Reliability and accuracy of six hand-held blood lactate analysers.

Jacinta M Bonaventura1, Ken Sharpe2, Emma Knight3, Kate L Fuller1, Rebecca K Tanner1, Christopher J Gore4.   

Abstract

The reliability and accuracy of five portable blood lactate (BLa) analysers (Lactate Pro, Lactate Pro2, Lactate Scout+, Xpress™, and Edge) and one handheld point-of-care analyser (i-STAT) were compared to a criterion (Radiometer ABL90). Two devices of each brand of analyser were assessed using 22 x 6 mL blood samples taken from five subjects at rest and during exercise who generated lactate ranging ~1-23 mM. Each sample was measured simultaneously ~6 times on each device. Reliability was assessed as the within-sample standard deviation (wsSD) of the six replicates; accuracy as the bias compared with the ABL90; and overall error (the root mean squared error (√MSE)) was calculated as the square root of (wsSD(2) and bias(2)). The √MSE indicated that both the Edge and Xpress had low total error (~0-2 mM) for lactate concentrations <15 mM, whereas the Edge and Lactate Pro2 were the better of the portable analysers for concentrations >15 mM. In all cases, bias (negative) was the major contribution to the √MSE. In conclusion, in a clinical setting where BLa is generally <15 mM the Edge and Xpress devices are relevant, but for athlete testing where peak BLa is important for training prescription the Edge and Lactate Pro2 are preferred. Key pointsThe reliability of five common portable blood lactate analysers were generally <0.5 mM for concentrations in the range of ~1.0-10 mM.For all five portable analysers, the analytical error within a brand was much smaller than the biological variation in blood lactate (BLa).Compared with a criterion blood lactate analyser, there was a tendency for all portable analysers to under-read (i.e. a negative bias), which was particularly evident at the highest concentrations (BLa ~15-23 mM).The practical application of these negative biases would overestimate the ability of the athlete and prescribe a training intensity that would be too high.

Entities:  

Keywords:  Bias; analytical performance; precision; root mean squared error

Year:  2015        PMID: 25729309      PMCID: PMC4306774     

Source DB:  PubMed          Journal:  J Sports Sci Med        ISSN: 1303-2968            Impact factor:   2.988


  21 in total

1.  The stability of lactate concentration in preserved blood microsamples.

Authors:  H M McCaughan; R Z McRae; H K Smith
Journal:  Int J Sports Med       Date:  2000-01       Impact factor: 3.118

2.  Comparison of the Lactate Pro and Analox GM7 blood lactate analysers.

Authors:  K A van Someren; G Howatson; D Nunan; R Thatcher; R Shave
Journal:  Int J Sports Med       Date:  2005-10       Impact factor: 3.118

3.  Effects of time, temperature and blood cell counts on levels of lactate in heparinized whole blood gas samples.

Authors:  O Calatayud; J M Tenías
Journal:  Scand J Clin Lab Invest       Date:  2003       Impact factor: 1.713

4.  Evaluation of the Lactate Pro blood lactate analyser.

Authors:  D B Pyne; T Boston; D T Martin; A Logan
Journal:  Eur J Appl Physiol       Date:  2000-05       Impact factor: 3.078

5.  Anaerobic threshold and respiratory gas exchange during exercise.

Authors:  K Wasserman; B J Whipp; S N Koyl; W L Beaver
Journal:  J Appl Physiol       Date:  1973-08       Impact factor: 3.531

6.  Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus.

Authors:  Rebecca K Tanner; Kate L Fuller; Megan L R Ross
Journal:  Eur J Appl Physiol       Date:  2010-02-10       Impact factor: 3.078

7.  Stability of plasma lactate in vitro in the presence of antiglycolytic agents.

Authors:  R Astles; C P Williams; F Sedor
Journal:  Clin Chem       Date:  1994-07       Impact factor: 8.327

8.  Temperature and time stability of whole blood lactate: implications for feasibility of pre-hospital measurement.

Authors:  Christopher W Seymour; David Carlbom; Colin R Cooke; Timothy R Watkins; Eileen M Bulger; Thomas D Rea; Geoffrey S Baird
Journal:  BMC Res Notes       Date:  2011-05-30

9.  Reliability and variability of running economy in elite distance runners.

Authors:  Philo U Saunders; David B Pyne; Richard D Telford; John A Hawley
Journal:  Med Sci Sports Exerc       Date:  2004-11       Impact factor: 5.411

10.  Determination of the effect of in vitro time, temperature, and tourniquet use on whole blood venous point-of-care lactate concentrations.

