PURPOSE: Surgical treatment of distal tibial fractures demands a stable fracture fixation while minimizing the irritation to the soft tissues by approach and implant. Biomechanical studies have demonstrated superior performance for angular-stable locked nails over standard locked nails in distal tibial fractures. The experimental Retrograde Tibial Nail (RTN) is a minimally invasive local intramedullary osteosynthesis, which has been under design by our group. We conducted a biomechanical comparison in composite tibiae of the Retrograde Tibial Nail against the Expert Tibial Nail (Synthes®). Our hypothesis was that the RTN would provide equivalent biomechanical stability with respect to extra-axial compression, torsion and load to failure testing, in an extra-articular distal tibia fracture model. METHODS: Biomechanical composite bone testing was conducted in 14 biomechanical composite tibiae in an AO 43 A3 fracture model. In both groups, triple angle stable interlocking was performed in the distal fragment. RESULTS: Results show a statistically non-significant higher stability of the ETN during the axial loading tests. Torsional stability testing resulted in a statistically superior performance for the RTN (p = 0.018). Destructive extra-axial compression resulted in failure of six ETN constructs, while all RTN specimens survived the maximal load. CONCLUSIONS: The experimental Retrograde Tibial Nail provides the key features for the treatment of distal tibial fractures. It combines a minimally invasive local intramedullary osteosynthesis with the ability to securely fix the fracture by multiple angle stable locking options.
PURPOSE: Surgical treatment of distal tibial fractures demands a stable fracture fixation while minimizing the irritation to the soft tissues by approach and implant. Biomechanical studies have demonstrated superior performance for angular-stable locked nails over standard locked nails in distal tibial fractures. The experimental Retrograde Tibial Nail (RTN) is a minimally invasive local intramedullary osteosynthesis, which has been under design by our group. We conducted a biomechanical comparison in composite tibiae of the Retrograde Tibial Nail against the Expert Tibial Nail (Synthes®). Our hypothesis was that the RTN would provide equivalent biomechanical stability with respect to extra-axial compression, torsion and load to failure testing, in an extra-articular distal tibia fracture model. METHODS: Biomechanical composite bone testing was conducted in 14 biomechanical composite tibiae in an AO 43 A3 fracture model. In both groups, triple angle stable interlocking was performed in the distal fragment. RESULTS: Results show a statistically non-significant higher stability of the ETN during the axial loading tests. Torsional stability testing resulted in a statistically superior performance for the RTN (p = 0.018). Destructive extra-axial compression resulted in failure of six ETN constructs, while all RTN specimens survived the maximal load. CONCLUSIONS: The experimental Retrograde Tibial Nail provides the key features for the treatment of distal tibial fractures. It combines a minimally invasive local intramedullary osteosynthesis with the ability to securely fix the fracture by multiple angle stable locking options.
Authors: Julia Greenfield; Philipp Appelmann; Yoann Lafon; Karine Bruyère-Garnier; Pol Maria Rommens; Sebastian Kuhn Journal: Sci Rep Date: 2021-09-22 Impact factor: 4.379
Authors: Julia Greenfield; Philipp Appelmann; Felix Wunderlich; Dorothea Mehler; Pol Maria Rommens; Sebastian Kuhn Journal: Eur J Trauma Emerg Surg Date: 2021-12-03 Impact factor: 2.374
Authors: Sebastian Kuhn; Philipp Appelmann; Dorothea Mehler; Philip Pairon; Pol M Rommens Journal: J Orthop Surg Res Date: 2014-05-13 Impact factor: 2.359