.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

9.  Histopathological Analysis of PEEK Wear Particle Effects on the Synovial Tissue of Patients.

Authors:  A C Paulus; S Haßelt; V Jansson; A Giurea; H Neuhaus; T M Grupp; S Utzschneider
Journal:  Biomed Res Int       Date:  2016-08-16       Impact factor: 3.411

10.  Early results of a new rotating hinge knee implant.

Authors:  Alexander Giurea; Hans-Joachim Neuhaus; Rolf Miehlke; Reinhard Schuh; Richard Lass; Bernd Kubista; Reinhard Windhager
Journal:  Biomed Res Int       Date:  2014-06-25       Impact factor: 3.411