Authors:  Alan E Jones; Matthew M Leonard; Jackeline Hernandez-Nino; Jeffrey A Kline
Journal:  Acad Emerg Med       Date:  2007-05-18       Impact factor: 3.451

View more
  25 in total

1.  The protective effects of acute cardiovascular exercise on the interference of procedural memory.

Authors:  J S Jo; J Chen; S Riechman; M Roig; D L Wright
Journal:  Psychol Res       Date:  2018-04-10

2.  Hyperspectral enhanced reality (HYPER) for anatomical liver resection.

Authors:  Takeshi Urade; Eric Felli; Manuel Barberio; Mahdi Al-Taher; Emanuele Felli; Laurent Goffin; Vincent Agnus; Giuseppe Maria Ettorre; Jacques Marescaux; Didier Mutter; Michele Diana
Journal:  Surg Endosc       Date:  2020-04-27       Impact factor: 4.584

3.  Accuracy of a point-of-care blood lactate measurement device in a prehospital setting.

Authors:  Louise Houlberg Walther; Floor Zegers; Mads Nybo; Christian Backer Mogensen; Erika Frischknecht Christensen; Annmarie Touborg Lassen; Søren Mikkelsen
Journal:  J Clin Monit Comput       Date:  2022-01-27       Impact factor: 2.502

4.  Silicone ring tourniquet versus pneumatic cuff tourniquet in total knee arthroplasty surgery: A randomised comparative study.

Authors:  Vicente J León-Muñoz; Alonso J Lisón-Almagro; César H Hernández-García; Mirian López-López
Journal:  J Orthop       Date:  2018-05-07

5.  Prehospital Lactate Predicts Need for Resuscitative Care in Non-hypotensive Trauma Patients.

Authors:  Alexander E St John; Andrew M McCoy; Allison G Moyes; Francis X Guyette; Eileen M Bulger; Michael R Sayre
Journal:  West J Emerg Med       Date:  2018-02-12

6.  Reliability of forearm oxygen uptake during handgrip exercise: assessment by ultrasonography and venous blood gas.

Authors:  Stian K Nyberg; Ole Kristian Berg; Jan Helgerud; Eivind Wang
Journal:  Physiol Rep       Date:  2018-05

7.  Comparison of oxygen uptake during cycle ergometry with and without functional electrical stimulation in patients with COPD: protocol for a randomised, single-blind, placebo-controlled, cross-over trial.

Authors:  Clément Medrinal; Guillaume Prieur; David Debeaumont; Aurora Robledo Quesada; Yann Combret; Jean Quieffin; Olivier Contal; Bouchra Lamia
Journal:  BMJ Open Respir Res       Date:  2016-04-12

8.  Lactate point-of-care testing for acidosis: Cross-comparison of two devices with routine laboratory results.

Authors:  Remco van Horssen; Teska N Schuurman; Monique J M de Groot; Bernadette S Jakobs
Journal:  Pract Lab Med       Date:  2015-12-24

9.  Physiological parameter values in greyhounds before and after high-intensity exercise.

Authors:  Francisco Javier Pellegrino; Analía Risso; Pablo G Vaquero; Yanina A Corrada
Journal:  Open Vet J       Date:  2018-03-03

10.  Particularities of the changes in young swimmers' body adaptation to the stimuli of physical and mental stress in sports training process.

Authors:  Liliana Mihailescu; Nicoleta Dubiţ; Liviu Emanuel Mihailescu; Vladimir Potop
Journal:  PeerJ       Date:  2021-06-23       Impact factor: 2.984

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.