Improved activity estimation with MC-JOSEM versus TEW-JOSEM in 111In SPECT.

Jinsong Ouyang1, Georges El Fakhri, Stephen C Moore.   

Abstract

We have previously developed a fast Monte Carlo (MC)-based joint ordered-subset expectation maximization (JOSEM) iterative reconstruction algorithm, MC-JOSEM. A phantom study was performed to compare quantitative imaging performance of MC-JOSEM with that of a triple-energy-window approach (TEW) in which estimated scatter was also included additively within JOSEM, TEW-JOSEM. We acquired high-count projections of a 5.5 cm3 sphere of 111In at different locations in the water-filled torso phantom; high-count projections were then obtained with 111In only in the liver or only in the soft-tissue background compartment, so that we could generate synthetic projections for spheres surrounded by various activity distributions. MC scatter estimates used by MC-JOSEM were computed once after five iterations of TEW-JOSEM. Images of different combinations of liver/background and sphere/background activity concentration ratios were reconstructed by both TEW-JOSEM and MC-JOSEM for 40 iterations. For activity estimation in the sphere, MC-JOSEM always produced better relative bias and relative standard deviation than TEW-JOSEM for each sphere location, iteration number, and activity combination. The average relative bias of activity estimates in the sphere for MC-JOSEM after 40 iterations was -6.9%, versus -15.8% for TEW-JOSEM, while the average relative standard deviation of the sphere activity estimates was 16.1% for MC-JOSEM, versus 27.4% for TEW-JOSEM. Additionally, the average relative bias of activity concentration estimates in the liver and the background for MC-JOSEM after 40 iterations was -3.9%, versus -12.2% for TEW-JOSEM, while the average relative standard deviation of these estimates was 2.5% for MC-JOSEM, versus 3.4% for TEW-JOSEM. MC-JOSEM is a promising approach for quantitative activity estimation in 111In SPECT.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18561679      PMCID: PMC2673642          DOI: 10.1118/1.2907561

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Rapid SPECT simulation of downscatter in non-uniform media.

Authors:  H W de Jong; F J Beekman
Journal:  Phys Med Biol       Date:  2001-03       Impact factor: 3.609

2.  Efficient simulation of SPECT down-scatter including photon interactions with crystal and lead.

Authors:  Hugo W A M de Jong; Wen-Tung Wang; Eric C Frey; Max A Viergever; Freek J Beekman
Journal:  Med Phys       Date:  2002-04       Impact factor: 4.071

Review 3.  Scatter modelling and compensation in emission tomography.

Authors:  Habib Zaidi; Kenneth F Koral
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-31       Impact factor: 9.236

4.  Quantitative SPECT for indium-111-labeled antibodies in the livers of beagle dogs.

Authors:  P K Leichner; H M Vriesendorp; W G Hawkins; S M Quadri; N C Yang; R L Stinson; D M Loudenslager; T L Frankel; X Y Chen; J L Klein
Journal:  J Nucl Med       Date:  1991-07       Impact factor: 10.057

5.  A Monte Carlo and physical phantom evaluation of quantitative In-111 SPECT.

Authors:  Bin He; Yong Du; Xiyun Song; W Paul Segars; Eric C Frey
Journal:  Phys Med Biol       Date:  2005-08-24       Impact factor: 3.609

6.  A practical method for position-dependent Compton-scatter correction in single photon emission CT.

Authors:  K Ogawa; Y Harata; T Ichihara; A Kubo; S Hashimoto
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

7.  3-D Monte Carlo-Based Scatter Compensation in Quantitative I-131 SPECT Reconstruction.

Authors:  Yuni K Dewaraja; Michael Ljungberg; Jeffrey A Fessler
Journal:  IEEE Trans Nucl Sci       Date:  2006       Impact factor: 1.679

8.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

9.  Fast Monte Carlo based joint iterative reconstruction for simultaneous 99mTc/ 123I SPECT imaging.

Authors:  Jinsong Ouyang; Georges El Fakhri; Stephen C Moore
Journal:  Med Phys       Date:  2007-08       Impact factor: 4.071

  9 in total
  4 in total

1.  MIRD pamphlet No. 23: quantitative SPECT for patient-specific 3-dimensional dosimetry in internal radionuclide therapy.

Authors:  Yuni K Dewaraja; Eric C Frey; George Sgouros; A Bertrand Brill; Peter Roberson; Pat B Zanzonico; Michael Ljungberg
Journal:  J Nucl Med       Date:  2012-06-28       Impact factor: 10.057

2.  Evaluation of a method for projection-based tissue-activity estimation within small volumes of interest.

Authors:  Sudeepti Southekal; Sarah J McQuaid; Marie Foley Kijewski; Stephen C Moore
Journal:  Phys Med Biol       Date:  2012-01-13       Impact factor: 3.609

3.  Quantitative simultaneous 99mTc/123I cardiac SPECT using MC-JOSEM.

Authors:  Jinsong Ouyang; Xuping Zhu; Cathryn M Trott; Georges El Fakhri
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

4.  Quantitative simultaneous 111In∕99mTc SPECT-CT of osteomyelitis.

Authors:  Morgan Cervo; Victor H Gerbaudo; Mi-Ae Park; Stephen C Moore
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.