Mechanical evaluation of large-size fourth-generation composite femur and tibia models.

Matthew P Gardner1, Alexander C M Chong, Anthony G Pollock, Paul H Wooley.   

Abstract

Composite analogue bone models provide consistent geometric and structural properties that represent a valuable asset in a range of biomechanical analyses and testing procedures. The objective of this study was to evaluate the diaphyseal structural properties of the large-size Fourth-Generation composite analogue femur and tibia models concentrated on mechanical behaviors under axial compression, bending and torsion. Thirty of each large-size composite analogue models (femora and tibiae) were tested under medial-lateral four-point bending, anterior-posterior four-point bending, axial compression and external rotational torque to evaluate flexural rigidity, axial stiffness, torsional rigidity and ultimate failure strength. The composite femur was tested under torsion at both the femoral neck and the mid-diaphyseal areas. Large-size Fourth-Generation composite replicate bones exhibited intra-specimen variations under 10% for all cases and was also found to perform within the biological range of healthy adult bones (age: <80 years old) range with respect to flexural rigidity (<8%) and torsional rigidity (<12%). The failure modes of these composite models were close to published findings for human bones (four-point bending: butterfly fragment fracture; torsional: spiral fracture; and compression: transverse fracture). The large-size composite analogue femur and tibia are close to ideal replicas for standardization in biomechanical analyses. One advantage of these analogue models is that their variability is significantly lower than that of cadaveric specimens for all loading regimens. Published results vary widely in cadaveric studies, which is likely due to the high anatomic variability among cadaveric specimens. This study evaluated and advanced our overall understanding of the capacity of composite analogue bone models mimic the structural properties of average healthy adult human bones.

Entities:  

Mesh:

Year:  2010        PMID: 20049637     DOI: 10.1007/s10439-009-9887-7

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  52 in total

1.  Inversion of the acetabular labrum causes increased localized contact pressure on the femoral head: a biomechanical study.

Authors:  Xipeng Wang; Kiyokazu Fukui; Ayumi Kaneuji; Kenichi Hirosaki; Hiroyasu Miyakawa; Norio Kawahara
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

2.  A new angle stable nailing concept for the treatment of distal tibia fractures.

Authors:  Sebastian Kuhn; Philipp Appelmann; Philip Pairon; Dorothea Mehler; Frank Hartmann; Pol M Rommens
Journal:  Int Orthop       Date:  2014-01-09       Impact factor: 3.075

3.  Improved stability with intramedullary stem after anterior femoral notching in total knee arthroplasty.

Authors:  A Completo; F Fonseca; C Relvas; A Ramos; J A Simões
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-06-01       Impact factor: 4.342

4.  Comparative assessment of different reconstructive techniques of distal femur in revision total knee arthroplasty.

Authors:  A Completo; F Fonseca; A Ramos; J Simões
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-05-30       Impact factor: 4.342

5.  Pullout Strength After Multiple Reinsertions in Radial Bone Fixation.

Authors:  Alfonso Mejia; Giovanni Solitro; Elena Gonzalez; Amit Parekh; Mark Gonzalez; Farid Amirouche
Journal:  Hand (N Y)       Date:  2018-09-06

6.  Mechanical evaluation of fourth-generation composite femur hybrid locking plate constructs.

Authors:  Tarun Goswami; Vinit Patel; David J Dalstrom; Michael J Prayson
Journal:  J Mater Sci Mater Med       Date:  2011-07-17       Impact factor: 3.896

7.  Association of the Anterolateral Thigh Osteomyocutaneous Flap With Femur Structural Integrity and Assessment of Prophylactic Fixation.

Authors:  Mitchell L Worley; Travis M Patterson; Evan M Graboyes; Yongren Wu; Robert M Brody; Joshua Hornig; Zeke Walton
Journal:  JAMA Otolaryngol Head Neck Surg       Date:  2018-09-01       Impact factor: 6.223

8.  A Biomechanical Comparison Of Pin Configurations Used For Percutaneous Pinning Of Distal Tibia Fractures In Children.

Authors:  Justin Brantley; Aditi Majumdar; J Taylor Jobe; Antony Kallur; Christina Salas
Journal:  Iowa Orthop J       Date:  2016

9.  Stability of mid-shaft clavicle fractures after plate fixation versus intramedullary repair and after hardware removal.

Authors:  Sean D Smith; Coen A Wijdicks; Kyle S Jansson; Robert E Boykin; Frank Martetschlaeger; Peter-Paul de Meijer; Peter J Millett; Tom R Hackett
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-01-31       Impact factor: 4.342

10.  Are quadrilateral surface buttress plates comparable to traditional forms of transverse acetabular fracture fixation?

Authors:  Brian J Kistler; Ian R Smithson; Seth A Cooper; Jacob L Cox; Aniruddh N Nayak; Brandon G Santoni; H Claude Sagi
Journal:  Clin Orthop Relat Res       Date:  2014-11       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.