Literature DB >> 20194322

Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up.

George E Petsatodis1, Pericles P Papadopoulos, Kyriakos A Papavasiliou, Ippokratis G Hatzokos, Filon G Agathangelidis, Anastasios G Christodoulou.   

Abstract

BACKGROUND: The biological problems related to wear debris after total hip arthroplasty have stimulated renewed interest in alternatives to metal-on-polyethylene bearing surfaces.
METHODS: We retrospectively evaluated the clinical and radiographic results of 100 patients who had undergone a total of 109 primary total hip arthroplasties with a cementless alumina ceramic-on-ceramic prosthesis between January 1985 and December 1989. The mean age of the patients at the time of the index arthroplasty was forty-six years. Clinical evaluation was performed with use of the Charnley modification of the Merle d'Aubigné-Postel scale. Seventy-eight patients who had had a total of eighty-five arthroplasties were available for follow-up evaluation at an average of 20.8 years. The patients' average age at the time of the latest follow-up was 66.8 years.
RESULTS: Six hips (six acetabular cups and one femoral stem) in six patients underwent revision. Aseptic loosening of the cup combined with focal osteolysis was the cause of all six revisions. In one patient, the stem was also revised because of aseptic loosening. At the time of final follow-up, the result was excellent (according to the Merle d'Aubigné-Postel scale) in 68% of the hips, good in 19%, fair in 9%, and poor in 4%. The mean Merle d'Aubigné-Postel score improved from 7.9 points preoperatively to 16.9 points postoperatively (p < 0.001). The cumulative rate of survival of the prostheses was 84.4% at 20.8 years.
CONCLUSIONS: The results of these cementless ceramic-on-ceramic total hip arthroplasties continued to be satisfactory at a minimum of twenty years postoperatively. The improved design of contemporary prostheses and the new generation of ceramic-on-ceramic bearing surfaces may lead to even better long-term results.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20194322     DOI: 10.2106/JBJS.H.01829

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  21 in total

1.  Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.

Authors:  Manny Porat; Javad Parvizi; Peter F Sharkey; Keith R Berend; Adolph V Lombardi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Bone mineral density of the proximal femur recovers after metal-on-metal hip resurfacing.

Authors:  Matteo Cadossi; Antonio Moroni; Matteo Romagnoli; Eugenio Chiarello; Cesare Faldini; Sandro Giannini
Journal:  Clin Cases Miner Bone Metab       Date:  2010-05

Review 3.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

4.  [MUW researcher of the month].

Authors:  Richard Lass
Journal:  Wien Klin Wochenschr       Date:  2015-11       Impact factor: 1.704

5.  High rate of ceramic sandwich liner fracture.

Authors:  Ronny Lopes; Jean M Philippeau; Norbert Passuti; François Gouin
Journal:  Clin Orthop Relat Res       Date:  2012-03-02       Impact factor: 4.176

6.  Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

Authors:  André Ferreira; Thierry Aslanian; Thibaud Dalin; Jean Picaud
Journal:  Int Orthop       Date:  2016-08-20       Impact factor: 3.075

Review 7.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

8.  Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings.

Authors:  T Bouras; T Repantis; P Fennema; P Korovessis
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-12

9.  Mid-term results of Bernese periacetabular osteotomy for developmental dysplasia of hip in middle aged patients.

Authors:  Junfeng Zhu; Xiaodong Chen; Yiming Cui; Chao Shen; Guiquan Cai
Journal:  Int Orthop       Date:  2013-02-05       Impact factor: 3.075

10.  High failure rate of a new pressfit cup in mid-term follow-up.

Authors:  Steffen Brodt; Georg Matziolis; Christoph Windisch; Andreas Gosse; Matthias Spalteholz; Ralf Herbert Gahr
Journal:  Int Orthop       Date:  2015-07-08       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.