Literature DB >> 15855382

EBRA-FCA for measurement of migration of the femoral component in surface arthroplasty of the hip.

P E Beaulé1, M Krismer, P Mayrhofer, S Wanner, M Le Duff, M Mattesich, B Stoeckl, H C Amstutz, R Biedermann.   

Abstract

Studies on the migration of an implant may be the only way of monitoring the early performance of metal-on-metal prostheses. The Ein Bild Roentgen Analyse--femoral component analysis (EBRA-FCA) method was adapted to measure migration of the femoral component in a metal-on-metal surface arthroplasty of the hip using standard antero-posterior radiographs. In order to determine the accuracy and precision of this method a prosthesis was implanted into cadaver bones. Eleven series of radiographs were used to perform a zero-migration study. After adjustment of the femoral component to simulate migration of 3 mm the radiographs were repeated. All were measured independently by three different observers. The accuracy of the method was found to be +/- 1.6 mm for the x-direction and +/- 2 mm for the y-direction (95% percentile). The method was validated using 28 hips with a minimum follow-up of 3.5 years after arthroplasty. Seventeen were sound, but 11 had failed because of loosening of the femoral component. The normal (control) group had a different pattern of migration compared with that of the loose group. At 29.2 months, the control group showed a mean migration of 1.62 mm and 1.05 mm compared with 4.39 mm and 4.05 mm in the failed group, for the centre of the head and the tip of the stem, respectively (p = 0.001). In the failed group, the mean time to migration greater than 2 mm was earlier than the onset of clinical symptoms or radiological evidence of failure, 19.1 versus 32.2 months (p = 0.001) and 24.8 months (p = 0.012), respectively. EBRA-FCA is a reliable and valid tool for measuring migration of the femoral component after surface arthroplasty and can be used to predict early failure of the implant. It may be of value in determining the long-term performance of surface arthroplasty.

Entities:  

Mesh:

Year:  2005        PMID: 15855382     DOI: 10.1302/0301-620X.87B5.15377

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

1.  2008 Otto Aufranc Award: component design and technique affect cement penetration in hip resurfacing.

Authors:  Paul E Beaulé; Wadih Y Matar; Philippe Poitras; Kevin Smit; Olivier May
Journal:  Clin Orthop Relat Res       Date:  2008-10-16       Impact factor: 4.176

2.  Two-year migration results of the ReCap hip resurfacing system-a radiostereometric follow-up study of 23 hips.

Authors:  Thomas Baad-Hansen; Stig Storgaard Jakobsen; Kjeld Soballe
Journal:  Int Orthop       Date:  2010-02-27       Impact factor: 3.075

3.  Migration pattern of cemented Exeter short stem in Dorr type A femurs. A prospective radiostereometry study with 2-year follow-up.

Authors:  Tobias Dahl Vind; Peter Bo Jørgensen; Dovydas Vainorius; Stig Storgaard Jakobsen; Kjeld Søballe; Maiken Stilling
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-03       Impact factor: 3.067

4.  Comparison of Femoral Bone Mineral Density Changes around 3 Common Designs of Cementless Stems after Total Hip Arthroplasty-A Retrospective Cohort Study.

Authors:  Yuan Liu; Wen-Xing Wei; Yi Zeng; Jun Ma; Jing Yang; Bin Shen
Journal:  Orthop Surg       Date:  2022-04-25       Impact factor: 2.279

5.  Influence of head size on the development of metallic wear and on the characteristics of carbon layers in metal-on-metal hip joints.

Authors:  Volker Braunstein; Christoph M Sprecher; Markus A Wimmer; Stefan Milz; Georg Taeger
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

6.  Migration analysis of a metaphyseal anchored short-stem hip prosthesis.

Authors:  Florian Schmidutz; Thomas Graf; Farhad Mazoochian; Andreas Fottner; Andrea Bauer-Melnyk; Volkmar Jansson
Journal:  Acta Orthop       Date:  2012-08       Impact factor: 3.717

7.  Development and validation of an automated and marker-free CT-based spatial analysis method (CTSA) for assessment of femoral hip implant migration: In vitro accuracy and precision comparable to that of radiostereometric analysis (RSA).

Authors:  Thierry Scheerlinck; Mathias Polfliet; Rudi Deklerck; Gert Van Gompel; Nico Buls; Jef Vandemeulebroucke
Journal:  Acta Orthop       Date:  2015-12-03       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.