Literature DB >> 3967838

Plastic pH electrodes for the measurement of gastrointestinal pH.

J M Rawlings, M L Lucas.   

Abstract

Plastic electrodes have been developed for measuring pH in the human gastrointestinal tract. The electrodes have a plastic hydrogen ion sensitive membrane sealed to a length of fluid filled PVC tubing. Two recently developed hydrogen ion sensitive ligands have been examined. Their operational characteristics have been described. These electrodes have an electrical response of 52 to 58 mV/pH unit change in the range pH 4-9, with a diminished response outwith this range. They have a low resistance value and a fast response time of one second to reach 90% of their maximum response. The electrodes can be passed down the biopsy channel of an endoscope to obtain mucosal pH readings under direct vision. Readings obtained in this way using plastic electrodes are comparable to those obtained with glass electrodes. Alternatively, these electrodes can be joined to a Crosby capsule, allowing continuous recording of mucosal pH through to the jejunum during jejunal biopsy procedures. These electrodes can be used repeatedly or may be acceptable as inexpensive disposable items for sterile clinical use.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3967838      PMCID: PMC1432423          DOI: 10.1136/gut.26.2.203

Source DB:  PubMed          Journal:  Gut        ISSN: 0017-5749            Impact factor:   23.059


  5 in total

1.  pH profile of gut as measured by radiotelemetry capsule.

Authors:  B W Watson; S J Meldrum; H C Riddle; R L Brown; G E Sladen
Journal:  Br Med J       Date:  1972-04-08

2.  Gastric acid secretion and succinic dehydrogenase in parietal cells, with special reference to the effect of anticholinergic drugs.

Authors:  E Gravgaard
Journal:  Scand J Gastroenterol       Date:  1968       Impact factor: 2.423

3.  Intraluminal pH of duodenum and jejunum in fasting subjects with normal and abnormal gastric or pancreatic function.

Authors:  A Benn; W T Cooke
Journal:  Scand J Gastroenterol       Date:  1971       Impact factor: 2.423

4.  Measurement of sodium ion concentration in the unstirred layer of rat small intestine by polymer Na+-sensitive electrodes.

Authors:  M L Lucas; M J Cannon
Journal:  Biochim Biophys Acta       Date:  1983-04-21

5.  Neutral carrier based hydrogen ion selective microelectrode for extra- and intracellular studies.

Authors:  D Ammann; F Lanter; R A Steiner; P Schulthess; Y Shijo; W Simon
Journal:  Anal Chem       Date:  1981-12       Impact factor: 6.986

  5 in total
  3 in total

1.  The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

Authors:  P Duroux; C Emde; P Bauerfeind; C Francis; A Grisel; L Thybaud; D Arstrong; C Depeursinge; A L Blum
Journal:  Gut       Date:  1991-03       Impact factor: 23.059

2.  Solvent polymeric membrane pH catheter electrode for intraluminal measurements in the upper gastrointestinal tract.

Authors:  U Oesch; Z Brzózka; A Xu; W Simon
Journal:  Med Biol Eng Comput       Date:  1987-07       Impact factor: 2.602

Review 3.  Technical aspects of intraluminal pH-metry in man: current status and recommendations.

Authors:  C Emde; A Garner; A L Blum
Journal:  Gut       Date:  1987-09       Impact factor: 23.059

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.