Literature DB >> 26206177

Evaluation of the efficacy of six supraglottic devices for airway management in dark conditions: a crossover randomized simulation trial.

Fumihiro Ohchi1, Nobuyasu Komasawa2, Kentaro Imagawa1, Kaori Okamoto1, Toshiaki Minami1.   

Abstract

PURPOSE: During out-of-hospital cardiopulmonary resuscitation, several factors can render tracheal intubation more difficult, such as when rescuers must secure the airway in complete darkness or with limited illumination. The purpose of this study was to evaluate the efficacy of six supraglottic devices (SGDs), ProSeal(®) (ProSeal), Classic(®) (Classic), Supreme(®) (Supreme), Laryngeal Tube(®) (LT), air-Q(®) (air-Q), and i-gel(®) (i-gel), for airway management under light and dark conditions using a manikin.
METHODS: Seventeen novice doctors and 15 experienced doctors performed insertion of six SGDs under light and dark conditions using an adult manikin. Insertion time, successful ventilation rate, and subjective insertion difficulty on a visual analogue scale (VAS) were measured.
RESULTS: Both novice and experienced doctors had a significantly lower ventilation success rate in the dark than in the light when ProSeal and Classic were used, but not with the other four SGDs. Novice doctors required a significantly longer insertion time in the dark than in the light with all SGDs. Experienced doctors required a significantly longer insertion time in the dark than in the light with ProSeal or Classic, but not with the other four SGDs. VAS was significantly higher for both novice and experienced doctors when ProSeal and Classic were used, as compared with the other four SGDs in the dark.
CONCLUSIONS: Compared to ProSeal and Classic, Supreme, i-gel, LT, and air-Q are more effective for airway management in the dark. Our findings suggest that anatomically shaped SGDs may help novice doctors secure the airway under dark conditions.

Keywords:  Dark; Experienced doctor; Manikin; Novice doctor; Supraglottic devices

Mesh:

Year:  2015        PMID: 26206177     DOI: 10.1007/s00540-015-2050-8

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  23 in total

1.  Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation.

Authors:  T M Cook; B McCormick; T Asai
Journal:  Br J Anaesth       Date:  2003-09       Impact factor: 9.166

Review 2.  Supraglottic airways in difficult airway management: successes, failures, use and misuse.

Authors:  A Timmermann
Journal:  Anaesthesia       Date:  2011-12       Impact factor: 6.955

3.  Comparison of Supreme(®) and Soft Seal(®) laryngeal masks for airway management during cardiopulmonary resuscitation in novice doctors: a manikin study.

Authors:  Hanako Kohama; Nobuyasu Komasawa; Ryusuke Ueki; Aoi Samma; Masashi Nakagawa; Shin-ichi Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-12-01       Impact factor: 2.078

4.  Comparison of air-Q(®) and Soft Seal(®) laryngeal mask for airway management by novice doctors during infant chest compression: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Noriyasu Yamamoto; Kazuaki Atagi; Shin-ichi Nishi; Yoshiroh Kaminoh; Chikara Tashiro
Journal:  Resuscitation       Date:  2011-09-28       Impact factor: 5.262

5.  Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin.

Authors:  T Asai
Journal:  Anaesthesia       Date:  2009-10       Impact factor: 6.955

6.  Comparison of Laryngeal Mask Supreme® and Soft Seal® for airway management in several positions.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Akari Fujii; Aoi Samma; Masashi Nakagawa; Shin-ich Nishi; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2011-04-12       Impact factor: 2.078

7.  Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study.

Authors:  Nobuyasu Komasawa; Ryusuke Ueki; Hajime Nomura; Motoi Itani; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2010-02-03       Impact factor: 2.078

8.  Comparison of tube-guided and guideless videolaryngoscope for tracheal intubation during chest compression in a manikin: a randomized crossover trial.

Authors:  Daisuke Okada; Nobuyasu Komasawa; Shunsuke Fujiwara; Toshiaki Minami
Journal:  J Anesth       Date:  2014-10-28       Impact factor: 2.078

9.  Prewarming of the i-gel facilitates successful insertion and ventilation efficacy with muscle relaxation: a randomized study.

Authors:  Nobuyasu Komasawa; Isao Nishihara; Shinichi Tatsumi; Toshiaki Minami
Journal:  J Clin Anesth       Date:  2014-11-18       Impact factor: 9.452

10.  Crossover comparison of the laryngeal mask supreme and the i-gel in simulated difficult airway scenario in anesthetized patients.

Authors:  Lorenz G Theiler; Maren Kleine-Brueggeney; Dagmar Kaiser; Natalie Urwyler; Cedric Luyet; Andreas Vogt; Robert Greif; M M E Unibe
Journal:  Anesthesiology       Date:  2009-07       Impact factor: 7.892

View more
  1 in total

1.  A prospective observational study comparing two supraglottic airway devices in out-of-hospital cardiac arrest.

Authors:  Maja Pålsdatter Lønvik; Odd Eirik Elden; Mats Joakimsen Lunde; Trond Nordseth; Karin Elvenes Bakkelund; Oddvar Uleberg
Journal:  BMC Emerg Med       Date:  2021-04-20
  1 in total