Literature DB >> 18436611

A new self-expandable nitinol stent for the treatment of wide-neck aneurysms: initial clinical experience.

J P P Peluso1, W J van Rooij, M Sluzewski, G N Beute.   

Abstract

BACKGROUND AND
PURPOSE: Stent systems for intracranial use are continuously improved. We report our initial experience using a new self-expanding easy-to-place nitinol stent (Enterprise) in the treatment of wide-neck intracranial aneurysms.
MATERIALS AND METHODS: Between January and October 2007, 16 aneurysms in 15 patients were treated with stent assistance. Aneurysm size was a mean of 13.2 mm (median, 12 mm; range, 7-30 mm). Eight aneurysms had reopened after prior coiling, and 8 aneurysms were primarily treated, 1 after acute subarachnoid hemorrhage. Response to antiplatelet premedication was tested with a P2Y12 assay before stent placement. On a 3D angiographic workstation, stent placement was simulated to assess vessel caliber and appropriate stent length.
RESULTS: In all aneurysms, the stent could be placed at the exact location as predicted from the computer simulation. Stent placement proved to be technically easy without the need for recapture in all patients. Although placement of the microcatheter through the stent struts and subsequent coil placement was challenging in some patients, coiling after stent placement resulted in complete or near-complete occlusion in all aneurysms. There were no technical or clinical complications. At 6 months, angiographic follow-up in 14 aneurysms revealed 4 aneurysms recanalized to 80% occlusion, 3 of which were additionally coiled.
CONCLUSION: In this small series, delivery and deployment of the Enterprise stent was technically easy. There were no technical or clinical complications. The device was valuable in the treatment of wide-neck aneurysms. The need for antiplatelet medication in patients treated with this and other stents remains a significant disadvantage.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18436611      PMCID: PMC8119146          DOI: 10.3174/ajnr.A1104

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

1.  Variability in platelet responsiveness to clopidogrel among 544 individuals.

Authors:  Victor L Serebruany; Steven R Steinhubl; Peter B Berger; Alex I Malinin; Deepak L Bhatt; Eric J Topol
Journal:  J Am Coll Cardiol       Date:  2005-01-18       Impact factor: 24.094

2.  Balloon-assisted coil embolization of intracranial aneurysms: incidence, complications, and angiography results.

Authors:  Menno Sluzewski; Willem Jan van Rooij; Guus N Beute; Peter C Nijssen
Journal:  J Neurosurg       Date:  2006-09       Impact factor: 5.115

3.  [Reconstruction technic in the treatment of wide-neck intracranial aneurysms. Long-term angiographic and clinical results. Apropos of 56 cases].

Authors:  J Moret; C Cognard; A Weill; L Castaings; A Rey
Journal:  J Neuroradiol       Date:  1997-06       Impact factor: 3.447

4.  Neck-bridge device for endovascular treatment of wide-neck bifurcation aneurysms: initial experience.

Authors:  J Raymond; F Guilbert; D Roy
Journal:  Radiology       Date:  2001-11       Impact factor: 11.105

5.  Initial clinical experience with a new self-expanding nitinol stent for the treatment of intracranial cerebral aneurysms: the Cordis Enterprise stent.

Authors:  Randall T Higashida; Van V Halbach; Christopher F Dowd; Louis Juravsky; Sean Meagher
Journal:  AJNR Am J Neuroradiol       Date:  2005-08       Impact factor: 3.825

6.  Usefulness of the Neuroform stent for the treatment of cerebral aneurysms: results at initial (3-6-mo) follow-up.

Authors:  David Fiorella; Felipe C Albuquerque; Vivek R Deshmukh; Cameron G McDougall
Journal:  Neurosurgery       Date:  2005-06       Impact factor: 4.654

7.  A new self-expanding nitinol stent (Enterprise) for the treatment of wide-necked intracranial aneurysms: initial clinical and angiographic results in 31 aneurysms.

Authors:  Werner Weber; Martin Bendszus; Bernhard Kis; Thierry Boulanger; László Solymosi; Dietmar Kühne
Journal:  Neuroradiology       Date:  2007-05-03       Impact factor: 2.804

8.  Evaluation of a neck-bridge device to assist endovascular treatment of wide-neck aneurysms of the anterior circulation.

