Fumihiro Ohchi1, Nobuyasu Komasawa2, Kentaro Imagawa1, Kaori Okamoto1, Toshiaki Minami1. 1. Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka, 569-8686, Japan. 2. Department of Anesthesiology, Osaka Medical College, Daigaku-machi 2-7, Takatsuki, Osaka, 569-8686, Japan. ane078@poh.osaka-med.ac.jp.
Abstract
PURPOSE: During out-of-hospital cardiopulmonary resuscitation, several factors can render tracheal intubation more difficult, such as when rescuers must secure the airway in complete darkness or with limited illumination. The purpose of this study was to evaluate the efficacy of six supraglottic devices (SGDs), ProSeal(®) (ProSeal), Classic(®) (Classic), Supreme(®) (Supreme), Laryngeal Tube(®) (LT), air-Q(®) (air-Q), and i-gel(®) (i-gel), for airway management under light and dark conditions using a manikin. METHODS:Seventeen novice doctors and 15 experienced doctors performed insertion of six SGDs under light and dark conditions using an adult manikin. Insertion time, successful ventilation rate, and subjective insertion difficulty on a visual analogue scale (VAS) were measured. RESULTS: Both novice and experienced doctors had a significantly lower ventilation success rate in the dark than in the light when ProSeal and Classic were used, but not with the other four SGDs. Novice doctors required a significantly longer insertion time in the dark than in the light with all SGDs. Experienced doctors required a significantly longer insertion time in the dark than in the light with ProSeal or Classic, but not with the other four SGDs. VAS was significantly higher for both novice and experienced doctors when ProSeal and Classic were used, as compared with the other four SGDs in the dark. CONCLUSIONS: Compared to ProSeal and Classic, Supreme, i-gel, LT, and air-Q are more effective for airway management in the dark. Our findings suggest that anatomically shaped SGDs may help novice doctors secure the airway under dark conditions.
RCT Entities:
PURPOSE: During out-of-hospital cardiopulmonary resuscitation, several factors can render tracheal intubation more difficult, such as when rescuers must secure the airway in complete darkness or with limited illumination. The purpose of this study was to evaluate the efficacy of six supraglottic devices (SGDs), ProSeal(®) (ProSeal), Classic(®) (Classic), Supreme(®) (Supreme), Laryngeal Tube(®) (LT), air-Q(®) (air-Q), and i-gel(®) (i-gel), for airway management under light and dark conditions using a manikin. METHODS: Seventeen novice doctors and 15 experienced doctors performed insertion of six SGDs under light and dark conditions using an adult manikin. Insertion time, successful ventilation rate, and subjective insertion difficulty on a visual analogue scale (VAS) were measured. RESULTS: Both novice and experienced doctors had a significantly lower ventilation success rate in the dark than in the light when ProSeal and Classic were used, but not with the other four SGDs. Novice doctors required a significantly longer insertion time in the dark than in the light with all SGDs. Experienced doctors required a significantly longer insertion time in the dark than in the light with ProSeal or Classic, but not with the other four SGDs. VAS was significantly higher for both novice and experienced doctors when ProSeal and Classic were used, as compared with the other four SGDs in the dark. CONCLUSIONS: Compared to ProSeal and Classic, Supreme, i-gel, LT, and air-Q are more effective for airway management in the dark. Our findings suggest that anatomically shaped SGDs may help novice doctors secure the airway under dark conditions.
Authors: Lorenz G Theiler; Maren Kleine-Brueggeney; Dagmar Kaiser; Natalie Urwyler; Cedric Luyet; Andreas Vogt; Robert Greif; M M E Unibe Journal: Anesthesiology Date: 2009-07 Impact factor: 7.892