Literature DB >> 20057012

Effective dose analysis of three-dimensional rotational angiography during catheter ablation procedures.

J-Y Wielandts1, K Smans, J Ector, S De Buck, H Heidbüchel, H Bosmans.   

Abstract

There is increasing use of three-dimensional rotational angiography (3DRA) during cardiac ablation procedures. As compared with 2D angiography, a large series of images are acquired, creating the potential for high radiation doses. The aim of the present study was to quantify patient-specific effective doses. In this study, we developed a computer model to accurately calculate organ doses and the effective dose incurred during 3DRA image acquisition. The computer model simulates the exposure geometry and uses the actual exposure parameters, including the variation in tube voltage and current that is realized through the automatic exposure control (AEC). We performed 3DRA dose calculations in 42 patients referred for ablation on the Siemens Axiom Artis DynaCT system (Erlangen, Germany). Organ doses and effective dose were calculated separately for all projections in the course of the C-arm rotation. The influence of patient body mass index (BMI), dose-area product (DAP), collimation and dose per frame (DPF) rate setting on the calculated doses was also analysed. The effective dose was found to be 5.5 +/- 1.4 mSv according to ICRP 60 and 6.6 +/- 1.8 mSv according to ICRP 103. Effective dose showed an inversely proportional relationship to BMI, while DAP was nearly BMI independent. No simple conversion coefficient between DAP and effective dose could be derived. DPF reduction did not result in a proportional effective dose decrease. These paradoxical findings were explained by the settings of the AEC and the limitations of the x-ray tube. Collimation reduced the effective dose by more than 20%. Three-dimensional rotational angiography is associated with a definite but acceptable radiation dose that can be calculated for all patients separately. Their BMI is a predictor of the effective dose. The dose reduction achieved with collimation suggests that its use is imperative during the 3DRA procedure.

Entities:  

Mesh:

Year:  2010        PMID: 20057012     DOI: 10.1088/0031-9155/55/3/001

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Contrast-Enhanced C-arm Computed Tomography Imaging of Myocardial Infarction in the Interventional Suite.

Authors:  Erin E Girard; Amin Al-Ahmad; Jarrett Rosenberg; Richard Luong; Teri Moore; Günter Lauritsch; Frandics Chan; David P Lee; Rebecca Fahrig
Journal:  Invest Radiol       Date:  2015-06       Impact factor: 6.016

2.  Intraprocedure visualization of the esophagus using interventional C-arm CT as guidance for left atrial radiofrequency ablation.

Authors:  Alessia Tognolini; Amin Al-Ahmad; Paul J Wang; Henry H Hsia; Robert J Herfkens; Erin Girard; Teri Moore; Rebecca Fahrig
Journal:  Acad Radiol       Date:  2011-03-25       Impact factor: 3.173

3.  Contrast-enhanced C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle.

Authors:  Erin E Girard; Amin Al-Ahmad; Jarrett Rosenberg; Richard Luong; Teri Moore; Günter Lauritsch; Jan Boese; Rebecca Fahrig
Journal:  JACC Cardiovasc Imaging       Date:  2011-03

4.  Practical patient dosimetry for partial rotation cone beam CT.

Authors:  E C Podnieks; I S Negus
Journal:  Br J Radiol       Date:  2011-02-08       Impact factor: 3.039

5.  Reducing radiation exposure during invasive coronary angiography and percutaneous coronary interventions implementing a simple four-step protocol.

Authors:  Moritz Seiffert; Francisco Ojeda; Kai Müllerleile; Elvin Zengin; Christoph Sinning; Christoph Waldeyer; Edith Lubos; Ulrich Schäfer; Karsten Sydow; Stefan Blankenberg; Dirk Westermann
Journal:  Clin Res Cardiol       Date:  2015-01-22       Impact factor: 5.460

6.  The effective dose assessment of C-arm CT in hepatic arterial embolisation therapy.

Authors:  Y-S Tyan; Y-Y Li; M-C Ku; H-H Huang; T-R Chen
Journal:  Br J Radiol       Date:  2013-02-12       Impact factor: 3.039

Review 7.  The Growing Culture Of A Minimally Fluoroscopic Approach In Electrophysiology Lab.

Authors:  Michela Casella; Eleonora Russo; Francesca Pizzamiglio; Sergio Conti; Ghaliah Al-Mohani; Daniele Colombo; Victor Casula; Yuri D Alessandra; Viviana Biagioli; Corrado Carbucicchio; Stefania Riva; Gaetano Fassini; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Vittoria Marino; Giovanni Forleo; Pasquale Santangeli; Luigi Di Biase; Antonio Dello Russo; Andrea Natale; Claudio Tondo
Journal:  J Atr Fibrillation       Date:  2014-08-31

8.  Investigations of organ and effective doses of abdominal cone-beam computed tomography during transarterial chemoembolization using Monte Carlo simulation.

Authors:  Yi-Shuan Hwang; Hui-Yu Tsai; Yu-Ying Lin; Kar-Wai Lui
Journal:  BMC Med Imaging       Date:  2018-02-05       Impact factor: 1.930

9.  Combining Optimized Image Processing With Dual Axis Rotational Angiography: Toward Low-Dose Invasive Coronary Angiography.

Authors:  Dimitri Buytaert; Benny Drieghe; Frédéric Van Heuverswyn; Jan De Pooter; Peter Gheeraert; Daniël De Wolf; Yves Taeymans; Klaus Bacher
Journal:  J Am Heart Assoc       Date:  2020-07-01       Impact factor: 5.501

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.