Literature DB >> 20159917

Consistency of methods for analysing location-specific data.

F Zanca1, D P Chakraborty, G Marchal, H Bosmans.   

Abstract

Although the receiver operating characteristic (ROC) method is the acknowledged gold-standard for imaging system assessment, it ignores localisation information and differentiation between multiple abnormalities per case. As the free-response ROC (FROC) method uses localisation information and more closely resembles the clinical reporting process, it is being increasingly used. A number of methods have been proposed to analyse the data that result from an FROC study: jackknife alternative FROC (JAFROC) and a variant termed JAFROC1, initial detection and candidate analysis (IDCA) and ROC analysis via the reduction of the multiple ratings on a case to a single rating. The focus of this paper was to compare JAFROC1, IDCA and the ROC analysis methods using a clinical FROC human data set. All methods agreed on the ordering of the modalities and all yielded statistically significant differences of the figures-of-merit, i.e. p < 0.05. Both IDCA and JAFROC1 yielded much smaller p-values than ROC. The results are consistent with a recent simulation-based validation study comparing these and other methods. In conclusion, IDCA or JAFROC1 analysis of FROC human data may be superior at detecting modality differences than ROC analysis.

Entities:  

Mesh:

Year:  2010        PMID: 20159917      PMCID: PMC2868070          DOI: 10.1093/rpd/ncq030

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  17 in total

1.  Statistical power in observer-performance studies: comparison of the receiver operating characteristic and free-response methods in tasks involving localization.

Authors:  Dev Chakraborty
Journal:  Acad Radiol       Date:  2002-02       Impact factor: 3.173

2.  Observer studies involving detection and localization: modeling, analysis, and validation.

Authors:  Dev P Chakraborty; Kevin S Berbaum
Journal:  Med Phys       Date:  2004-08       Impact factor: 4.071

3.  A search model and figure of merit for observer data acquired according to the free-response paradigm.

Authors:  D P Chakraborty
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

4.  Spatial localization accuracy of radiologists in free-response studies: Inferring perceptual FROC curves from mark-rating data.

Authors:  Dev Chakraborty; Hong-Jun Yoon; Claudia Mello-Thoms
Journal:  Acad Radiol       Date:  2007-01       Impact factor: 3.173

Review 5.  Analysis of location specific observer performance data: validated extensions of the jackknife free-response (JAFROC) method.

Authors:  Dev P Chakraborty
Journal:  Acad Radiol       Date:  2006-10       Impact factor: 3.173

Review 6.  Receiver operating characteristic analysis: a tool for the quantitative evaluation of observer performance and imaging systems.

Authors:  Charles E Metz
Journal:  J Am Coll Radiol       Date:  2006-06       Impact factor: 5.532

7.  Proper receiver operating characteristic analysis: the bigamma model.

Authors:  D D Dorfman; K S Berbaum; C E Metz; R V Lenth; J A Hanley; H Abu Dagga
Journal:  Acad Radiol       Date:  1997-02       Impact factor: 3.173

8.  Maximum likelihood analysis of free-response receiver operating characteristic (FROC) data.

Authors:  D P Chakraborty
Journal:  Med Phys       Date:  1989 Jul-Aug       Impact factor: 4.071

9.  Evaluating computer-aided detection algorithms.

Authors:  Hong Jun Yoon; Bin Zheng; Berkman Sahiner; Dev P Chakraborty
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

10.  Validation and statistical power comparison of methods for analyzing free-response observer performance studies.

Authors:  Dev P Chakraborty
Journal:  Acad Radiol       Date:  2008-12       Impact factor: 3.173

View more
  1 in total

1.  Evaluating imaging and computer-aided detection and diagnosis devices at the FDA.

Authors:  Brandon D Gallas; Heang-Ping Chan; Carl J D'Orsi; Lori E Dodd; Maryellen L Giger; David Gur; Elizabeth A Krupinski; Charles E Metz; Kyle J Myers; Nancy A Obuchowski; Berkman Sahiner; Alicia Y Toledano; Margarita L Zuley
Journal:  Acad Radiol       Date:  2012-02-03       Impact factor: 3.173

  1 in total