Authors:  K De Keukeleire; P Vanlangenhove; L Defreyne
Journal:  AJNR Am J Neuroradiol       Date:  2007-10-10       Impact factor: 3.825

9.  Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: strategies in stent deployment and midterm follow-up.

Authors:  Alessandra Biondi; Vallabh Janardhan; Jeffrey M Katz; Kimberly Salvaggio; Howard A Riina; Y Pierre Gobin
Journal:  Neurosurgery       Date:  2007-09       Impact factor: 4.654

10.  Clopidogrel for coronary stenting: response variability, drug resistance, and the effect of pretreatment platelet reactivity.

Authors:  Paul A Gurbel; Kevin P Bliden; Bonnie L Hiatt; Christopher M O'Connor
Journal:  Circulation       Date:  2003-06-09       Impact factor: 29.690

View more
  28 in total

1.  Reversible intracranial parenchymal changes in MRI after MCA aneurysm treatment with stent-assisted coiling technique; possible nickel allergy.

Authors:  Sıla Ulus; Abdullah Yakupoğlu; Ercan Kararslan; Civan Işlak; Aksel Siva; Naci Koçer
Journal:  Neuroradiology       Date:  2012-06-01       Impact factor: 2.804

Review 2.  Materials and techniques for coiling of cerebral aneurysms: how much scientific evidence do we have?

Authors:  W Kurre; J Berkefeld
Journal:  Neuroradiology       Date:  2008-09-19       Impact factor: 2.804

Review 3.  Stents for intracranial wide-necked aneurysms: more than mechanical protection.

Authors:  Isabel Wanke; Michael Forsting
Journal:  Neuroradiology       Date:  2008-09-20       Impact factor: 2.804

4.  Microguidewire protection of wide-necked aneurysms incorporating orifices of tortuous acute-angled vessels: a novel approach.

Authors:  Young Dae Cho; Hyun-Seung Kang; Jeong Eun Kim; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-04-23       Impact factor: 2.804

5.  Modified coil protection for proper coil frame configuration in wide-necked aneurysms.

Authors:  Young Dae Cho; Jong Kook Rhim; Jeong Jin Park; Jin Pyeong Jeon; Hyun-Seung Kang; Jeong Eun Kim; Won-Sang Cho; Moon Hee Han
Journal:  Neuroradiology       Date:  2015-03-28       Impact factor: 2.804

6.  Stenting from the vertebral artery to the posterior inferior cerebellar artery.

Authors:  M J Kim; J Chung; S L Kim; H G Roh; B J Kwon; B-s Kim; T H Kim; B M Kim; Y S Shin
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-03       Impact factor: 3.825

7.  Coil embolization in precommunicating (A1) segment aneurysms of anterior cerebral artery.

Authors:  Young Dae Cho; Jun Hyong Ahn; Seung Chai Jung; Chang Hun Kim; Hyun-Seung Kang; Jeong Eun Kim; Young Je Son; Moon Hee Han
Journal:  Neuroradiology       Date:  2014-01-26       Impact factor: 2.804

8.  Late adverse events in coiled ruptured aneurysms with incomplete occlusion at 6-month angiographic follow-up.

Authors:  S P Ferns; C B L M Majoie; M Sluzewski; W J van Rooij
Journal:  AJNR Am J Neuroradiol       Date:  2009-10-15       Impact factor: 3.825

9.  Retrograde stenting through the posterior cerebral artery in coil embolization of the posterior communicating artery aneurysm.

Authors:  Young Dae Cho; Kang Min Kim; Woong Jae Lee; Hyun-Seung Kang; Jeong Eun Kim; Moon Hee Han
Journal:  Neuroradiology       Date:  2013-03-12       Impact factor: 2.804

10.  The enterprise stent for the treatment of intracranial aneurysms: stenting strategies.

Authors:  Horst Urbach; Henriette Tschampa; Attila Kovács; Susanne Greschus; Johannes Schramm
Journal:  Klin Neuroradiol       Date:  2009-08-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.