Literature DB >> 11038009

Accuracy of 131I tumor quantification in radioimmunotherapy using SPECT imaging with an ultra-high-energy collimator: Monte Carlo study.

Y K Dewaraja1, M Ljungberg, K F Koral.   

Abstract

UNLABELLED: Accuracy of 131I tumor quantification after radioimmunotherapy (RIT) was investigated for SPECT imaging with an ultra-high-energy (UHE) collimator designed for imaging 511-keV photons.
METHODS: First, measurements and Monte Carlo simulations were carried out to compare the UHE collimator with a conventionally used, high-energy collimator. On the basis of this comparison, the UHE collimator was selected for this investigation, which was carried out by simulation of spherical tumors in a phantom. Reconstruction was by an expectation-maximization algorithm that included scatter and attenuation correction. Keeping the tumor activity constant, simulations were carried out to assess how volume-of-interest (VOI) counts vary with background activity, radius of rotation (ROR), tumor location, and size. The constant calibration factor for quantification was determined from VOI counts corresponding to a 3.63-cm-radius sphere of known activity. Tight VOIs corresponding to the physical size of the spheres or tumors were used.
RESULTS: Use of the UHE collimator resulted in a large reduction in 131I penetration, which is especially significant in RIT where background uptake is high. With the UHE collimator, typical patient images showed an improvement in contrast. Considering the desired geometric events, sensitivity was reduced, but only by a factor of 1.6. Simulation results for a 3.63-cm-radius tumor showed that VOI counts vary with background, location, and ROR by less than 3.2%, 3%, and 5.3%, respectively. The variation with tumor size was more significant and was a function of the background. Good quantification accuracy (<6.5% error) was achieved when tumor size was the same as the sphere size used in the calibration, irrespective of the other parameters. For smaller tumors, activities were underestimated by up to -15% for the 2.88-cm-radius sphere, -23% for the 2.29-cm-radius sphere, and -47% for the 1.68-cm-radius sphere.
CONCLUSION: Reasonable accuracy can be achieved for VOI quantification of 131I using SPECT with an UHE collimator and a constant calibration factor. Difference in tumor size relative to the size of the calibration sphere had the biggest effect on accuracy, and recovery coefficients are needed to improve quantification of small tumors.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11038009      PMCID: PMC2812013     

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  23 in total

1.  SCINTILLATION CAMERA WITH MULTICHANNEL COLLIMATORS.

Authors:  H O ANGER
Journal:  J Nucl Med       Date:  1964-07       Impact factor: 10.057

2.  Development and validation of a Monte Carlo simulation of photon transport in an Anger camera.

Authors:  D J De Vries; S C Moore; R E Zimmerman; S P Mueller; B Friedland; R C Lanza
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

3.  Quantitative imaging of iodine-131 distributions in brain tumors with pinhole SPECT: a phantom study.

Authors:  M F Smith; D R Gilland; R E Coleman; R J Jaszczak
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

4.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

5.  Improved conjugate view quantitation of I-131 by subtraction of scatter and septal penetration events with a triple energy window method.

Authors:  D J Macey; E J Grant; J E Bayouth; H B Giap; S J Danna; R Sirisriro; D A Podoloff
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

6.  CT-SPECT fusion plus conjugate views for determining dosimetry in iodine-131-monoclonal antibody therapy of lymphoma patients.

Authors:  K F Koral; K R Zasadny; M L Kessler; J Q Luo; S F Buchbinder; M S Kaminski; I Francis; R L Wahl
Journal:  J Nucl Med       Date:  1994-10       Impact factor: 10.057

7.  Preliminary validation of the opposing view method for quantitative gamma camera imaging.

Authors:  J F Eary; F L Appelbaum; L Durack; P Brown
Journal:  Med Phys       Date:  1989 May-Jun       Impact factor: 4.071

8.  Increased survival associated with radiolabeled Lym-1 therapy for non-Hodgkin's lymphoma and chronic lymphocytic leukemia.

Authors:  G L DeNardo; K R Lamborn; D S Goldstein; L A Kroger; S J DeNardo
Journal:  Cancer       Date:  1997-12-15       Impact factor: 6.860

9.  Quantitation in positron emission computed tomography: 5. Physical--anatomical effects.

Authors:  J C Mazziotta; M E Phelps; D Plummer; D E Kuhl
Journal:  J Comput Assist Tomogr       Date:  1981-10       Impact factor: 1.826

10.  Phase II trial of 131I-B1 (anti-CD20) antibody therapy with autologous stem cell transplantation for relapsed B cell lymphomas.

Authors:  O W Press; J F Eary; F R Appelbaum; P J Martin; W B Nelp; S Glenn; D R Fisher; B Porter; D C Matthews; T Gooley
Journal:  Lancet       Date:  1995-08-05       Impact factor: 79.321

View more
  8 in total

1.  A parallel Monte Carlo code for planar and SPECT imaging: implementation, verification and applications in (131)I SPECT.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Amitava Majumdar; Abhijit Bose; Kenneth F Koral
Journal:  Comput Methods Programs Biomed       Date:  2002-02       Impact factor: 5.428

2.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

3.  Comparison of residence time estimation methods for radioimmunotherapy dosimetry and treatment planning--Monte Carlo simulation studies.

Authors:  B He; R L Wahl; Y Du; G Sgouros; H Jacene; I Flinn; E C Frey
Journal:  IEEE Trans Med Imaging       Date:  2008-04       Impact factor: 10.048

4.  SIMIND Monte Carlo simulation of a single photon emission CT.

Authors:  M T Bahreyni Toossi; J Pirayesh Islamian; M Momennezhad; M Ljungberg; S H Naseri
Journal:  J Med Phys       Date:  2010-01

5.  Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification.

Authors:  Y K Dewaraja; M Ljungberg; K F Koral
Journal:  Eur J Nucl Med       Date:  2001-07

6.  Accurate dosimetry in 131I radionuclide therapy using patient-specific, 3-dimensional methods for SPECT reconstruction and absorbed dose calculation.

Authors:  Yuni K Dewaraja; Scott J Wilderman; Michael Ljungberg; Kenneth F Koral; Kenneth Zasadny; Mark S Kaminiski
Journal:  J Nucl Med       Date:  2005-05       Impact factor: 10.057

Review 7.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

8.  Simultaneous SPECT imaging of multi-targets to assist in identifying hepatic lesions.

Authors:  Zhide Guo; Mengna Gao; Deliang Zhang; Yesen Li; Manli Song; Rongqiang Zhuang; Xinhui Su; Guibing Chen; Ting Liu; Pingguo Liu; Hua Wu; Jin Du; Xianzhong Zhang
Journal:  Sci Rep       Date:  2016-07-05       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.