Literature DB >> 2013417

The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

P Duroux1, C Emde, P Bauerfeind, C Francis, A Grisel, L Thybaud, D Arstrong, C Depeursinge, A L Blum.   

Abstract

Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorporating an integral reference electrode. In vitro studies showed that both ISFET and glass electrodes (440-M4, Ingold, Switzerland) have a linear response over the pH range 1.3-8.0 and that they are comparable with regard to response time and 24 hour drift. Twenty one hour intragastric pH recordings were performed simultaneously in eight healthy volunteers using a glass electrode and an ISFET electrode, placed no more than 2 mm apart in a combined assembly. This was located in the gastric corpus under fluoroscopic control. The 21 hour pH curves recorded by each electrode type showed identical patterns: an early morning rise in pH with three meal-associated pH peaks lasting for about two to three hours. The means of the 21 hour pH medians were 2.09 and 2.07 as measured by the glass and the ISFET electrodes respectively. Thus, ISFETs are suitable for the construction of inexpensive and hence disposable multichannel pH monitoring assemblies of small diameter. Provided that they can be produced in large numbers with appropriate technical support, ISFETs have the potential to replace glass electrodes for long term monitoring of gastrointestinal luminal acidity.

Entities:  

Mesh:

Year:  1991        PMID: 2013417      PMCID: PMC1378826          DOI: 10.1136/gut.32.3.240

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  18 in total

1.  Day-to-day variation of 24-hour intragastric acidity.

Authors:  H S Merki; L Witzel; R P Walt; E Cohnen; K Harre; J Heim; A Mappes; J Röhmel
Journal:  Gastroenterology       Date:  1988-04       Impact factor: 22.682

2.  Electrodes for 24 hours pH monitoring--a comparative study.

Authors:  G McLauchlan; J M Rawlings; M L Lucas; R F McCloy; G P Crean; K E McColl
Journal:  Gut       Date:  1987-08       Impact factor: 23.059

3.  Identical 24-hour gastric pH profiles when using intragastric antimony or glass electrodes or aspirated gastric juice.

Authors:  J Andersen; J Naesdal; M Ström
Journal:  Scand J Gastroenterol       Date:  1988-04       Impact factor: 2.423

4.  Plastic pH electrodes for the measurement of gastrointestinal pH.

Authors:  J M Rawlings; M L Lucas
Journal:  Gut       Date:  1985-02       Impact factor: 23.059

Review 5.  Technical aspects of intraluminal pH-metry in man: current status and recommendations.

Authors:  C Emde; A Garner; A L Blum
Journal:  Gut       Date:  1987-09       Impact factor: 23.059

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Duodenal bulb pH in normal subjects.

Authors:  S Hannibal; S J Rune
Journal:  Eur J Clin Invest       Date:  1983-12       Impact factor: 4.686

8.  In vivo experiments with a pH-ISFET electrode.

Authors:  S J Schepel; N F de Rooij; G Koning; B Oeseburg; W G Zijlstra
Journal:  Med Biol Eng Comput       Date:  1984-01       Impact factor: 2.602

9.  Long-term ambulatory gastric pH monitoring: validation of a new method and effect of H2-antagonists.

Authors:  C J Fimmel; A Etienne; T Cilluffo; C von Ritter; T Gasser; J P Rey; P Caradonna-Moscatelli; F Sabbatini; F Pace; H W Bühler
Journal:  Gastroenterology       Date:  1985-06       Impact factor: 22.682

10.  Optimal thresholds, sensitivity, and specificity of long-term pH-metry for the detection of gastroesophageal reflux disease.

Authors:  N E Schindlbeck; C Heinrich; A König; A Dendorfer; F Pace; S A Müller-Lissner
Journal:  Gastroenterology       Date:  1987-07       Impact factor: 22.682

View more
  6 in total

1.  Low-power wireless electronic capsule for long-term gastrointestinal monitoring.

Authors:  Kai Zhao; Guozheng Yan; Li Lu; Fei Xu
Journal:  J Med Syst       Date:  2015-01-29       Impact factor: 4.460

2.  New method for improving accuracy of 24-hour continuous intragastric pH-metry. Reflections on physiological and pharmacological studies.

Authors:  G S Mela; V Savarino; A Malesci; F Di Mario; P Sossai; S Vigneri; A Zambotti
Journal:  Dig Dis Sci       Date:  1994-07       Impact factor: 3.199

3.  Gastroesophageal reflux: the features in elderly patients.

Authors:  Xun Huang; Hui-Ming Zhu; Chuan-Zhen Deng; G Bianchi Porro; O Sangaletti; F Pace
Journal:  World J Gastroenterol       Date:  1999-10       Impact factor: 5.742

Review 4.  Ambulatory esophageal pH monitoring: technique, interpretations, and clinical indications.

Authors:  Radha K Dhiman; Vivek A Saraswat; Subhash R Naik
Journal:  Dig Dis Sci       Date:  2002-02       Impact factor: 3.199

5.  Antioxidant protection against oxidant-induced damage in cultured gastric mucosal cells.

Authors:  H Hiraishi; N Yajima; N Yamaguchi; M Ishida; Y Katoh; T Harada; A Terano; K J Ivey
Journal:  Gastroenterol Jpn       Date:  1993-05

Review 6.  Interfacial structures and properties of organic materials for biosensors: an overview.

Authors:  Yan Zhou; Cheng-Wei Chiu; Hong Liang
Journal:  Sensors (Basel)       Date:  2012-11-06       Impact factor: 3.576