A comparison of the lactate Pro, Accusport, Analox GM7 and Kodak Ektachem lactate analysers in normal, hot and humid conditions.

L R Mc Naughton1, D Thompson, G Philips, K Backx, L Crickmore.   

Abstract

This study aimed to compare the performance of a new portable lactate analyser against other standard laboratory methods in three conditions, normal (20 +/- 1.3 degrees C; 40 +/- 5 % RH), hot (40 +/- 2.5 degrees C; 40 +/- 5 % RH), and humid (20 +/- 1.1 degrees C; 82 +/- 6 % RH) conditions. Seven healthy males, ([Mean +/- SE]: age, 26.3 +/- 1.3 yr; height, 177.7 +/- 1.6 cm; weight, 77.4 +/- 0.9 kg, .VO(2)max, 56.1 +/- 1.9 ml x kg x min(-1)) undertook a maximal cycle ergometry test to exhaustion in the three conditions. Blood was taken every 3 min at the end of each stage and was analysed using the Lactate Pro LT-1710, the Accusport, the Analox GM7 and the Kodak Ektachem systems. The MANOVA (Analyser Type x Condition x Workload) indicated no interaction effect (F(42,660), = 0.45, p > 0.99, Power = 0.53). The data across all workloads indicated that the machines measured significantly differently to each other (F(4,743) = 14.652, p < 0.0001, Power = 1.00). The data were moderately to highly correlated. We conclude that the Lactate Pro is a simple and effective measurement device for taking blood lactate in a field or laboratory setting. However, we would caution against using this machine to compare data from other machines.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11842361     DOI: 10.1055/s-2002-20133

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  21 in total

1.  Reliability and accuracy of six hand-held blood lactate analysers.

Authors:  Jacinta M Bonaventura; Ken Sharpe; Emma Knight; Kate L Fuller; Rebecca K Tanner; Christopher J Gore
Journal:  J Sports Sci Med       Date:  2015-03-01       Impact factor: 2.988

2.  Energy cost of swimming of elite long-distance swimmers.

Authors:  P Zamparo; M Bonifazi; M Faina; A Milan; F Sardella; F Schena; C Capelli
Journal:  Eur J Appl Physiol       Date:  2005-05-11       Impact factor: 3.078

3.  Differences between the Vastus Lateralis and Gastrocnemius Lateralis in the Assessment Ability of Breakpoints of Muscle Oxygenation for Aerobic Capacity Indices During an Incremental Cycling Exercise.

Authors:  Bangde Wang; Guodong Xu; Qingping Tian; Jinyan Sun; Bailei Sun; Lei Zhang; Qingming Luo; Hui Gong
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

4.  Blood lactate measurements and analysis during exercise: a guide for clinicians.

Authors:  Matthew L Goodwin; James E Harris; Andrés Hernández; L Bruce Gladden
Journal:  J Diabetes Sci Technol       Date:  2007-07

5.  Determination of ubiquinone in blood by high-performance liquid chromatography with post-column fluorescence derivatization using 2-cyanoacetamide.

Authors:  Yukio Nohara; Junko Suzuki; Hiroaki Kubo
Journal:  J Fluoresc       Date:  2011-06-07       Impact factor: 2.217

6.  Comparisons of local and systemic aerobic fitness parameters between finswimmers with different athlete grade levels.

Authors:  Bangde Wang; Qingping Tian; Zhongxing Zhang; Hui Gong
Journal:  Eur J Appl Physiol       Date:  2011-05-25       Impact factor: 3.078

7.  Somatosensory evoked potentials and blood lactate levels.

Authors:  Valentina Perciavalle; Giovanna Alagona; Giulia De Maria; Giuseppe Rapisarda; Erminio Costanzo; Vincenzo Perciavalle; Marinella Coco
Journal:  Neurol Sci       Date:  2015-04-17       Impact factor: 3.307

Review 8.  Lactate threshold concepts: how valid are they?

Authors:  Oliver Faude; Wilfried Kindermann; Tim Meyer
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

9.  Cardiorespiratory and Metabolic Responses to Loaded Half Squat Exercise Executed at an Intensity Corresponding to the Lactate Threshold.

Authors:  José Luis Maté-Muñoz; Raúl Domínguez; Manuel Barba; Antonio J Monroy; Bárbara Rodríguez; Pedro Ruiz-Solano; Manuel V Garnacho-Castaño
Journal:  J Sports Sci Med       Date:  2015-08-11       Impact factor: 2.988

10.  Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma - method-comparison evaluations.

Authors:  Sérgio Monteiro de Almeida; Jennifer Marquie-Beck; Archana Bhatt; Scott Letendre; Allen McCutchan; Ron Ellis
Journal:  Arq Neuropsiquiatr       Date:  2014-07       Impact factor: 1.420

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.