Literature DB >> 20157226

Acceleration of the direct reconstruction of linear parametric images using nested algorithms.

Guobao Wang1, Jinyi Qi.   

Abstract

Parametric imaging using dynamic positron emission tomography (PET) provides important information for biological research and clinical diagnosis. Indirect and direct methods have been developed for reconstructing linear parametric images from dynamic PET data. Indirect methods are relatively simple and easy to implement because the image reconstruction and kinetic modeling are performed in two separate steps. Direct methods estimate parametric images directly from raw PET data and are statistically more efficient. However, the convergence rate of direct algorithms can be slow due to the coupling between the reconstruction and kinetic modeling. Here we present two fast gradient-type algorithms for direct reconstruction of linear parametric images. The new algorithms decouple the reconstruction and linear parametric modeling at each iteration by employing the principle of optimization transfer. Convergence speed is accelerated by running more sub-iterations of linear parametric estimation because the computation cost of the linear parametric modeling is much less than that of the image reconstruction. Computer simulation studies demonstrated that the new algorithms converge much faster than the traditional expectation maximization (EM) and the preconditioned conjugate gradient algorithms for dynamic PET.

Entities:  

Mesh:

Year:  2010        PMID: 20157226      PMCID: PMC2952886          DOI: 10.1088/0031-9155/55/5/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  Direct least-squares estimation of spatiotemporal distributions from dynamic SPECT projections using a spatial segmentation and temporal B-splines.

Authors:  B W Reutter; G T Gullberg; R H Huesman
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

2.  Spatiotemporal reconstruction of list-mode PET data.

Authors:  Thomas E Nichols; Jinyi Qi; Evren Asma; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2002-04       Impact factor: 10.048

3.  A technique for extracting physiological parameters and the required input function simultaneously from PET image measurements: theory and simulation study.

Authors:  D Feng; K P Wong; C M Wu; W C Siu
Journal:  IEEE Trans Inf Technol Biomed       Date:  1997-12

4.  Effects of temporal modelling on the statistical uncertainty of spatiotemporal distributions estimated directly from dynamic SPECT projections.

Authors:  B W Reutter; G T Gullberg; R H Huesman
Journal:  Phys Med Biol       Date:  2002-08-07       Impact factor: 3.609

5.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

6.  Study of direct and indirect parametric estimation methods of linear models in dynamic positron emission tomography.

Authors:  Charalampos Tsoumpas; Federico E Turkheimer; Kris Thielemans
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

7.  Spectral analysis of dynamic PET studies.

Authors:  V J Cunningham; T Jones
Journal:  J Cereb Blood Flow Metab       Date:  1993-01       Impact factor: 6.200

8.  Graphical evaluation of blood-to-brain transfer constants from multiple-time uptake data. Generalizations.

Authors:  C S Patlak; R G Blasberg
Journal:  J Cereb Blood Flow Metab       Date:  1985-12       Impact factor: 6.200

9.  Direct brain infusion of glial cell line-derived neurotrophic factor in Parkinson disease.

Authors:  Steven S Gill; Nikunj K Patel; Gary R Hotton; Karen O'Sullivan; Renée McCarter; Martin Bunnage; David J Brooks; Clive N Svendsen; Peter Heywood
Journal:  Nat Med       Date:  2003-03-31       Impact factor: 53.440

10.  A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET.

Authors:  Y Choi; S C Huang; R A Hawkins; W G Kuhle; M Dahlbom; C K Hoh; J Czernin; M E Phelps; H R Schelbert
Journal:  J Nucl Med       Date:  1993-03       Impact factor: 10.057

View more
  24 in total

Review 1.  Resolution modeling in PET imaging: theory, practice, benefits, and pitfalls.

Authors:  Arman Rahmim; Jinyi Qi; Vesna Sossi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

2.  Direct reconstruction of cardiac PET kinetic parametric images using a preconditioned conjugate gradient approach.

Authors:  Yothin Rakvongthai; Jinsong Ouyang; Bastien Guerin; Quanzheng Li; Nathaniel M Alpert; Georges El Fakhri
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

Review 3.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

4.  Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

Authors:  Mary Germino; Richard E Carson
Journal:  Med Phys       Date:  2017-12-30       Impact factor: 4.071

5.  Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection.

Authors:  Li Yang; Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2015-11-23       Impact factor: 10.048

6.  An optimization transfer algorithm for nonlinear parametric image reconstruction from dynamic PET data.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2012-08-08       Impact factor: 10.048

7.  PET image reconstruction using kernel method.

Authors:  Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2014-07-30       Impact factor: 10.048

8.  Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity.

Authors:  Kuang Gong; Jinxiu Cheng-Liao; Guobao Wang; Kevin T Chen; Ciprian Catana; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2018-04       Impact factor: 10.048

9.  Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

Authors:  Nicolas A Karakatsanis; Martin A Lodge; Y Zhou; Richard L Wahl; Arman Rahmim
Journal:  Phys Med Biol       Date:  2013-09-30       Impact factor: 3.609

10.  Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

Authors:  Nicolas A Karakatsanis; Martin A Lodge; Abdel K Tahari; Y Zhou; Richard L Wahl; Arman Rahmim
Journal:  Phys Med Biol       Date:  2013-09-30       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.