Static Versus Dynamic Teboroxime Myocardial Perfusion SPECT in Canines.

D J Kadrmas1, E V R Di Bella, H S Khare, P E Christian, G T Gullberg.   

Abstract

Tc-99m-teboroxime is a perfusion tracer with high myocardial extraction, fast washin and washout kinetics, and excellent imaging properties. The fast kinetics pose some problems for static imaging, but they also allow for back-to-back stress / rest studies to be performed very quickly. Furthermore, such fast kinetics are ideally suited for dynamic imaging. We have compared static versus dynamic myocardial perfusion SPECT with teboroxime in canines using microsphere-derived flow values as the gold standard. Dynamic data were successfully acquired at rest and under adenosine stress in seven dogs using a fast serial scanning protocol. The data were analyzed in two ways: summing timeframes to create a single, static dataset with consistent projections; and 4D reconstruction and kinetic parameter estimation for a two compartment model. In both cases imaging data (voxel intensity or washin rate parameter) were correlated with flow values measured by microspheres. The static summing procedure that produced the best correlation with flow consisted of summing the projection data acquired from 60 to 180 seconds post-injection. The washin rate parameter was found to provide better correlation with flow than static image intensity in six of seven animals. When the data were pooled over all studies, washin provided significantly better correlation with flow than static imaging (p<0.01). We conclude that dynamic imaging of teboroxime with compartmental modeling provides a better measure of flow than can be obtained from static imaging techniques.

Entities:  

Year:  2000        PMID: 20090867      PMCID: PMC2808143          DOI: 10.1109/23.856556

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  18 in total

1.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

2.  Blood flow measurements with radionuclide-labeled particles.

Authors:  M A Heymann; B D Payne; J I Hoffman; A M Rudolph
Journal:  Prog Cardiovasc Dis       Date:  1977 Jul-Aug       Impact factor: 8.194

3.  Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow.

Authors:  R E Stewart; M Schwaiger; G D Hutchins; P C Chiao; K P Gallagher; N Nguyen; N A Petry; W L Rogers
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

4.  Kinetic data analysis with a noisy input function.

Authors:  R H Huesman; B M Mazoyer
Journal:  Phys Med Biol       Date:  1987-12       Impact factor: 3.609

5.  EM reconstruction algorithms for emission and transmission tomography.

Authors:  K Lange; R Carson
Journal:  J Comput Assist Tomogr       Date:  1984-04       Impact factor: 1.826

6.  A neutral technetium-99m complex for myocardial imaging.

Authors:  R K Narra; A D Nunn; B L Kuczynski; T Feld; P Wedeking; W C Eckelman
Journal:  J Nucl Med       Date:  1989-11       Impact factor: 10.057

7.  Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera.

Authors:  T Chua; H Kiat; G Germano; K Takemoto; G Fernandez; Y Biasio; J Friedman; D Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

8.  Rapid redistribution of teboroxime.

Authors:  H Weinstein; S T Dahlberg; B A McSherry; R C Hendel; J A Leppo
Journal:  Am J Cardiol       Date:  1993-04-01       Impact factor: 2.778

9.  Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model.

Authors:  A M Smith; G T Gullberg; P E Christian; F L Datz
Journal:  J Nucl Med       Date:  1994-03       Impact factor: 10.057

Review 10.  A review of cardiac imaging with sestamibi and teboroxime.

Authors:  J A Leppo; E G DePuey; L L Johnson
Journal:  J Nucl Med       Date:  1991-10       Impact factor: 10.057

View more
  5 in total

1.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

2.  Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: comparison with static thallium-201 in a canine model.

Authors:  E V Di Bella; S G Ross; D J Kadrmas; H S Khare; P E Christian; S McJames; A G Gullberg
Journal:  Invest Radiol       Date:  2001-03       Impact factor: 6.016

3.  Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study.

Authors:  Simona Ben-Haim; Venkatesh L Murthy; Christopher Breault; Rayjanah Allie; Arkadiusz Sitek; Nathaniel Roth; Jolene Fantony; Stephen C Moore; Mi-Ae Park; Marie Kijewski; Athar Haroon; Piotr Slomka; Kjell Erlandsson; Rafael Baavour; Yoel Zilberstien; Jamshed Bomanji; Marcelo F Di Carli
Journal:  J Nucl Med       Date:  2013-04-11       Impact factor: 10.057

4.  Comparison of Static and Dynamic Cardiac Perfusion Thallium-201 SPECT.

Authors:  Harshali S Khare; Edward V R Dibella; Dan J Kadrmas; Paul E Christian; Grant T Gullberg
Journal:  IEEE Trans Nucl Sci       Date:  2001-06       Impact factor: 1.679

5.  Effects of the attenuation correction and reconstruction method parameters on conventional cardiac dynamic SPECT.

Authors:  Mohammadreza Mohseni; Reza Faghihi; Mahdi Haghighatafshar; Seyed Mohammad Entezarmahdi
Journal:  Medicine (Baltimore)       Date:  2018-09       Impact factor: 1.889

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.