Literature DB >> 20195597

Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips.

Thomas Baad-Hansen1, Stig Storgaard Jakobsen, Kjeld Soballe.   

Abstract

There has been renewed interest for metal-on-metal hip resurfacing due to improved design and manufacturing of implants, better materials, and enhanced implant fixation. In contrast to conventional total hip replacements, only a few clinical hip resurfacing trials using radiostereometry (RSA) have been reported, and solely for the Birmingham hip resurfacing arthroplasty. The purpose of this RSA trial was to describe the migration pattern of a new hip resurfacing system (ReCap) within the first two years after primary surgery. Twenty-six patients underwent total hip replacement. The patients were followed-up for up to 24 months and were evaluated with the use of radiostereometric measurements. The prosthesis showed mean translations and rotation close to zero. Maximum translation was seen along the transverse axis in the medial direction (0.13 mm). No statistically significant translation or rotation was seen at two-years follow-up, (t-test, p <0.05, translation or rotation).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20195597      PMCID: PMC3066327          DOI: 10.1007/s00264-010-0976-x

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  Orientation of the femoral component in surface arthroplasty of the hip. A biomechanical and clinical analysis.

Authors:  Paul E Beaulé; Jessica L Lee; Michel J Le Duff; Harlan C Amstutz; Edward Ebramzadeh
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

Review 2.  Roentgen stereophotogrammetric analysis of prosthetic fixation in the hip and knee joint.

Authors:  L Ryd
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

Review 3.  Roentgen stereophotogrammetry. Review of orthopedic applications.

Authors:  J Kärrholm
Journal:  Acta Orthop Scand       Date:  1989-08

4.  Stability of the Birmingham hip resurfacing arthroplasty at two years. A radiostereophotogrammetric analysis study.

Authors:  R Itayem; A Arndt; L Nistor; D McMinn; A Lundberg
Journal:  J Bone Joint Surg Br       Date:  2005-02

5.  EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip.

Authors:  P E Beaulé; M Krismer; P Mayrhofer; S Wanner; M Le Duff; M Mattesich; B Stoeckl; H C Amstutz; R Biedermann
Journal:  J Bone Joint Surg Br       Date:  2005-05

6.  A finite element analysis of factors influencing total hip dislocation.

Authors:  C F Scifert; T D Brown; D R Pedersen; J J Callaghan
Journal:  Clin Orthop Relat Res       Date:  1998-10       Impact factor: 4.176

7.  Guidelines for standardization of radiostereometry (RSA) of implants.

Authors:  Edward R Valstar; Richie Gill; Leif Ryd; Gunnar Flivik; Niclas Börlin; Johan Kärrholm
Journal:  Acta Orthop       Date:  2005-08       Impact factor: 3.717

8.  Internal fixation after subtrochanteric femoral fracture after hip resurfacing arthroplasty.

Authors:  Paul Whittingham-Jones; Godfrey Charnley; Jason Francis; Satyanarayana Annapureddy
Journal:  J Arthroplasty       Date:  2008-12-04       Impact factor: 4.757

9.  Fracture of the neck of the femur after surface arthroplasty of the hip.

Authors:  Harlan C Amstutz; Pat A Campbell; Michel J Le Duff
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

10.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study.

Authors:  Harlan C Amstutz; Paul E Beaulé; Frederick J Dorey; Michel J Le Duff; Pat A Campbell; Thomas A Gruen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

View more
  6 in total

1.  Analysis of migration of the Nanos® short-stem hip implant within two years after surgery.

Authors:  Stefan Budde; Frank Seehaus; Michael Schwarze; Christof Hurschler; Thilo Floerkemeier; Henning Windhagen; Yvonne Noll; Max Ettinger; Fritz Thorey
Journal:  Int Orthop       Date:  2015-09-25       Impact factor: 3.075

Review 2.  Metal-on-Metal Bearing: Is This the End of the Line? We Do Not Think So.

Authors:  Henri Migaud; Sophie Putman; Antoine Combes; Charles Berton; Donatien Bocquet; Laurent Vasseur; Julien Girard
Journal:  HSS J       Date:  2012-09-11

3.  Hip resurfacing in a district general hospital: 6-year clinical results using the ReCap hip resurfacing system.

Authors:  Walter van der Weegen; Henk J Hoekstra; Thea Sijbesma; Shennah Austen; Rudolf W Poolman
Journal:  BMC Musculoskelet Disord       Date:  2012-12-13       Impact factor: 2.362

Review 4.  Adherence of hip and knee arthroplasty studies to RSA standardization guidelines. A systematic review.

Authors:  Rami Madanat; Tatu J Mäkinen; Hannu T Aro; Charles Bragdon; Henrik Malchau
Journal:  Acta Orthop       Date:  2014-06-23       Impact factor: 3.717

5.  No association between serum metal ions and implant fixation in large-head metal-on-metal total hip arthroplasty.

Authors:  Mette Holm Hjorth; Kjeld Søballe; Stig Storgaard Jakobsen; Nina Dyrberg Lorenzen; Inger Mechlenburg; Maiken Stilling
Journal:  Acta Orthop       Date:  2014-05-21       Impact factor: 3.717

6.  Metal release and metal allergy after total hip replacement with resurfacing versus conventional hybrid prosthesis.

Authors:  Klas Gustafson; Stig S Jakobsen; Nina D Lorenzen; Jacob P Thyssen; Jeanne D Johansen; Charlotte M Bonefeld; Maiken Stilling; Thomas Baad-Hansen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2014-06-16       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.