UNLABELLED: Di Bella EVR, Ross SG, Kadrmas DJ, et al. Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: Comparison with static thallium-201 in a canine model. Invest Radiol 2001;36:178-185. RATIONALE AND
OBJECTIVES: A compartmental modeling approach to deriving kinetic parameters from a time series of single-photon emission computed tomography (SPECT) images of technetium-99m-labeled (99mTc-) teboroxime may have value for semiquantitative assessment of myocardial perfusion. This study investigated the value of the kinetic parameters derived from a two-compartment model of 99mTc-teboroxime for measuring myocardial perfusion and compared it with static thallium-201 (201Tl) uptake and microsphere-measured blood flow in dogs.
METHODS: Experiments were successfully conducted in 9 of 11 open-chest dogs. During adenosine stress, a single complete set of projections of 201Tl uptake was acquired. 99mTc-teboroxime was then injected during adenosine stress, and a complete set of projections was acquired every 5.7 seconds for 17 minutes. Resting studies were performed on 4 of the animals. All of the projection sets were reconstructed with an iterative algorithm and incorporated corrections for attenuation and the geometric response of the collimators. Regional kinetic parameters (washin and washout) were determined semiautomatically from the time series of reconstructed 99mTc-teboroxime images and registered with microsphere data. Regional washin estimates were compared with 201Tl intensities and myocardial blood flows determined from microspheres.
RESULTS: Optimally scaled 99mTc-teboroxime washin parameters and 201Tl uptakes were correlated with microsphere-determined blood flows (r = 0.91, y = 0. 99x + 0.01, and r = 0.92, y = 0.88x + 0.28, respectively). In six of the studies, the left anterior descending coronary artery was occluded, and stress occluded-to-normal (O/N) ratios were calculated. The O/N ratios were 0.32 +/- 0.17 as determined from microspheres injected with 201Tl and 0.38 +/- 0.29 from microspheres injected with 99mTc-teboroxime (P = NS). The O/N ratios were 0.48 +/- 0.16 for static 201Tl uptake and 0.27 +/- 0.21 for 99mTc-teboroxime washin (P < 0.05).
CONCLUSIONS: Both 201Tl uptake and 99mTc-teboroxime kinetic parameters were well correlated with flow. The 99mTc-teboroxime washin parameters offer semiquantitative flow values and provide greater defect contrast than can be obtained with 201Tl uptake values.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11228582      PMCID: PMC2818759          DOI: 10.1097/00004424-200103000-00007

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  22 in total

1.  Myocardial clearance kinetics of technetium-99m-SQ30217: a marker of regional myocardial blood flow.

Authors:  R E Stewart; M Schwaiger; G D Hutchins; P C Chiao; K P Gallagher; N Nguyen; N A Petry; W L Rogers
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

2.  Preliminary report of SPECT imaging with Tc-99m teboroxime in ischemic heart disease.

Authors:  W E Drane; S Keim; P Strickland; A Tineo; M Nicole
Journal:  Clin Nucl Med       Date:  1992-03       Impact factor: 7.794

3.  Technetium-99m teboroxime scintigraphy. Clinical experience in patients referred for myocardial perfusion evaluation.

Authors:  L Bontemps; X Geronicola-Trapali; Y Sayegh; O Delmas; R Itti; X André-Fouët
Journal:  Eur J Nucl Med       Date:  1991

4.  Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera.

Authors:  T Chua; H Kiat; G Germano; K Takemoto; G Fernandez; Y Biasio; J Friedman; D Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

5.  Teboroxime, sestamibi and thallium-201 as markers of myocardial hypoperfusion: comparison by quantitative dual-isotope autoradiography in rabbits.

Authors:  H Weinstein; C P Reinhardt; J A Leppo
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

6.  Static Versus Dynamic Teboroxime Myocardial Perfusion SPECT in Canines.

Authors:  D J Kadrmas; E V R Di Bella; H S Khare; P E Christian; G T Gullberg
Journal:  IEEE Trans Nucl Sci       Date:  2000-06-01       Impact factor: 1.679

7.  Myocardial extraction of teboroxime: effects of teboroxime interaction with blood.

Authors:  W L Rumsey; K C Rosenspire; A D Nunn
Journal:  J Nucl Med       Date:  1992-01       Impact factor: 10.057

8.  Comparison between thallium-201, technetium-99m-sestamibi and technetium-99m-teboroxime planar myocardial perfusion imaging in detection of coronary artery disease.

Authors:  R Taillefer; R Lambert; R Essiambre; D C Phaneuf; J Léveillé
Journal:  J Nucl Med       Date:  1992-06       Impact factor: 10.057

9.  Myocardial technetium-99m-teboroxime uptake during adenosine-induced hyperemia in dogs with either a critical or mild coronary stenosis: comparison to thallium-201 and regional blood flow.

Authors:  D K Glover; M Ruiz; E E Bergmann; J P Simanis; W H Smith; D D Watson; G A Beller
Journal:  J Nucl Med       Date:  1995-03       Impact factor: 10.057

10.  Technetium-99m teboroxime regional myocardial washout in subjects with and without coronary artery disease.

Authors:  T Chua; H Kiat; G Germano; W Palmas; K Takemoto; J Friedman; D S Berman
Journal:  Am J Cardiol       Date:  1993-09-15       Impact factor: 2.778

View more
  15 in total

1.  Estimation of coronary flow reserve: can SPECT compete with other modalities?

Authors:  G T Gullberg; E V Di Bella; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  Detectability of perfusion defect in five-dimensional gated-dynamic cardiac SPECT images.

Authors:  Xiaofeng Niu; Yongyi Yang; Michael A King; Miles N Wernick
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

4.  Simultaneous assessment of cardiac perfusion and function using 5-dimensional imaging with Tc-99m teboroxime.

Authors:  Bing Feng; P Hendrik Pretorius; Troy H Farncombe; Seth T Dahlberg; Manoj V Narayanan; Miles N Wernick; Anna M Celler; Jeffrey A Leppo; Michael A King
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

Review 5.  Methodology for quantifying absolute myocardial perfusion with PET and SPECT.

Authors:  Martin A Lodge; Frank M Bengel
Journal:  Curr Cardiol Rep       Date:  2007-04       Impact factor: 2.931

6.  Fast direct estimation of the blood input function and myocardial time activity curve from dynamic SPECT projections via reduction in spatial and temporal dimensions.

Authors:  Yunlong Zan; Rostyslav Boutchko; Qiu Huang; Biao Li; Kewei Chen; Grant T Gullberg
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

7.  Dynamic SPECT: evolution of a widely available tool for the assessment of coronary flow reserve.

Authors:  Simona Ben-Haim; Denis Agostini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02       Impact factor: 9.236

8.  Myocardial blood flow quantification with SPECT and conventional tracers: a critical appraisal.

Authors:  Stephan G Nekolla; Christoph Rischpler; Kenichi Nakajima
Journal:  J Nucl Cardiol       Date:  2014-10-04       Impact factor: 5.952

9.  Are SPECT measurements of myocardial blood flow and flow reserve ready for clinical use?

Authors:  Ernest V Garcia
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-12       Impact factor: 9.236

10.  Quantitation of myocardial blood flow and myocardial flow reserve with 99mTc-sestamibi dynamic SPECT/CT to enhance detection of coronary artery disease.

Authors:  Bailing Hsu; Fu-Chung Chen; Tao-Cheng Wu; Wen-Sheng Huang; Po-Nien Hou; Chien-Cheng Chen; Guang-Uei Hung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-08-21       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.