Literature DB >> 23578996

Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study.

Simona Ben-Haim1, Venkatesh L Murthy, Christopher Breault, Rayjanah Allie, Arkadiusz Sitek, Nathaniel Roth, Jolene Fantony, Stephen C Moore, Mi-Ae Park, Marie Kijewski, Athar Haroon, Piotr Slomka, Kjell Erlandsson, Rafael Baavour, Yoel Zilberstien, Jamshed Bomanji, Marcelo F Di Carli.   

Abstract

UNLABELLED: Myocardial perfusion imaging (MPI) is well established in the diagnosis and workup of patients with known or suspected coronary artery disease (CAD); however, it can underestimate the extent of obstructive CAD. Quantification of myocardial perfusion reserve with PET can assist in the diagnosis of multivessel CAD. We evaluated the feasibility of dynamic tomographic SPECT imaging and quantification of a retention index to describe global and regional myocardial perfusion reserve using a dedicated solid-state cardiac camera.
METHODS: Ninety-five consecutive patients (64 men and 31 women; median age, 67 y) underwent dynamic SPECT imaging with (99m)Tc-sestamibi at rest and at peak vasodilator stress, followed by standard gated MPI. The dynamic images were reconstructed into 60-70 frames, 3-6 s/frame, using ordered-subsets expectation maximization with 4 iterations and 32 subsets. Factor analysis was used to estimate blood-pool time-activity curves, used as input functions in a 2-compartment kinetic model. K1 values ((99m)Tc-sestamibi uptake) were calculated for the stress and rest images, and K2 values ((99m)Tc-sestamibi washout) were set to zero. Myocardial perfusion reserve (MPR) index was calculated as the ratio of the stress and rest K1 values. Standard MPI was evaluated semiquantitatively, and total perfusion deficit (TPD) of at least 5% was defined as abnormal.
RESULTS: Global MPR index was higher in patients with normal MPI (n = 51) than in patients with abnormal MPI (1.61 [interquartile range (IQR), 1.33-2.03] vs. 1.27 [IQR, 1.12-1.61], P = 0.0002). By multivariable regression analysis, global MPR index was associated with global stress TPD, age, and smoking. Regional MPR index was associated with the same variables and with regional stress TPD. Sixteen patients undergoing invasive coronary angiography had 20 vessels with stenosis of at least 50%. The MPR index was 1.11 (IQR, 1.01-1.21) versus 1.30 (IQR, 1.12-1.67) in territories supplied by obstructed and nonobstructed arteries, respectively (P = 0.02). MPR index showed a stepwise reduction with increasing extent of obstructive CAD (P = 0.02).
CONCLUSION: Dynamic tomographic imaging and quantification of a retention index describing global and regional perfusion reserve are feasible using a solid-state camera. Preliminary results show that the MPR index is lower in patients with perfusion defects and in regions supplied by obstructed coronary arteries. Further studies are needed to establish the clinical role of this technique as an aid to semiquantitative analysis of MPI.

Entities:  

Keywords:  coronary artery disease; dynamic SPECT; myocardial perfusion imaging; quantification; solid-state camera

Mesh:

Substances:

Year:  2013        PMID: 23578996      PMCID: PMC3951831          DOI: 10.2967/jnumed.112.109652

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  36 in total

Review 1.  Prognostic value of gated myocardial perfusion SPECT.

Authors:  Leslee J Shaw; Ami E Iskandrian
Journal:  J Nucl Cardiol       Date:  2004 Mar-Apr       Impact factor: 5.952

2.  Reduced coronary flow reserve in patients with primary hyperparathyroidism: a study by G-SPECT myocardial perfusion imaging.

Authors:  Cecilia Marini; Massimo Giusti; Riccardo Armonino; Giorgio Ghigliotti; GianPaolo Bezante; Lara Vera; Silvia Morbelli; Elena Pomposelli; Michela Massollo; Patrizia Gandolfo; Francesco Minuto; Gianmario Sambuceti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-04       Impact factor: 9.236

3.  Incremental prognostic value of coronary flow reserve assessed with single-photon emission computed tomography.

Authors:  Stefania Daniele; Carmela Nappi; Wanda Acampa; Giovanni Storto; Teresa Pellegrino; Francesca Ricci; Evgjeni Xhoxhi; Francesco Porcaro; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2011-05-28       Impact factor: 5.952

4.  Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: comparison with the results of intracoronary Doppler technique.

Authors:  Giovanni Storto; Plinio Cirillo; Maria Lucia Eufrasia Vicario; Teresa Pellegrino; Anna Rita Sorrentino; Mario Petretta; Gennaro Galasso; Valerio De Sanctis; Federico Piscione; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

5.  Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin.

