PURPOSE: To compare target dose distribution, comformality, normal tissue avoidance, and irradiated body volume (IBV) in 3DCRT using classic anatomical landmarks (c3DCRT), 3DCRT fitting the PTV (f3DCRT), and intensity-modulated radiation therapy (IMRT) in patients with locally advanced rectal cancer (LARC).Entities:
Mesh:
Year: 2010 PMID: 20187944 PMCID: PMC2845593 DOI: 10.1186/1748-717X-5-17
Source DB: PubMed Journal: Radiat Oncol ISSN: 1748-717X Impact factor: 3.481
Dosimetric summary of target volumes
| D95 (Gy) | Dmin (Gy) | Dmax(Gy) | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| c3DCRT | f3DCRT | IMRT | c3DCRT | f3DCRT | IMRT | c3DCRT | f3DCRT | IMRT | ||
| GTV | mean | 47.5 | 47.5 | 46.9 | 46.7 | 46.6 | 45.1 | 50.2 | 50.3 | 51.6 |
| SD | 0.6 | 0.7 | 2.3 | 0.4 | 0.6 | 2.0 | 1.0 | 1.0 | 2.7 | |
| Ref | Ref | |||||||||
| PTV | mean | 47.1 | 46.9 | 45.7 | 39.5 | 42.2 | 39.2 | 51.1 | 51.2 | 54.0 |
| SD | 0.5 | 0.5 | 0.8 | 4.2 | 1.2 | 1.7 | 0.6 | 0.5 | 2.6 | |
| Ref | Ref | |||||||||
c3DCRT: classic tridimensional conformal radiotherapy;
f3DCRT: fitting tridimensional conformal radiotherapy,
IMRT: intensity modulated radiation therapy;
D95: minimal dose to 95% of the volume;
GTV: gross tumor volume;
PTV: planning target volume;
SD: Standard deviation;
p1: c3DCRT vs IMRT;
p2: f3DCRT vs IMRT;
Ref:Referencevalue
Figure 1Target dose volume histograms comparison. DVH: dose-volume histogram. GTV: gross tumor volume. CTV: clinical target volume. PTV: planning target volume. c3DCRT: conventional tridimensional conformal radiotherapy (blue line). f3DCRT: modificated tridimensional conformal radiotherapy (pink line). IMRT: intensity modulated radiation therapy (green line).
Homogeneity and Conformity Index of Target Volumes
| HI | CI | ||||||
|---|---|---|---|---|---|---|---|
| c3DCRT | f3DCRT | IMRT | c3DCRT | f3DCRT | IMRT | ||
| GTV | mean | 0.8 | 0.8 | 1.1 | |||
| SD | 0.2 | 0.2 | 0.3 | ||||
| Ref | |||||||
| PTV | mean | 1.1 | 1.1 | 1.6 | 0.5 | 0.6 | 0.8 |
| SD | 0.1 | 0.2 | 0.3 | 0.1 | 0.1 | 0.1 | |
| Ref | Ref | ||||||
HI: homogeneity index;
CI: Conformity index
c3DCRT: classic tridimensional conformal radiotherapy;
f3DCRT: fitting tridimensional conformal radiotherapy,
IMRT: intensity modulated radiation therapy;
GTV: gross tumor volume;
CTV: clinical target volume;
PTV: planning target volume;
pc3DCRT vs IMRT;
pf3DCRT vs IMRT;
Ref:Referencevalue
Figure 2Isodose distribution in a patient with a uT3N+ medial rectal cancer. planned with c3DCRT (A and D), f3DCRT (B and E) and IMRT (C and F). The. orange line represents the 95% isodose. c3DCRT: conventional tridimensional conformal radiotherapy. f3DCRT: modificated tridimensional conformal radiotherapy. IMRT: intensity modulated radiation therapy.
OARV Parameters
| D5 (Gy) | V40 (cc) | ||||||
|---|---|---|---|---|---|---|---|
| c3DCRT | f3DCRT | IMRT | c3DCRT | f3DCRT | IMRT | ||
| BLADDER | mean | 48.8 | 48.4 | 46.2 | 94.7 | 60.9 | 34.4 |
| SD | 0.5 | 0.5 | 4.1 | 66.2 | 26.5 | 24.9 | |
| Ref | Ref | ||||||
| SMALL BOWEL | mean | 49.2 | 49.0 | 46.2 | 178.3 | 140.3 | 68.9 |
| SD | 0.5 | 0.8 | 4.1 | 136.6 | 120.7 | 63.5 | |
| Ref | Ref | ||||||
| RECTUM | mean | 50.7 | 50.8 | 50.6 | 162.3 | 157.7 | |
| SD | 0.6 | 0.6 | 2.3 | 55.7 | 56.5 | 54.8 | |
| Ref | Ref | ||||||
OARV: Organs at risk volume
c3DCRT: classic tridimensional conformal radiotherapy;
f3DCRT: fitting tridimensional conformal radiotherapy,
IMRT: intensity modulated radiation therapy;
D5: minimal dose received by 5% of the OARV;
V40: volume receiving ≥ 40 Gy
GTV: gross tumor volume;
PTV: planning target volume;
pc3DCRT vs IMRT;
pf3DCRT vs IMRT;
Ref: Reference value
Figure 3Organ at risk dose volume histograms comparisson. c3DCRT: conventional tridimensional conformal radiotherapy (blue line). f3DCRT: modificated tridimensional conformal radiotherapy (pink line). IMRT: intensity modulated radiation therapy (green line).
Irradiated Body Volume
| c3DCRT | f3DCRT | IMRT | |
|---|---|---|---|
| V5 (cc) | 11484 | 10302 | 12164 |
| Ref | |||
| V10 (cc) | 9419 | 8416 | 9232 |
| Ref | |||
| V20 (cc) | 7781 | 6881 | 5764 |
| Ref |
c3DCRT: classic tridimensional conformal radiotherapy;
f3DCRT: fitting tridimensional conformal radiotherapy,
IMRT: intensity modulated radiation therapy;
V5: body volume receiving ≥ 5 Gy;
V10: body volume receiving ≥ 10 Gy;
V20: body volume receiving ≥ 20 Gy;
pc3DCRT vs IMRT;
pf3DCRT vs IMRT;
Ref: Reference value
Figure 4Irradiated body volume dose-volume histograms. c3DCRT: conventional tridimensional conformal radiotherapy (blue line). f3DCRT: modificated tridimensional conformal radiotherapy (pink line). IMRT: intensity modulated radiation therapy (green line).