Literature DB >> 14723391

Effect of measuring blood lactate concentrations using different automated lactate analysers on blood lactate transition thresholds.

J D Buckley1, P C Bourdon, S M Woolford.   

Abstract

This study investigated the effect of using three automated blood lactate analysers (Accusport, Lactate Pro, YSI 1500 Sport) on blood lactate transition thresholds (BLTT). Blood lactate concentrations were measured using the three analysers in rowers (n = 17) and kayakers (n = 6) during incremental exercise. The BLTT determined were: 1) ADAPT lactate threshold (data point preceding lactate increase of > or = 0.4 mmol x l(-1)), 2) log-log lactate threshold (point of lactate increase when log lactate plotted against log of relevant exercise parameter), 3) DMAX anaerobic threshold, 4) ADAPT anaerobic threshold (modified DMAX method), 5) Onset of blood lactate accumulation (OBLA, fixed blood lactate concentration of 4 mmol x l(-1)). Measurements of blood lactate concentration differed between analysers (p < 0.0001), resulting in BLTT differing between analysers when expressed as a blood lactate concentration (p < 0.0001), or when the BLTT was defined as a fixed blood lactate concentration (e.g. OBLA) (p < 0.0001). When expressed as a power output or heart rate using BLTT based on relative changes in lactate concentration (log-log, ADAPT and DMAX thresholds) the values were similar between analysers (p > 0.05), except the Accusport provided higher values for the log-log lactate threshold (p < 0.0001). We concluded that, despite providing significantly different lactate concentrations, unless the Accusport was used to determine the log-log lactate threshold, or values were expressed as a blood lactate concentration, the use of different analysers had little effect on the BLTT.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14723391     DOI: 10.1016/s1440-2440(03)80267-0

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  16 in total

1.  Working memory and blood lactate levels.

Authors:  Valentina Perciavalle; Tiziana Maci; Vincenzo Perciavalle; Simona Massimino; Marinella Coco
Journal:  Neurol Sci       Date:  2015-07-14       Impact factor: 3.307

2.  Relationship of high blood lactate levels with latency of visual-evoked potentials.

Authors:  Marinella Coco; Giovanna Alagona; Giulia De Maria; Giuseppe Rapisarda; Erminio Costanzo; Vincenzo Perciavalle; Valentina Perciavalle
Journal:  Neurol Sci       Date:  2014-11-26       Impact factor: 3.307

3.  Comparison of physiological response to cardiopulmonary exercise testing among cancer survivors and healthy controls.

Authors:  Riggs J Klika; Katharina S Golik; Scott N Drum; Kathleen E Callahan; William G Thorland
Journal:  Eur J Appl Physiol       Date:  2010-12-03       Impact factor: 3.078

4.  Evaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus.

Authors:  Rebecca K Tanner; Kate L Fuller; Megan L R Ross
Journal:  Eur J Appl Physiol       Date:  2010-02-10       Impact factor: 3.078

Review 5.  Lactate threshold concepts: how valid are they?

Authors:  Oliver Faude; Wilfried Kindermann; Tim Meyer
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

6.  Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF) and plasma - method-comparison evaluations.

Authors:  Sérgio Monteiro de Almeida; Jennifer Marquie-Beck; Archana Bhatt; Scott Letendre; Allen McCutchan; Ron Ellis
Journal:  Arq Neuropsiquiatr       Date:  2014-07       Impact factor: 1.420

Review 7.  Point-of-care diagnostics for niche applications.

Authors:  Brian M Cummins; Frances S Ligler; Glenn M Walker
Journal:  Biotechnol Adv       Date:  2016-02-01       Impact factor: 14.227

8.  Accuracy, reliability, linearity of Accutrend and Lactate Pro versus EBIO plus analyzer.

Authors:  Carlo Baldari; Valerio Bonavolontà; Gian Pietro Emerenziani; Maria Chiara Gallotta; Antonio José Silva; Laura Guidetti
Journal:  Eur J Appl Physiol       Date:  2009-06-14       Impact factor: 3.078

9.  Effects of General Fatigue Induced by Exhaustive Exercise on Posture and Gait Stability of Healthy Young Men.

Authors:  Marinella Coco; Donatella Di Corrado; Francesco Cirillo; Chiara Iacono; Vincenzo Perciavalle; Andrea Buscemi
Journal:  Behav Sci (Basel)       Date:  2021-05-08

10.  A method-comparison study regarding the validity and reliability of the Lactate Plus analyzer.

Authors:  Sarah Hart; Kathryn Drevets; Micah Alford; Amanda Salacinski; Brian E Hunt
Journal:  BMJ Open       Date:  2013-02-27       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.