Literature DB >> 23403454

The effective dose assessment of C-arm CT in hepatic arterial embolisation therapy.

Y-S Tyan1, Y-Y Li, M-C Ku, H-H Huang, T-R Chen.   

Abstract

OBJECTIVE: To assess the effective dose of the liver C-arm computed tomography (CT) scan during hepatic arterial embolisation surgery with clinical dose-area product (DAP) data from Taiwan.
METHODS: The experiment used two kinds of phantoms: RANDO® Man and RANDO Woman (The Phantom Laboratory, Salem, NY), embedded with thermoluminescent dosemeters at locations according to the International Commission on Radiological Protection 103 report. The conversion factors of DAP to effective doses for males and females, respectively, were obtained. The clinical DAP data of liver C-arm CT scan during hepatic arterial embolisation surgery were collected in a hospital in Taiwan.
RESULTS: There were 125 liver transarterial embolisation therapy cases, including 94 males and 31 females, from February 2009 to June 2010. C-arm CT was used 38 times for males and 17 times for females. The corresponding average and standard deviation of clinical DAP were 61.0±6.6 Gy cm(2) and 52.2±8.3 Gy cm(2), respectively.
CONCLUSION: The DAP of RANDO Man and RANDO Woman phantoms simply scanned by C-arm CT are much lower than that of patients. After consideration of the clinical DAP of patients, the effective doses of a liver C-arm CT scan recommended for males and females in Taiwan are 11.5±2.3 mSv and 11.3±3.0 mSv, respectively. ADVANCES IN KNOWLEDGE: The conversion factors of DAP to effective doses for males and females are 0.19±0.03 mSv Gy(-1) cm(-2) and 0.22±0.05 mSv Gy(-1) cm(-2). Only if the actual DAP value of a patient scan is multiplied by the conversion factor can the correct effective dose be determined.

Entities:  

Mesh:

Year:  2013        PMID: 23403454      PMCID: PMC3635788          DOI: 10.1259/bjr.20120551

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  13 in total

1.  Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.

Authors:  Lisa Duggan; Claire Hood; Helen Warren-Forward; Mamoon Haque; Tomas Kron
Journal:  Phys Med Biol       Date:  2004-09-07       Impact factor: 3.609

2.  The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): a phantom study.

Authors:  Mei Bai; Bin Liu; Hongqiu Mu; Xianghua Liu; Yuan Jiang
Journal:  Eur J Radiol       Date:  2011-10-02       Impact factor: 3.528

3.  C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules.

Authors:  Hye Sun Hwang; Myung Jin Chung; Ju Won Lee; Sung Wook Shin; Kyung Soo Lee
Journal:  AJR Am J Roentgenol       Date:  2010-12       Impact factor: 3.959

Review 4.  Flat-detector computed tomography (FD-CT).

Authors:  Willi A Kalender; Yiannis Kyriakou
Journal:  Eur Radiol       Date:  2007-06-23       Impact factor: 5.315

Review 5.  C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology.

Authors:  Robert C Orth; Michael J Wallace; Michael D Kuo
Journal:  J Vasc Interv Radiol       Date:  2008-04-23       Impact factor: 3.464

Review 6.  Three-dimensional C-arm cone-beam CT: applications in the interventional suite.

Authors:  Michael J Wallace; Michael D Kuo; Craig Glaiberman; Christoph A Binkert; Robert C Orth; Gilles Soulez
Journal:  J Vasc Interv Radiol       Date:  2008-04-10       Impact factor: 3.464

7.  The tissue-equivalence of the Alderson Rando anthropomorphic phantom for x-rays of diagnostic qualities.

Authors:  P C Shrimpton; B F Wall; E S Fisher
Journal:  Phys Med Biol       Date:  1981-01       Impact factor: 3.609

8.  Active bone marrow distribution in the adult.

Authors:  W J Russell; S Antoku; M Mizuno
Journal:  Br J Radiol       Date:  1966-10       Impact factor: 3.039

9.  Global cancer statistics.

Authors:  Ahmedin Jemal; Freddie Bray; Melissa M Center; Jacques Ferlay; Elizabeth Ward; David Forman
Journal:  CA Cancer J Clin       Date:  2011-02-04       Impact factor: 508.702

10.  Effective dose analysis of three-dimensional rotational angiography during catheter ablation procedures.

Authors:  J-Y Wielandts; K Smans; J Ector; S De Buck; H Heidbüchel; H Bosmans
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

View more
  1 in total

Review 1.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.