Literature DB >> 15987593

Treatment of a middle cerebral artery bifurcation aneurysm using a double neuroform stent "Y" configuration and coil embolization: technical case report.

Sepehr Sani1, Demetrius Klee Lopes.   

Abstract

OBJECTIVE AND IMPORTANCE: Wide-necked cerebral aneurysms have been particularly difficult to treat using coil embolization. The introduction of the first intracranial flexible stent (Neuroform stent; Boston Scientific/Target, Fremont, CA) has provided a great advantage to this dilemma by forming a bridge across the aneurysm neck and allowing the packing of coils. Despite this advancement, some parent vessel bifurcation aneurysms can still remain elusive to single stent and coiling technique. CLINICAL
PRESENTATION: A 55-year-old woman presented for a routine follow-up angiogram. Her past history was significant for a subarachnoid hemorrhage and clipping of an anterior communicating aneurysm with full recovery. An incidental new right middle cerebral artery aneurysm was found on the angiogram. We report here a case of an unruptured asymptomatic wide-neck middle cerebral artery bifurcation aneurysm that was treated with a novel endovascular repair. INTERVENTION: The aneurysm was successfully treated using a double stent "Y" configuration and coil embolization technique using the Neuroform stent. Technical aspects are discussed. Perioperative management issues and potential pitfalls are also considered.
CONCLUSION: Double stenting in "Y" configuration and coiling is feasible. This technique should increase the ability to endovascularly treat wide-necked aneurysms.

Entities:  

Mesh:

Year:  2005        PMID: 15987593     DOI: 10.1227/01.neu.0000163684.75204.cd

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  27 in total

1.  Y-crossing of braided stents with stents and flow diverters does not cause significant stenosis in bench-top studies.

Authors:  Alina Makoyeva; Tim E Darsaut; Igor Salazkin; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

2.  Hybrid, Y-configured, dual stent-assisted coil embolization in the treatment of wide-necked bifurcation aneurysms.

Authors:  Erol Akgul; Tugsan Balli; Erol H Aksungur
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

3.  Stent-assisted coil embolization of complex wide-necked bifurcation cerebral aneurysms using the "waffle cone" technique. A review of ten consecutive cases.

Authors:  W Liu; D K Kung; B Policeni; J D Rossen; P M Jabbour; D M Hasan
Journal:  Interv Neuroradiol       Date:  2012-03-16       Impact factor: 1.610

4.  Y-stent-assisted coil embolization of wide-neck intracranial aneurysms. A single center experience.

Authors:  E Akgul; E Aksungur; T Balli; B Onan; D M Yilmaz; S Bicakci; T Erman
Journal:  Interv Neuroradiol       Date:  2011-04-18       Impact factor: 1.610

5.  The impact of stent design on the structural mechanics of the crossing Y-stent: an in vitro study.

Authors:  Chang-Young Lee; Seong-Ho Park; Chang-Hyun Kim; Goetz Benndorf
Journal:  Neuroradiology       Date:  2014-05-28       Impact factor: 2.804

6.  Double stent-assisted coil embolization treatment for bifurcation aneurysms: immediate treatment results and long-term angiographic outcome.

Authors:  K Yavuz; S Geyik; S Cekirge; I Saatci
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-28       Impact factor: 3.825

7.  Quantification of hemodynamic changes induced by virtual placement of multiple stents across a wide-necked basilar trunk aneurysm.

Authors:  Minsuok Kim; Elad I Levy; Hui Meng; L Nelson Hopkins
Journal:  Neurosurgery       Date:  2007-12       Impact factor: 4.654

8.  Middle cerebral artery aneurysm surgery after stent misplacement: A case report.

Authors:  Abdul Rahman Al-Schameri; Manuel Lunzer; Cornelia Daller; Michael Kral; Monika Killer
Journal:  Interv Neuroradiol       Date:  2015-11-19       Impact factor: 1.610

9.  "Y" and "X" stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms.

Authors:  B Bartolini; R Blanc; S Pistocchi; H Redjem; M Piotin
Journal:  AJNR Am J Neuroradiol       Date:  2014-07-24       Impact factor: 3.825

10.  Treatment of a wide-necked aneurysm of the anterior cerebral artery using two Enterprise stents in "Y"-configuration stenting technique and coil embolization: a technical note.

Authors:  Stefan Rohde; Martin Bendszus; Marius Hartmann; Stefan Hähnel
Journal:  Neuroradiology       Date:  2009-10-21       Impact factor: 2.804

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.