Literature DB >> 20308494

Effect of padding duration on radiation dose and image interpretation in prospectively ECG-triggered coronary CT angiography.

Troy M Labounty1, Jonathon Leipsic, James K Min, Brett Heilbron, G B John Mancini, Fay Y Lin, James P Earls.   

Abstract

OBJECTIVE: Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose. SUBJECTS AND METHODS: We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose.
RESULTS: The mean patient age was 56 +/- 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001).
CONCLUSION: In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20308494     DOI: 10.2214/AJR.09.3371

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  19 in total

Review 1.  Established and emerging dose reduction methods in cardiac computed tomography.

Authors:  Gary R Small; Mustapha Kazmi; Robert A Dekemp; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

Review 2.  Important advances in technology and unique applications to cardiovascular computed tomography.

Authors:  Kongkiat Chaikriangkrai; Su Yeon Choi; Faisal Nabi; Su Min Chang
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

Review 3.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

Review 4.  Recent advances in cardiac computed tomography dose reduction strategies: a review of scientific evidence and technical developments.

Authors:  Sandeep S Hedgire; Vinit Baliyan; Brian B Ghoshhajra; Mannudeep K Kalra
Journal:  J Med Imaging (Bellingham)       Date:  2017-08-24

5.  Prospectively ECG-triggered high-pitch spiral acquisition for cardiac CT angiography in routine clinical practice: initial results.

Authors:  Patric Kröpil; Carlos A Rojas; Brian Ghoshhajra; Rotem S Lanzman; Falk R Miese; Axel Scherer; Mannudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2012-05       Impact factor: 3.000

Review 6.  Radiation exposure from imaging tests: is there an increased cancer risk?

Authors:  Patricia K Nguyen; Joseph C Wu
Journal:  Expert Rev Cardiovasc Ther       Date:  2011-02

Review 7.  State-of-the-art in CT hardware and scan modes for cardiovascular CT.

Authors:  Sandra Halliburton; Armin Arbab-Zadeh; Damini Dey; Andrew J Einstein; Ralph Gentry; Richard T George; Thomas Gerber; Mahadevappa Mahesh; Wm Guy Weigold
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-07

8.  Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

Authors:  Haruhiko Machida; Xiao-Zhu Lin; Rika Fukui; Yun Shen; Shigeru Suzuki; Isao Tanaka; Takuya Ishikawa; Etsuko Tate; Eiko Ueno
Journal:  Jpn J Radiol       Date:  2014-12-12       Impact factor: 2.374

Review 9.  Coronary CT angiography with prospective ECG-triggering: an effective alternative to invasive coronary angiography.

Authors:  Zhonghua Sun
Journal:  Cardiovasc Diagn Ther       Date:  2012-03

10.  Defining the mid-diastolic imaging period for cardiac CT - lessons from tissue Doppler echocardiography.

Authors:  James M Otton; Justin Phan; Michael Feneley; Chung-yao Yu; Neville Sammel; Jane McCrohon
Journal:  BMC Med Imaging       Date:  2013-02-01       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.