Literature DB >> 8113904

Kinetic modeling of teboroxime using dynamic SPECT imaging of a canine model.

A M Smith1, G T Gullberg, P E Christian, F L Datz.   

Abstract

UNLABELLED: The tomographic utility of 99mTc-labeled teboroxime has been limited because of its fast washout from the heart, which requires rapid data acquisitions that have not been feasible until the recent development of multidetector SPECT systems.
METHODS: Using a three-detector SPECT system to acquire dynamic tomographic data every 10.2 sec, we investigated the potential of modeling the kinetics of teboroxime to develop a sensitive and quantitative measure of cardiac perfusion. Seven studies were performed on four dogs; in three of the studies the LAD artery was occluded. The three-dimensional activity distributions were reconstructed and were corrected for attenuation using a transmission scan. Time-activity curves from the blood and tissue were fit to a two-compartment model with two-way exchange.
RESULTS: Performing attenuation correction during the reconstruction process affected the washin parameter k21 significantly (p < 0.0001). The washin parameter k21 also decreased significantly (p < 0.002) when the LAD was occluded.
CONCLUSIONS: The results indicate that the washin of teboroxime in myocardial tissue (k21) measured using dynamic SPECT imaging and kinetic modeling is an indicator of myocardial blood flow.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8113904

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  19 in total

1.  Analytical propagation of errors in dynamic SPECT: estimators, degrading factors, bias and noise.

Authors:  D J Kadrmas; E V DiBella; R H Huesman; G T Gullberg
Journal:  Phys Med Biol       Date:  1999-08       Impact factor: 3.609

2.  Technetium 99m-N-NOET: although not equivalent to thallium-201, it still offers new opportunities.

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  2000 Mar-Apr       Impact factor: 5.952

Review 3.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

4.  Global Compartmental Pharmacokinetic Models for Spatiotemporal SPECT and PET Imaging.

Authors:  Eric Clarkson; Matthew A Kupinski
Journal:  SIAM J Imaging Sci       Date:  2009-01       Impact factor: 2.867

5.  Assessment of myocardial perfusion with Tc-99m: image is everything.

Authors:  Seth T Dahlberg
Journal:  J Nucl Cardiol       Date:  2009-04-30       Impact factor: 5.952

6.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

7.  Experimental verification of technetium 99m-labeled teboroxime kinetic parameters in the myocardium with dynamic single-photon emission computed tomography: reproducibility, correlation to flow, and susceptibility to extravascular contamination.

Authors:  A M Smith; G T Gullberg; P E Christian
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

8.  Assessment of reperfusion after acute myocardial infarction: is there a role for acute technetium 99m-teboroxime imaging?

Authors:  A J Sinusas
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

Review 9.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

Review 10.  What is the current status of quantification and nuclear medicine in cardiology?

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1996-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.