Literature DB >> 20178900

Trade-offs in data acquisition and processing parameters for backscatter and scatterer size estimations.

Wu Liu1, James A Zagzebski.   

Abstract

By analyzing backscattered echo signal power spectra and thereby obtaining backscatter coefficient vs. frequency data, the size of subresolution scatterers contributing to echo signals can be estimated. Here we investigate trade-offs in data acquisition and processing parameters for reference phantom-based backscatter and scatterer size estimations. RF echo data from a tissue-mimicking test phantom were acquired using a clinical scanner equipped with linear array transducers. One array has a nominal frequency bandwidth of 5 to 13 MHz and the other 4 to 9 MHz. Comparison of spectral estimation methods showed that the Welch method provided spectra yielding more accurate and precise backscatter coefficient and scatterer size estimations than spectra computed by applying rectangular, Hanning, or Hamming windows and much reduced computational load than if using the multitaper method. For small echo signal data block sizes, moderate improvements in scatterer size estimations were obtained using a multitaper method, but this significantly increases the computational burden. It is critical to average power spectra from lateral A-lines for the improvement of scatterer size estimation. Averaging approximately 10 independent A-lines laterally with an axial window length 10 times the center frequency wavelength optimized trade-offs between spatial resolution and the variance of scatterer size estimates. Applying the concept of a time-bandwidth product, this suggests using analysis blocks that contain at least 30 independent samples of the echo signal. The estimation accuracy and precision depend on the ka range where k is the wave number and a is the effective scatterer size. This introduces a region-of-interest depth dependency to the accuracy and precision because of preferential attenuation of higher frequency sound waves in tissuelike media. With the 5 to 13 MHz, transducer ka ranged from 0.5 to 1.6 for scatterers in the test phantom, which is a favorable range, and the accuracy and precision of scatterer size estimations were both within approximately 5% using optimal analysis block dimensions. When the 4- to 9-MHz transducer was used, the ka value ranged from 0.3 to 0.8 to 1.1 for the experimental conditions, and the accuracy and precision were found to be approximately 10% and 10% to 25%, respectively. Although the experiments were done with 2 specific models of transducers on the test phantom, the results can be generalized to similar clinical arrays available from a variety of manufacturers and/or for different size of scatterers with similar ka range.

Entities:  

Mesh:

Year:  2010        PMID: 20178900      PMCID: PMC2853955          DOI: 10.1109/TUFFC.2010.1414

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  32 in total

1.  A test phantom for estimating changes in the effective frequency of an ultrasonic scanner.

Authors:  Thaddeus Wilson; James Zagzebski; Yadong Li
Journal:  J Ultrasound Med       Date:  2002-09       Impact factor: 2.153

2.  Defining optimal axial and lateral resolution for estimating scatterer properties from volumes using ultrasound backscatter.

Authors:  Michael L Oelze; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2004-06       Impact factor: 1.840

3.  Statistical uncertainty in ultrasonic backscatter and attenuation coefficients determined with a reference phantom.

Authors:  L X Yao; J A Zagzebski; E L Madsen
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

4.  Improved scatterer property estimates from ultrasound backscatter for small gate lengths using a gate-edge correction factor.

Authors:  Michael L Oelze; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2004-11       Impact factor: 1.840

5.  Impact of local attenuation approximations when estimating correlation length from backscattered ultrasound echoes.

Authors:  Timothy A Bigelow; William D O'Brien
Journal:  J Acoust Soc Am       Date:  2006-07       Impact factor: 1.840

6.  Parametric ultrasound imaging from backscatter coefficient measurements: image formation and interpretation.

Authors:  M F Insana; T J Hall
Journal:  Ultrason Imaging       Date:  1990-10       Impact factor: 1.578

7.  Attenuation estimation using spectral cross-correlation.

Authors:  Hyungsuk Kim; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-03       Impact factor: 2.725

8.  Spectral and scatterer-size correlation during angular compounding: simulations and experimental studies.

Authors:  W Liu; J A Zagzebski; T Varghese; A L Gerig; T J Hall
Journal:  Ultrason Imaging       Date:  2006-10       Impact factor: 1.578

9.  Estimating the spatial autocorrelation function for ultrasound scatterers in isotropic media.

Authors:  J F Chen; J A Zagzebski; F Dong; E L Madsen
Journal:  Med Phys       Date:  1998-05       Impact factor: 4.071

10.  Liver tumors: utility of characterization at dual-frequency US.

Authors:  G Sommer; E W Olcott; L Tai
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

View more
  10 in total

1.  Improving the statistics of quantitative ultrasound techniques with deformation compounding: an experimental study.

Authors:  Maria-Teresa Herd; Timothy J Hall; Jingfeng Jiang; James A Zagzebski
Journal:  Ultrasound Med Biol       Date:  2011-10-26       Impact factor: 2.998

2.  A Quantitative Ultrasound-Based Multi-Parameter Classifier for Breast Masses.

Authors:  Haidy G Nasief; Ivan M Rosado-Mendez; James A Zagzebski; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2019-04-26       Impact factor: 2.998

3.  Task-oriented comparison of power spectral density estimation methods for quantifying acoustic attenuation in diagnostic ultrasound using a reference phantom method.

Authors:  Ivan M Rosado-Mendez; Kibo Nam; Timothy J Hall; James A Zagzebski
Journal:  Ultrason Imaging       Date:  2013-07       Impact factor: 1.578

4.  Quantitative ultrasound estimates from populations of scatterers with continuous size distributions: effects of the size estimator algorithm.

Authors:  Roberto Lavarello; Michael Oelze
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

5.  Mean scatterer spacing estimation using multi-taper coherence.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-06       Impact factor: 2.725

6.  Estimating cell concentration in three-dimensional engineered tissues using high frequency quantitative ultrasound.

Authors:  Karla P Mercado; María Helguera; Denise C Hocking; Diane Dalecki
Journal:  Ann Biomed Eng       Date:  2014-03-14       Impact factor: 3.934

Review 7.  Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound.

Authors:  Michael L Oelze; Jonathan Mamou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-01-08       Impact factor: 2.725

8.  Analysis of Coherent and Diffuse Scattering Using a Reference Phantom.

Authors:  Ivan M Rosado-Mendez; Lindsey C Drehfal; James A Zagzebski; Timothy J Hall
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-03-25       Impact factor: 2.725

9.  Quantitative Ultrasound Detects Smooth Muscle Activity at the Cervical Internal Os in Vitro.

Authors:  Andrew P Santoso; Joy Y Vink; George Gallos; Helen Feltovich; Timothy J Hall
Journal:  Ultrasound Med Biol       Date:  2019-10-24       Impact factor: 2.998

10.  Toward 3-D Echocardiographic Determination of Regional Myofiber Structure.

Authors:  Michelle L Milne; Gautam K Singh; James G Miller; Kirk D Wallace; Mark R Holland
Journal:  Ultrasound Med Biol       Date:  2015-11-14       Impact factor: 2.998

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.