Authors:  H Sugihara; Y Yonekura; K Kataoka; D Fukai; N Kitamura; Y Taniguchi
Journal:  J Nucl Cardiol       Date:  2001 Sep-Oct       Impact factor: 5.952

6.  Coronary heart disease in smokers: vitamin C restores coronary microcirculatory function.

Authors:  P A Kaufmann; T Gnecchi-Ruscone; M di Terlizzi; K P Schäfers; T F Lüscher; P G Camici
Journal:  Circulation       Date:  2000-09-12       Impact factor: 29.690

7.  Quantitative upright-supine high-speed SPECT myocardial perfusion imaging for detection of coronary artery disease: correlation with invasive coronary angiography.

Authors:  Ryo Nakazato; Balaji K Tamarappoo; Xingping Kang; Arik Wolak; Faith Kite; Sean W Hayes; Louise E J Thomson; John D Friedman; Daniel S Berman; Piotr J Slomka
Journal:  J Nucl Med       Date:  2010-10-18       Impact factor: 10.057

8.  Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.

Authors:  Hidehiro Iida; Stefan Eberl; Kyeong-Min Kim; Yoshikazu Tamura; Yukihiko Ono; Mayumi Nakazawa; Antti Sohlberg; Tsutomu Zeniya; Takuya Hayashi; Hiroshi Watabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-15       Impact factor: 9.236

9.  Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve.

Authors:  Bernhard A Herzog; Lars Husmann; Ines Valenta; Oliver Gaemperli; Patrick T Siegrist; Fabian M Tay; Nina Burkhard; Christophe A Wyss; Philipp A Kaufmann
Journal:  J Am Coll Cardiol       Date:  2009-07-07       Impact factor: 24.094

10.  Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007.

Authors: 
Journal:  Ann ICRP       Date:  2008
View more
  62 in total

1.  A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

Authors:  Maria Sciammarella; Uttam M Shrestha; Youngho Seo; Grant T Gullberg; Elias H Botvinick
Journal:  J Nucl Cardiol       Date:  2017-08-03       Impact factor: 5.952

2.  Moving ahead with CZT technology.

Authors:  Dominik C Benz; Ronny R Buechel
Journal:  J Nucl Cardiol       Date:  2015-11-10       Impact factor: 5.952

Review 3.  Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Authors:  Roberto Sciagrà; Alessandro Passeri; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Alessia Gimelli; Fabien Hyafil; Denis Agostini; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-02-05       Impact factor: 9.236

4.  Fast direct estimation of the blood input function and myocardial time activity curve from dynamic SPECT projections via reduction in spatial and temporal dimensions.

Authors:  Yunlong Zan; Rostyslav Boutchko; Qiu Huang; Biao Li; Kewei Chen; Grant T Gullberg
Journal:  Med Phys       Date:  2013-09       Impact factor: 4.071

5.  Feasibility of dynamic stress 201Tl/rest 99mTc-tetrofosmin single photon emission computed tomography for quantification of myocardial perfusion reserve in patients with stable coronary artery disease.

Authors:  Sangwon Han; Young-Hak Kim; Jung-Min Ahn; Soo-Jin Kang; Jungsu S Oh; Eonwoo Shin; Changhwan Sung; Sun Young Chae; Seung-Jung Park; Gillan Grimberg; Gil Kovalski; Dae Hyuk Moon
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-06-02       Impact factor: 9.236

6.  Complete and incomplete revascularization: Whose definition is it anyway?

Authors:  Shreenidhi Venuraju; Avijit Lahiri
Journal:  J Nucl Cardiol       Date:  2015-05-20       Impact factor: 5.952

7.  Dynamic SPECT: evolution of a widely available tool for the assessment of coronary flow reserve.

Authors:  Simona Ben-Haim; Denis Agostini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-02       Impact factor: 9.236

8.  Advances in imaging instrumentation for nuclear cardiology.

Authors:  Jae Sung Lee; Gil Kovalski; Tali Sharir; Dong Soo Lee
Journal:  J Nucl Cardiol       Date:  2017-07-17       Impact factor: 5.952

9.  PET should replace SPECT in cardiac imaging for diagnosis and risk assessment of patients with known or suspected CAD: Pro.

Authors:  Jamshid Maddahi; René R Sevag Packard
Journal:  J Nucl Cardiol       Date:  2017-04-10       Impact factor: 5.952

10.  Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera.

Authors:  Cecilia Hindorf; Jenny Oddstig; Fredrik Hedeer; Magnus J Hansson; Jonas Jögi; Henrik Engblom
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.