Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus.

Rebecca K Tanner1, Kate L Fuller, Megan L R Ross.   

Abstract

Three portable blood lactate analysers, Lactate Pro (LP), Lactate Scout (LS) and Lactate Plus (L(+)), were evaluated. Analyser reliability and accuracy was assessed. For reliability, intra- and inter-analyser comparisons demonstrated that the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra-TE = 0.4, inter-TE = 0.4 mM) displayed greater overall reliability than the LS (intra-TE = 1.0, inter-TE = 0.8 mM). At BLa < 4.0 mM, the LP (intra-TE = 0.1 mM) demonstrated greater reliability than the LS (intra-TE = 0.5 mM) and L(+) (intra-TE = 0.4 mM). At BLa > 8.0 mM, the LP (intra-TE = 0.5 mM, inter-TE = 0.4 mM) and L(+) (intra- and inter-TE = 0.4 mM) displayed greater reliability than the LS (intra-TE = 1.1 mM, inter-TE = 0.9 mM). For accuracy, the L(+) (SEE = 0.6 mM) compared more favourably to the LP than the LS (SEE = 1.1 mM). At BLa approximately 1.0-18.0 mM, the LS produced values that were up to 0.9 mM higher than the LP; the L(+) produced BLa that were within +/-0.1 mM. All portable analysers tended to under-read the ABL 700 analyser. The suitability of the LP and L(+) as accurate analysers is supported by strong correlations (r = 0.91 and r = 0.94) and limits of agreement <or=2.1 mM. This study showed that the LP and L(+), compared well to each other, displayed good reliability and accuracy when compared to a laboratory-based analyser. Although the LS also displayed relatively good reliability, it was not as reliable or accurate as the LP or L(+).

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20145946     DOI: 10.1007/s00421-010-1379-9

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  12 in total

Review 1.  The effect of endurance training on parameters of aerobic fitness.

Authors:  A M Jones; H Carter
Journal:  Sports Med       Date:  2000-06       Impact factor: 11.136

2.  Comparison of the Lactate Pro and Analox GM7 blood lactate analysers.

Authors:  K A van Someren; G Howatson; D Nunan; R Thatcher; R Shave
Journal:  Int J Sports Med       Date:  2005-10       Impact factor: 3.118

3.  Control of training in middle- and long-distance running by means of the individual anaerobic threshold.

Authors:  B Coen; L Schwarz; A Urhausen; W Kindermann
Journal:  Int J Sports Med       Date:  1991-12       Impact factor: 3.118

4.  A comparison of the lactate Pro, Accusport, Analox GM7 and Kodak Ektachem lactate analysers in normal, hot and humid conditions.

Authors:  L R Mc Naughton; D Thompson; G Philips; K Backx; L Crickmore
Journal:  Int J Sports Med       Date:  2002-02       Impact factor: 3.118

5.  Evaluation of the Lactate Pro blood lactate analyser.

Authors:  D B Pyne; T Boston; D T Martin; A Logan
Journal:  Eur J Appl Physiol       Date:  2000-05       Impact factor: 3.078

6.  Blood lactate. Implications for training and sports performance.

Authors:  I Jacobs
Journal:  Sports Med       Date:  1986 Jan-Feb       Impact factor: 11.136

7.  Blood lactate parameters related to aerobic capacity and endurance performance.

Authors:  T Yoshida; M Chida; M Ichioka; Y Suda
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

8.  Effects of training on lactate production and removal during progressive exercise in humans.

Authors:  H S MacRae; S C Dennis; A N Bosch; T D Noakes
Journal:  J Appl Physiol (1985)       Date:  1992-05

9.  Effect of measuring blood lactate concentrations using different automated lactate analysers on blood lactate transition thresholds.

Authors:  J D Buckley; P C Bourdon; S M Woolford
Journal:  J Sci Med Sport       Date:  2003-12       Impact factor: 4.319

10.  Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer.

Authors:  Carlo Baldari; Valerio Bonavolontà; Gian Pietro Emerenziani; Maria Chiara Gallotta; Antonio José Silva; Laura Guidetti
Journal:  Eur J Appl Physiol       Date:  2009-06-14       Impact factor: 3.078

View more
  44 in total

1.  Impact of a soccer match on the cardiac autonomic control of referees.

Authors:  Daniel Alexandre Boullosa; Laurinda Abreu; José Luis Tuimil; Anthony Scott Leicht
Journal:  Eur J Appl Physiol       Date:  2011-10-14       Impact factor: 3.078

2.  Reliability and accuracy of six hand-held blood lactate analysers.

Authors:  Jacinta M Bonaventura; Ken Sharpe; Emma Knight; Kate L Fuller; Rebecca K Tanner; Christopher J Gore
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

3.  Determination of critical power in trained rowers using a three-minute all-out rowing test.

Authors:  Ching-Feng Cheng; Yi-Shan Yang; Hui-Mei Lin; Chia-Lun Lee; Chun-Yi Wang
Journal:  Eur J Appl Physiol       Date:  2011-07-19       Impact factor: 3.078

4.  Brain oxygenation declines in elite Kenyan runners during a maximal interval training session.

Authors:  Jordan Santos-Concejero; F Billaut; L Grobler; J Oliván; T D Noakes; R Tucker
Journal:  Eur J Appl Physiol       Date:  2017-03-20       Impact factor: 3.078

5.  Proposal for a Specific Aerobic Test for Football Players: The "Footeval".

Authors:  Christophe Manouvrier; Johan Cassirame; Saïd Ahmaidi
Journal:  J Sports Sci Med       Date:  2016-12-01       Impact factor: 2.988

6.  Cardiorespiratory and neuromuscular deconditioning in fatigued and non-fatigued breast cancer survivors.

Authors:  Sarah E Neil; Riggs J Klika; S Jayne Garland; Donald C McKenzie; Kristin L Campbell
Journal:  Support Care Cancer       Date:  2012-09-28       Impact factor: 3.603

7.  Validating a point of care lactate meter in adult patients with sepsis presenting to the emergency department of a tertiary care hospital of a low- to middle-income country.

Authors:  Muhammad Akbar Baig; Hira Shahzad; Erfan Hussain; Asad Mian
Journal:  World J Emerg Med       Date:  2017

8.  Increase in serum growth hormone induced by electrical stimulation of muscle combined with blood flow restriction.

Authors:  Yoshitaka Inagaki; Haruhiko Madarame; Mitsuo Neya; Naokata Ishii
Journal:  Eur J Appl Physiol       Date:  2011-03-12       Impact factor: 3.078

9.  Effects of compression garments on recovery following intermittent exercise.

Authors:  Cathryn L Pruscino; Shona Halson; Mark Hargreaves
Journal:  Eur J Appl Physiol       Date:  2013-01-12       Impact factor: 3.078

10.  Effects of a high-carbohydrate versus high-protein meal on acute responses to hypoxia at rest and exercise.

Authors:  Keyne Charlot; Aurélien Pichon; Jean-Paul Richalet; Didier Chapelot
Journal:  Eur J Appl Physiol       Date:  2012-08-24       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.